LTC4368IMS-2#TRPBF
Product Specifications
LTC4368IMS-2#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC4368IMS-2#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4368IMS-2#TRPBF: a 100 V window, a 3 mV reverse threshold and a circuit breaker in both directions
The LTC4368IMS-2#TRPBF is an Analog Devices protection controller that guards a load against supplies that are too high, too low or reversed, and against overcurrent in both directions. It drives the gates of a pair of back-to-back N-channel MOSFETs so the load is connected only when there is no voltage or current fault. Operating range is 2.5 V to 60 V, overvoltage protection reaches 100 V, reverse supply protection reaches -40 V, and the undervoltage and overvoltage thresholds are accurate to plus or minus 1.5 percent with external resistors setting the set points. Operating current is 80 uA and shutdown current is 5 uA. The -2 variant sets the reverse circuit breaker threshold at -3 mV, while the -1 variant uses -50 mV. A 32 ms turn-on delay debounces a live supply connection. It is available in a 10-pin MSOP and a 3 mm by 3 mm DFN and is AEC-Q100 qualified. It is on the analog and mixed-signal IC line card.
The -1 and the -2 differ by 47 mV, and that decides the application
The reverse current threshold is what the circuit breaker treats as a fault in the reverse direction. With a 2 milliohm sense resistor, the -1 threshold of 50 mV means 25 A of reverse current is allowed before it trips, which suits a system where the load can briefly push current back, such as a motor that regenerates. The -2 threshold of 3 mV means 1.5 mA trips it, which suits a load that must never feed the input, such as a battery-backed rail. Ordering the wrong variant is a behavioural difference, not a tolerance difference, and both are in the same datasheet.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Operating range | 2.5 V to 60 V | one part for 12 V, 24 V and 48 V rails |
| Overvoltage protection | to 100 V | survives a transient above the operating range |
| Reverse protection | to -40 V | covers a reversed supply connection |
| Threshold accuracy | plus or minus 1.5 percent | 180 mV at 12 V, 360 mV at 24 V, 720 mV at 48 V |
| Forward breaker | 50 mV across the sense resistor | 25 A with 2 milliohm |
| Reverse breaker | -50 mV on -1, -3 mV on -2 | 1.5 mA with 2 milliohm on the -2 |
| Operating current | 80 uA, 5 uA shutdown | 3.84 mW at 48 V |
Blocking 50 and 60 Hz is an unusual capability worth understanding
The back-to-back MOSFET pair lets the part block an AC supply within its voltage rating, which is what allows it to sit on an input that can be either polarity or can carry mains frequency ripple. A single MOSFET would conduct through its body diode in one direction, so the pair is what makes the block bidirectional. The 32 ms turn-on delay then debounces the connection, so a connector that bounces on insertion does not produce a series of inrush events.
Selection notes
- The undervoltage and overvoltage set points come from an external divider, so the plus or minus 1.5 percent accuracy applies to the comparator while the divider tolerance adds to it.
- After a reverse current fault the part waits for the output to fall 100 mV below the input before reconnecting, which prevents oscillation at the fault point.
- Pin selectable auto-retry or latchoff after an overcurrent fault is a policy choice: retry for unattended equipment, latch for equipment that must be inspected.
- The 100 V overvoltage rating is the transient capability, not the continuous operating voltage, and the two are often confused when a 48 V system is specified.
Questions buyers ask
Does it replace a fuse? It replaces the fuse with a resettable breaker and adds voltage window protection. Where a standard requires a physical fuse, the controller does not remove that requirement.
Can the MOSFETs be shared with a load switch? The pair is chosen for the current and the thermal path, and the controller sets the gate drive, so the FET selection is driven by the fault current and the on resistance rather than by the controller alone.
Protection controllers are a common substitution item on industrial boards, and the checks are on how to verify a drop in replacement. The family is on the power management cross reference page.
Request Quote — In Stock, 100% New & Original, Full Warranty