LT3065EMSE
Product Specifications
LT3065EMSE
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3065EMSE from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3065EMSE: 45 V In and 500 mA Out Is 21 W of Heat Before It Is a Current Rating
The LT3065 is a 500 mA low dropout regulator that runs from 1.6 V to 45 V, with 300 mV of dropout at full load, 25 uV rms of noise over the 10 Hz to 100 kHz band, a programmable current limit accurate to 10 percent and a power good flag. The input range and the current rating are both real, but they do not add up to a free 500 mA at 45 V: regulating 3.3 V from 45 V at 500 mA means the pass device turns 20.85 W into heat, and the 12-lead MSOP body in the MSE code has no way to move that. The current rating is a thermal statement at a stated input voltage, and the useful table is dissipation against input voltage.
The programmable current limit is the feature that earns its place
A single resistor from the IMAX pin to ground sets the current limit, and the accuracy of that limit is quoted at 10 percent over input voltage and temperature. That turns the regulator into a two terminal current source good enough for a sensor loop or a battery charge path, and it also protects the upstream supply from a fault downstream. With a 1.5 kohm resistor the limit lands near 200 mA, which is the example in the data sheet, and the internal foldback limit at 900 mA is what takes over if the resistor is left open.
| Input to output | Dissipation at 500 mA | Dissipation at 200 mA |
|---|---|---|
| 45 V to 3.3 V | 20.85 W | 8.34 W |
| 24 V to 3.3 V | 10.35 W | 4.14 W |
| 12 V to 3.3 V | 4.35 W | 1.74 W |
| 12 V to 5 V | 3.50 W | 1.40 W |
| 5.5 V to 3.3 V | 1.10 W | 0.44 W |
Dropout and the minimum input voltage
Dropout is 300 mV typical at 500 mA and 110 mV to 150 mV at 10 mA, so a 3.3 V output needs about 3.6 V at full load and rather less when the load is light. The published minimum input voltage at 500 mA is 1.6 V to 2.2 V, which applies to the low voltage fixed options and not to a 3.3 V output. A rail that sits at 5 V nominal with 5 percent tolerance is 4.75 V at the low end, which leaves 1.15 V of margin over the 3.6 V requirement, so that combination is safe. A 3.3 V rail feeding a 3.3 V output is not something this part can rescue.
Noise, the bypass capacitor and the power good flag
The 25 uV rms noise figure assumes the reference bypass capacitor is fitted, and that same capacitor also sets the soft start ramp: one pin does both jobs, and removing the capacitor to save a component raises the noise and removes the ramp. Power good has 1.6 percent of hysteresis on the trip point, which is what stops the flag from chattering at the threshold, and its open drain output needs a pull up to a rail the downstream logic can accept. Shutdown current is quoted below 1 uA, so a rail that is not needed can be parked without a load switch.
Where the current rating actually lands
From 12 V to 3.3 V at 500 mA the 4.35 W is already beyond a 12-lead MSOP without a thermal pad and a copper pour, so the practical answer is 200 mA at that input voltage, or a two stage drop with a switching regulator in front. The power management cross reference page covers the regulator class, the how to reduce component cost page covers the two stage alternative, and incoming checks follow the incoming inspection plan.