Contact Us

LTC4380IMS-2#TRPBF

Brand: Analog Devices
Analog Devices LTC4380IMS-2#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC4380IMS-2#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC4380IMS-2#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC4380IMS-2#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC4380IMS-2#TRPBF: A Surge Stopper That Spends 8 uA, and Where the Transient Energy Actually Lands

The LTC4380IMS-2#TRPBF is a low quiescent current surge stopper that protects a load from high voltage transients by controlling the gate of an external N-channel MOSFET. The operating range is 4 V to 72 V, the gate clamp is selectable at 31.5 V for 12 V systems or 50 V for 24 V and 28 V systems, and adjustable clamp versions cover any system up to 72 V. Reverse input protection extends to minus 60 V by driving back to back MOSFETs, which removes the forward drop and the dissipation of a Schottky diode. Operating current is 8 uA and the ON pin comparator drops that to 6 uA while doubling as an undervoltage monitor and a shutdown input. An internal multiplier generates a timer current proportional to the drain to source voltage and the drain current, so the fault timer follows the stress in the MOSFET rather than a fixed clock. Latchoff and retry options are both offered, the part is AEC-Q100 qualified, and the body is a 10-pin 3 mm by 3 mm DFN or an MSOP.

The reason a surge stopper exists rather than a transient suppressor is that a clamp diode converts a surge into heat at the diode, with no control over how much current flows. A surge stopper converts the surge into heat in a MOSFET whose safe operating area the engineer can read from a data sheet, and it can turn the load off when the surge lasts too long.

Sixty volts clamped to 31.5 V at one amp is 28.5 W in the pass device

During a load dump the input rises and the gate clamp holds the source at 31.5 V, so the difference appears across the MOSFET. At 60 V in and 1 A of load that is 28.5 W, and at 5 A it is 142.5 W. The MOSFET survives this only because the event is short, and the timer is what guarantees it stays short: the multiplier makes the timer run faster when the voltage across the device is higher, so a 70 V event is cut off sooner than a 40 V event at the same current.

The choice of clamp voltage is a system decision. A 12 V system with a 31.5 V clamp gives the load 19.5 V of headroom above nominal, which most 12 V loads do not want to see but can survive for the duration of the timer. A 24 V system with a 50 V clamp has 26 V of headroom, and the 72 V ceiling of the part covers a 48 V rail with margin for a transient.

8 uA of operating current is 96 uW at 12 V and 70 mAh over a year

An always-on protection circuit that draws a milliamp is an engineering problem in a vehicle that sits for weeks. At 8 uA and 12 V the part draws 96 uW, and over a year that is 70 mAh, which is a rounding error against a 60 Ah battery. The 6 uA shutdown state, reached through the ON pin, is 52.6 mAh over a year, and the same pin serves as the undervoltage monitor, so the load is disconnected below the threshold rather than being allowed to drain the battery through its own input capacitance.

Reverse protection to minus 60 V is the other always-on case. A Schottky diode in series with a 5 A load drops 0.4 V and dissipates 2 W continuously; two back to back MOSFETs controlled by this part drop tens of millivolts and dissipate a fraction of a watt, and the difference is a heatsink that does not have to be fitted.

The -2 suffix is the retry behaviour, not a different voltage

The family offers latchoff and retry versions, and the retry version restarts after a cool down with a low duty cycle so a persistent fault does not turn into a continuous thermal load. For an automotive module the retry version means the load comes back when the transient passes without a human cycling the ignition; the latchoff version means a fault is latched until the controller resets it.

The adjustable clamp versions matter for any rail above 28 V, where neither fixed clamp matches the system. The gate clamp is set by an external divider, so the divider tolerance is part of the clamp accuracy and has to be added to the MOSFET voltage rating when the part is chosen.

FunctionSurge stopper and overvoltage protection controller for an external N-channel MOSFET
Operating range4 V to 72 V, reverse protection to minus 60 V
Gate clamp31.5 V for 12 V systems, 50 V for 24 V and 28 V systems, or adjustable
Quiescent current8 uA operating, 6 uA in shutdown through the ON pin, 70 mAh over a year at 12 V
Fault timerCurrent proportional to drain to source voltage and drain current
Dissipation example60 V clamped to 31.5 V at 1 A is 28.5 W in the pass device
OvercurrentProtected with the same stress tracking timer
OptionsLatchoff and retry variants, fixed and adjustable clamp
QualificationAEC-Q100 for automotive applications
Package10-pin DFN 3 mm by 3 mm or MSOP, order code IMS-2
LifecycleListed by the vendor as recommended for new projects

Two questions buyers ask

Is the 31.5 V clamp safe for a 12 V load rated at 16 V?
The clamp limits the output during a transient and does not hold it there forever: the timer ends the event. A load rated at 16 V that sees 31.5 V for the length of the timer is outside its absolute maximum, so the clamp voltage has to be chosen against the load rating as well as against the MOSFET. For a 16 V load the adjustable version set closer to 20 V is the honest choice, with a MOSFET rated for the full 60 V input.

Does the multiplier timer protect the MOSFET or the load?
The MOSFET. The timer runs faster when the voltage across the device and the current through it are larger, which tracks the instantaneous stress and keeps the device inside its safe operating area. The load sees whatever the clamp allows for the duration, so the two protections are separate concerns and both have to be checked.

Ordering and supply

The IMS suffix is the MSOP body in the industrial temperature grade and the -2 is the retry behaviour. The AEC-Q100 parts carry the automotive grade suffix, and a project that has to file a functional safety case needs the automotive order code rather than the industrial one, since the qualification paperwork follows the code.

We hold this controller for automotive and industrial builds. The analog mixed signal ICs page lists the protection parts we carry, power management cross reference is where an existing TVS plus diode arrangement is compared against a controlled surge stopper, and where a module is being re-sourced, BOM shortage recovery covers the parts around the controller that have to match its rating.

Request Quote — In Stock, 100% New & Original, Full Warranty