AD8307ARZ
Product Specifications
AD8307ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD8307ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD8307ARZ: DC to 500 MHz Logarithmic Amplifier, 92 dB Range
The AD8307ARZ is a complete demodulating logarithmic amplifier in an 8-lead SOIC that covers DC to 500 MHz with 92 dB of dynamic range, from minus 75 dBm to plus 17 dBm, and to minus 90 dBm with an input matching network. The slope is 25 mV per dB, the intercept is minus 84 dBm, law conformance is 1 dB up to 100 MHz, and the signal path is fully differential and DC coupled, which is what allows operation down to 20 Hz as well as at radio frequency. It runs from 2.7 V to 5.5 V at 7.5 mA, powers up in 100 ns, and drops to 150 microamps in shutdown.
Published values
| Parameter | Value |
|---|---|
| Frequency range | DC to 500 MHz |
| Dynamic range | 92 dB, minus 75 dBm to plus 17 dBm |
| Extended range | To minus 90 dBm with a matching network |
| Slope | 25 mV per dB |
| Intercept | Minus 84 dBm |
| Law conformance | 1 dB up to 100 MHz |
| Signal path | Fully differential, DC coupled |
| Supply | 2.7 V to 5.5 V at 7.5 mA typical |
| Power up | 100 ns |
| Shutdown current | 150 microamps |
| Package | 8-lead SOIC |
Successive detection is why it works at 500 MHz
The part is built from nine detector cells spaced 14.3 dB apart, each one saturating in turn as the input rises, and the outputs are summed. That is the progressive compression technique: below the first cell's limit the sum is linear in decibels, and above the last cell the output flattens. The result is a piecewise approximation of a logarithm that holds to 1 dB over 92 dB, using a fraction of the current a true logarithmic amplifier would need. It also means the response time depends on the signal level: a small signal has to propagate through the chain with gain, and the rise time at the bottom of the range is microseconds rather than nanoseconds.
Slope, intercept and the calibration that follows
At 25 mV per dB, a 1 dB change is 25 mV at the output, so a 12-bit converter with a 2.5 V reference resolves 0.6 mV, or 0.024 dB. That sounds far better than the 1 dB conformance, and it is: the resolution is not the accuracy. The intercept of minus 84 dBm is where the extrapolated output would reach zero, and it is calibrated per part; the slope has a tolerance too. In a measuring instrument both are trimmed at two points, and the temperature drift of the slope, which is small but not zero, is what the remaining error budget has to cover. Adding a resistor from the output to ground reduces the slope, for systems that want a lower output level.
Input matching at the low end
The input resistance is 1.1 kohm, which is a poor match for a 50 ohm system. At high frequencies the mismatch costs a fraction of a decibel at the input and can be absorbed by the calibration. At the bottom of the range it costs more, because the matching network that transforms 50 ohm to 1.1 kohm also provides voltage gain, and that gain is what extends the range from minus 75 dBm to minus 90 dBm. Without the network the part still works, but the low end of the advertised range is not reachable. A simple LC network, or a transformer for narrow band use, is enough.
RSSI and the 100 ns power up
The 100 ns power up and 150 microamp shutdown make the part usable in a duty cycled receiver: switch it on, measure, switch it off. The measurement has to wait for the internal offset compensation loop to settle, which is longer than the power up time, and the datasheet gives the settling figure separately. In a radar or a time division system the sequence is power up, wait for settling, sample, power down, and the duty cycle then determines the average current. Treating the 100 ns as the total turn-on time is the mistake that produces readings that drift for the first few microseconds.
Availability and second sourcing
A log amplifier is defined by its slope, intercept and range, and a substitute with a different slope changes every calibration constant in the firmware. The amplifier cross reference page lists the logarithmic and detector parts by range, the ADI part second source page separates the parts with the same 25 mV per dB convention, and the obsolete part hub is where to look for a later part with the same function.