LTC4218IGN#TRPBF
Product Specifications
LTC4218IGN#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC4218IGN#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC4218IGN#TRPBF: A Hot Swap Controller With a 15 mV Current Limit and 100 mV of Headroom at 24 V
The LTC4218IGN#TRPBF is a hot swap controller that lets a board be inserted and removed from a live backplane. An internal high side driver controls the gate of an external N-channel MOSFET for supplies from 2.9 V to 26.5 V. The current limit sense voltage is 15 mV with 5 percent accuracy, adjustable through an external pin and with foldback, and a current monitor output amplifies the sense voltage for ground referenced measurement. There is an adjustable timer before a fault is declared, power good and fault outputs, adjustable inrush current control, and undervoltage and overvoltage comparators that are accurate to 2 percent. A dedicated 12 V version carries preset thresholds. The package is a 16-lead SSOP or a 16-pin 5 mm by 3 mm DFN, and this order code is the industrial grade SSOP.
The number to check first on a 24 V system is the 26.5 V ceiling. A 24 V rail at plus 10 percent is 26.4 V, which leaves 100 mV of margin. Anything that pushes the rail higher, including a transient that the upstream converter passes through, is outside the part.
Fifteen millivolts across the sense resistor sets the current, and the resistor is the accuracy
The current limit is a voltage across a resistor, so the resistor value sets the current. Fifteen millivolts across 2 milliohms is 7.5 A, across 5 milliohms it is 3 A, across 10 milliohms it is 1.5 A and across 20 milliohms it is 0.75 A. The 5 percent accuracy of the threshold is 150 mA on the 3 A case, so a 3 A limit is really 2.85 A to 3.15 A before the resistor tolerance is added. A 1 percent sense resistor with a 50 ppm per degree Celsius temperature coefficient contributes its own error on top.
The resistor also dissipates. At 3 A through 5 milliohms the sense resistor dissipates 45 mW, which is small, and at 7.5 A through 2 milliohms it is 112 mW, which needs a resistor of the right size rather than the smallest 0402 on the board. The current monitor output is the way to measure the load without adding a second shunt.
Inrush control is what stops the connector from welding
A board with 100 uF of input capacitance plugged into a live 24 V backplane draws whatever the capacitance and the resistance allow. The controller ramps the gate, so the MOSFET spends a controlled time in its linear region and the inrush is a set current rather than a spike. During that ramp the MOSFET dissipates the full input voltage times the inrush current, which at 26.4 V and 1 A is 26 W for the length of the ramp, and the safe operating area of the device is what the ramp time has to fit inside.
The adjustable timer before a fault allows a legitimate start-up into a large capacitance to complete without tripping, while a real short is still cut off. A hard short into a discharged rail and a legitimate start into 1000 uF look identical at the first microsecond, and the timer is the only thing that separates them.
Two percent undervoltage and overvoltage comparators protect the load as well as the board
A 2 percent threshold on a 24 V rail is 480 mV, which is tight enough to catch a brownout before the downstream converters drop out of regulation. The power good output feeds the enable of those converters, so the sequence is: insert, ramp, power good, converters start, and on removal the reverse order. A board without that sequence can have its converters start into an undervoltage rail and latch into a fault state.
The current monitor output is an analog voltage proportional to the load current, which is what a chassis manager uses to report per-slot power. That is a telemetry function rather than a protection function, and it is the reason the part appears in ATE and server systems rather than only in industrial cards.
| Function | Hot swap controller for an external N-channel MOSFET |
| Operating range | 2.9 V to 26.5 V, which leaves 100 mV on a 24 V rail at plus 10 percent |
| Current limit | 15 mV sense with 5 percent accuracy: 7.5 A at 2 milliohm, 3 A at 5, 1.5 A at 10, 0.75 A at 20 |
| Current monitor | Amplified sense output for ground referenced measurement |
| Timer | Adjustable limit timer before a fault is declared |
| Inrush | Adjustable ramp through the gate drive |
| Comparators | 2 percent accurate undervoltage and overvoltage, power good and fault outputs |
| Sense resistor loss | 45 mW at 3 A through 5 milliohm, 112 mW at 7.5 A through 2 milliohm |
| Package | 16-lead SSOP for this code, 16-pin 5 mm by 3 mm DFN also available |
| Lifecycle | Listed by the vendor as recommended for new projects |
Two questions buyers ask
What happens on a 28 V rail?
The part is outside its rating. The 26.5 V ceiling covers a 24 V rail at plus 10 percent with 100 mV to spare, and a 28 V nominal rail needs a controller with a higher ceiling rather than a clamp in front of this one, since a clamp that drops 2 V at the load current is a heater.
Is the 12 V version a drop-in for this one at 12 V?
It is the same function with preset thresholds, so it saves the divider and the comparator settings. The current limit and the timer are still set externally, and the preset thresholds are fixed, which is convenient for a 12 V backplane and wrong for a rail that is trimmed to 13.2 V.
Ordering and supply
The IGN suffix is the 16-lead SSOP in the industrial grade and the PBF suffix is the lead free finish. The DFN body is a separate code with a different thermal path, and the MOSFET beside it is chosen for its safe operating area at the ramp current, not for its on resistance alone.
We hold this controller for server, ATE and industrial builds. The analog mixed signal ICs page lists the hot swap and protection parts we carry, power management cross reference is where an existing hot swap part is compared against this one, and where a card is being moved to a new backplane, how to verify a drop in replacement puts the voltage ceiling and the sense threshold ahead of the footprint.
Request Quote — In Stock, 100% New & Original, Full Warranty