The LTC4357CDCB#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4357CDCB#TRPBF: An Ideal Diode Controller That Replaces 5 W of Schottky With 1 W
The LTC4357CDCB#TRPBF is a positive high voltage ideal diode controller that drives an external N-channel MOSFET to take the place of a power Schottky diode, operating over 9 V to 80 V with a 0.5 us turn-off time that limits peak fault current, smooth switchover without oscillation, and no reverse DC current. It is available in a 6-lead 2 mm by 3 mm DFN, which is this order code, and in an 8-lead MSOP, and it is recommended for new designs on the vendor site.
The arithmetic that sells the part is simple. A Schottky carrying 10 A drops about 0.5 V, which is 5 W of heat, and a MOSFET with 10 mOhm of on resistance at the same current drops 0.1 V and dissipates 1 W. The controller is the small part of that circuit; the saving is in the FET, the heatsink that is no longer needed, and the board area that the diode occupied.
Half a microsecond of turn-off decides the MOSFET, not the controller
When the input collapses or reverses, the controller has to turn the FET off before the reverse current builds. At 0.5 us and a fault current ramp of 100 A per microsecond, 50 A flows before the FET is off, and that current is what the MOSFET's safe operating area has to survive. The controller's timing is only half of that calculation: the gate charge of the chosen FET sets how fast it actually turns off, and a large FET with a 100 nC gate charge driven by the controller's output is slower than a small one. A board that picks the FET for its on resistance alone and ignores the gate charge ends up with a turn-off time several times the specification.
The 9 V minimum operating voltage is what rules the part out of a 5 V rail, and the 80 V ceiling covers a 48 V telecom rail with 32 V of headroom. Between those limits the controller works with any N-channel FET whose gate can be driven from the rail, and that is the second selection constraint: the FET has to be a logic level device for a 12 V rail and a standard device for a 48 V rail, and the controller's gate drive has to be checked against the FET's threshold and its absolute maximum gate voltage.
| Function | Ideal diode controller driving an external N-channel MOSFET |
| Voltage range | 9 V to 80 V, an 8.9 to 1 ratio |
| Turn-off time | 0.5 us, which limits the peak fault current |
| Reverse current | No reverse DC current |
| Schottky at 10 A | 0.5 V drop, 5 W of heat |
| MOSFET at 10 A | 10 mOhm, 0.1 V drop, 1 W of heat |
| At 20 A in the same FET | 200 mV drop and 4 W, so the saving narrows |
| Switchover | Smooth, without oscillation, for diode-OR and N plus 1 supplies |
| Packages | 6-lead 2 mm by 3 mm DFN as DCB, 8-lead MSOP as CMS |
| Status | Recommended for new designs |
Diode-OR is where the part earns its place, and where the FET choice matters most
In a redundant supply arrangement two sources feed one rail through two diodes, and the diode with the higher voltage takes the load. With Schottky diodes the current sharing is set by the forward voltage slope, and a 5 W diode on each of two supplies is a heatsink problem in a 1U chassis. With two controllers and two FETs the sharing is set by the FET resistances and the controller's loop, and the dissipation falls by a factor of five at 10 A. The switchover has to be smooth: an oscillation between the two paths produces a rail that wanders, and the controller's loop is specified for that case.
The saving narrows as current rises, because the MOSFET's dissipation grows with the square of the current while the Schottky's grows linearly. At 20 A in a 10 mOhm FET the drop is 200 mV and the dissipation 4 W, against 10 W for the Schottky, so the advantage is still 2.5 to 1 but the thermal problem has not disappeared. Below about 5 A the difference is small in absolute terms and the extra components may not be justified; the crossover is a board level calculation, not a rule.
Two questions buyers ask
Can it be used on a 5 V rail?
No. The minimum operating voltage is 9 V, so a 5 V rail needs a different controller from a lower voltage family. A 12 V rail is inside the range with 3 V of headroom, and a 48 V rail has 32 V.
What happens during a fast input collapse?
The controller turns the FET off in about 0.5 us, and the reverse current that flows in that window is set by the inductance of the path and the fault ramp. The FET has to survive that current for the duration, which is why the safe operating area curve and not the on resistance is the first page to read when choosing the device.
Ordering and supply
The CDCB suffix is the 6-lead 2 mm by 3 mm DFN on the commercial grade and the TRPBF suffix is tape and reel, lead free. Traps are the minimum operating voltage, the FET gate charge and the package: the MSOP version has two more pins and the same function, and a replacement controller with a 4 V minimum is a different part for a different rail. The FET is not in the order code but it decides whether the part meets its turn-off specification.
We hold and source this family for production and for repair. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where a controller has to be replaced in a redundant supply, the order in how to verify a drop in replacement puts the voltage range and the gate drive ahead of the socket check.