Contact Us

LTC3350EUHF#TRPBF

Brand: Analog Devices
Analog Devices LTC3350EUHF#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC3350EUHF#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC3350EUHF#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC3350EUHF#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC3350EUHF backup controller for a 12 V ride through rail

The LTC3350EUHF is a backup power controller that charges and monitors a stack of one to four supercapacitors from a 4.5 V to 35 V input, with a synchronous step down controller that runs in reverse as a step up converter during backup. It carries a 14-bit ADC behind an I2C and SMBus port that reports system voltages, currents, stack capacitance and stack ESR, and it does the cell balancing internally so no balance resistors are needed. The E letter is the temperature grade and the UHF suffix is the 38-lead 5 mm by 7 mm QFN.

The stack arithmetic that decides the size

Four 10 F cells in series are 2.5 F at a 10 V stack, which is 125 J. At a 300 W backup load that is 0.42 s if the stack could be taken to zero, which it cannot, so the real number is the energy between the top of the stack and the point where the converter stops:

StackEquivalent capacitanceEnergy at full stackEnergy from 10 V to 5 V
4 x 10 F, 10 V2.50 F125.0 J93.8 J
4 x 5 F, 10 V1.25 F62.5 J46.9 J
2 x 10 F, 5 V5.00 F62.5 J46.9 J

Two conclusions fall out of the table. First, capacitance in series divides, so the farad rating on a cell is not the stack capacitance. Second, halving the stack voltage quarters the energy for the same cells, which is why a 12 V ride through rail wants four cells in series rather than two.

Why the converter runs in reverse

A step down only charger stops delivering when the stack falls to the output rail, and on a 12 V rail that leaves more than half of the stored energy unused. Running the same inductor and FETs as a step up converter during backup lets the stack discharge below the rail, and the table shows the difference: 125 J down to zero against 93.8 J down to half the voltage. The extra 31 J is the reason the topology exists, and it is also why the inductor and the FETs have to be rated for the reverse direction.

What the telemetry actually measures

The ADC reports system voltages, currents, capacitance and ESR over the bus. Two of those are derived rather than measured: capacitance is computed from a timed charge or discharge, and ESR from the voltage step when the current changes. A 10 A step across 10 milliohms is 100 mV, which the 14-bit converter sees easily at 2.14 mV per code over a 35 V span, but the same converter is 305 uV per code over a 5 V span, so the resolution depends entirely on which channel and which divider. Read the scaling per channel before trusting a capacitance figure to better than a few percent.

Input current limit as a system protection

The programmable input current limit lets the system load take priority over the charge current, so a stack that is empty after a power cut recharges with whatever the input has left rather than pulling the rail down. That is the feature that makes the part usable on a 12 V rail that also feeds a disk or a radio: the charge current yields instead of competing.

ESR, capacitance, and what a field test looks like

Two of the four telemetry values are the ones that age: capacitance falls and ESR rises as a supercapacitor is cycled and as it sits at voltage. Neither is measured continuously, both are derived from a deliberate event. ESR comes from the voltage step when the current changes, and a 10 A step across 10 milliohms is 100 mV, which is easy to resolve. Capacitance comes from the slope of the voltage during a known current, and 10 A into a 2.5 F stack moves 4 V in one second, which is a large enough signal that the measurement does not need a precision reference.

The practical consequence is that a backup rail can be tested in the field without a load bank: the controller performs the same charge and discharge cycle that a service tool would, reports the two numbers over the bus, and the host compares them with the values recorded at commissioning. A rail that has lost 20 percent of its capacitance is a rail that will deliver 80 percent of the hold up time, and knowing that before the power fail is the whole point of the telemetry.

Questions that come up on this part

How long is the backup at 300 W? About 0.31 s from the usable energy of a 4 by 10 F stack between 10 V and 5 V. A longer window needs more capacitance, and the energy scales with the square of the stack voltage, so raising the stack helps more than adding cells in parallel.

Can it charge from a 24 V rail? Yes, the input range is 4.5 V to 35 V. A 48 V rail is outside the part and needs a different front end.

Does it need external balance resistors? No. The balancers are internal and each cell has a shunt regulator, which is what keeps a stack that sits charged for months from drifting.

Is the I2C port required for operation? No. The converter, the balancers and the PowerPath work without a host. The bus is for monitoring and for changing the charge current limit, so a board without a host still backs up correctly.

Sourcing notes and next step

Confirm the cell count, the stack voltage and the reverse mode requirement together, because a board that only needs buck backup does not need this part. Our power management cross reference page lists what we can quote against a code, the ADI second source page covers the alternatives, and the analog and mixed signal category holds the rest of the backup family.