Contact Us

LTC4365IDDB#TRPBF

Brand: Analog Devices
Analog Devices LTC4365IDDB#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC4365IDDB#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC4365IDDB#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC4365IDDB#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC4365IDDB#TRPBF: Overvoltage, Undervoltage and Reverse Protection in a 3 mm by 2 mm Package

The LTC4365IDDB#TRPBF is an overvoltage, undervoltage and reverse supply protection controller operating from 2.5 V to 34 V, with overvoltage protection to 60 V, reverse supply protection to minus 40 V, adjustable undervoltage and overvoltage thresholds, a charge pump that enhances an external N-channel MOSFET, a 36 ms turn-on delay that debounces a live connection and blocks 50 Hz and 60 Hz AC power, a 125 uA operating current, a 10 uA shutdown current, and an 8-lead 3 mm by 2 mm DFN package, also available in a TSOT-23. It is AEC-Q100 qualified for automotive applications and recommended for new designs, and the LTC4365-1 is the version with a 1 ms recovery after a fault.

This is the part that sits between a connector and the rest of the board and decides whether the voltage arriving is acceptable. It is not a surge stopper: it switches a FET on when the input is inside the window and off when it is not, and the difference between the two functions is whether the excess is dropped in series or simply disconnected.

Thirty six milliseconds blocks a 50 Hz mains connection, and that is deliberate

A 50 Hz supply has a 10 ms half cycle, so a 36 ms delay is 3.6 half cycles, and a connector that is plugged into an AC source never gets far enough to switch the FET on. At 60 Hz the half cycle is 8.33 ms and the ratio is 4.3. The delay is therefore not only a debounce for contact bounce, which lasts a few milliseconds, but a discrimination against the wrong kind of supply, and that is a feature for a product whose input connector is the same type as a mains connector on another product in the same family.

The 34 V operating ceiling against a 24 V rail at plus 10 percent is 26.4 V, which leaves 7.6 V of headroom, so a 24 V industrial rail is comfortable. Overvoltage protection extends to 60 V, which covers the transient the rail sees when a long cable is disconnected, and the controller turns the FET off rather than trying to absorb the event. Where the transient has real energy behind it, a surge stopper is the right part and this one is the disconnection.

FunctionOvervoltage, undervoltage and reverse supply protection controller
Operating range2.5 V to 34 V, with 7.6 V of headroom on a 24 V rail at plus 10 percent
OvervoltageProtection to 60 V, FET switched off
ReverseProtection to minus 40 V
Turn-on delay36 ms, 3.6 half cycles of 50 Hz and 4.3 of 60 Hz
AC blockingBlocks 50 Hz and 60 Hz mains on the input
Operating current125 uA, 1.5 mW at 12 V, 1.1 Ah over a year
Shutdown current10 uA, 88 mAh over a year
Fast recovery1 ms on the LTC4365-1, 36 ms on this part
Package8-lead 3 mm by 2 mm DFN as DDB, TSOT-23 in the family

One hundred and twenty five microamps is 1.1 amp hours a year

At 12 V the controller draws 1.5 mW, and over a year that is 1.1 Ah, which is more than half of a 2000 mAh pack. A protection stage that is always on therefore has to be justified in a battery product, and the 10 uA shutdown is the option that makes it affordable: a product that enables protection only when it is awake spends 88 mAh a year instead. The difference between the two figures is more than a factor of ten, and it is a firmware decision rather than a hardware one.

The undervoltage and overvoltage thresholds are set by a three resistor divider, and that divider draws current continuously whether the controller is awake or not. A divider of a few hundred kiloohms draws tens of microamps, which in a product built around a 125 uA controller is a significant fraction of the budget. The divider values are therefore part of the standby calculation, and a board that chooses them for accuracy alone usually finds the current is dominated by resistors rather than by the integrated circuit.

Two questions buyers ask

What is the difference between this and a surge stopper?
A surge stopper passes current and holds its output at a clamp level by dropping the excess across a FET, so the load stays powered through the event. This controller disconnects the load when the input leaves its window. For a short overvoltage that the downstream regulator can survive, disconnecting is simpler; for a long overvoltage that must not interrupt the load, the stopper is the right function.

Why does the fast recovery version exist?
Because 36 ms of recovery is long in a system that has to ride through a brief fault. The LTC4365-1 recovers in 1 ms, which keeps a downstream converter alive through a short interruption, at the cost of the AC blocking behaviour that the 36 ms delay provides. The two options are a choice between immunity to a wrong supply and tolerance of a short one.

Ordering and supply

The IDDB suffix is the 8-lead 3 mm by 2 mm DFN on the industrial grade and the TRPBF suffix is tape and reel. Traps are the recovery time, the divider values and the FET choice: a -1 part in a socket built for the 36 ms behaviour lets an AC input through, and a divider chosen for accuracy can draw more current than the controller. The external FET's gate charge also sets how fast the disconnect actually happens.

We hold and source this family for production and for repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where a protection controller has to be replaced in an existing product, the order in how to verify a drop in replacement puts the recovery time and the divider current ahead of the socket check.

Request Quote — In Stock, 100% New & Original, Full Warranty