Contact Us

LTC4418CUF#TRPBF

Brand: Analog Devices
Analog Devices LTC4418CUF#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC4418CUF#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC4418CUF#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC4418CUF#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC4418CUF#TRPBF: two supplies, one output, and a 1.5 percent window that decides when to switch

The LTC4418CUF#TRPBF is an Analog Devices dual channel prioritized PowerPath controller. It connects one of two valid supplies to a common output, with V1 as the higher priority input and V2 as the lower one. A supply counts as valid when its voltage has stayed inside its overvoltage and undervoltage window for the configured validation time, so a short dip or spike does not cause a switch. It works from 2.5 V to 40 V, survives a reverse connection down to -42 V, tolerates 60 V on the V1 and V2 pins, blocks both reverse and cross conduction, and draws 26 uA. The overvoltage and undervoltage thresholds are accurate to plus or minus 1.5 percent with adjustable hysteresis. Multiple parts, and the triple channel LTC4417, can be cascaded for more than two inputs. It is the 20-lead 4 mm by 4 mm QFN, and it sits with the rest of the power line on the analog and mixed-signal IC line card.

Plus or minus 1.5 percent is 180 mV on a 12 V rail

An accuracy of 1.5 percent translates into a different window on every rail. On a 5 V rail it is 75 mV, on 12 V it is 180 mV, and on 24 V it is 360 mV. That is the band between the point where the input is still considered good and the point where the part switches away, so it has to be narrower than the tolerance of the upstream supply plus the drop in the wiring. A 12 V supply held to plus or minus 5 percent already swings 600 mV, which is more than three times the window, so the divider on the OV and UV pins has to be set inside that swing rather than at its nominal value.

ParameterVendor figureDerived figure
Operating range2.5 V to 40 Vone part across 5 V, 12 V and 24 V rails
Threshold accuracyplus or minus 1.5 percent75 mV at 5 V, 180 mV at 12 V, 360 mV at 24 V
Input tolerance60 V on V1 and V2survives a transient above the rail
Reverse protectionto -42 Vcovers a reversed battery connection
Operating current26 uA0.62 mW at 24 V, 1.04 mW at 40 V
Switchoverfast non-overlapoutput droop limited by the load capacitance
Expansioncascadable with the LTC4417three or more inputs

The validation time is what separates a brownout from a real failure

A supply that dips for a few hundred microseconds during a load step is not a failed supply, and switching to the backup for that dip costs more than riding through it. The adjustable input validation time sets how long a rail must stay inside its window before it is accepted, so a short excursion is ignored and a real loss is acted on. The cost of a long validation time is a longer gap before the backup is trusted, which has to be covered by the output capacitance. That trade is the single most useful adjustment on this part and it is set by one external component.

Selection notes

  • Cross conduction blocking means both inputs can be live at the same time without one feeding the other through the body diodes.
  • The -42 V reverse rating covers a battery inserted the wrong way, which is a common field event on portable equipment.
  • Cascading more than two inputs uses the same part, so the priority chain is extended without a second controller type.
  • Hysteresis on the OV and UV comparators prevents the output from chattering when a supply sits exactly at the threshold.

Questions buyers ask

Does it switch fast enough to hold up a rail without a large capacitor? The switchover is non-overlap and fast, but the droop is set by the load current and the output capacitance, so the hold-up capacitor is sized from the load step and the switchover time, not from the controller alone.

Can both inputs be the same voltage? Yes, priority is set by pin assignment, so two identical rails are handled by which pin they enter.

Second sourcing a power path controller across a board is covered on the power management cross reference page, and delivery on allocated parts is under BOM shortage recovery.

Request Quote — In Stock, 100% New & Original, Full Warranty