LTC2872IUHF#TRPBF
Product Specifications
LTC2872IUHF#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC2872IUHF#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC2872IUHF four RS232 and two RS485 ports on shared pins
The LTC2872IUHF is a pin configurable multiprotocol transceiver that carries four RS232 transceivers and two RS485 transceivers on shared input output lines, from a single 3 V to 5.5 V supply. It handles RS232, RS485 and RS422, and the termination resistors that those standards need are inside the part and switched by a pin. The I letter is the temperature grade of this order code and the UHF suffix is the 38-lead 5 mm by 7 mm QFN.
One connector, three standards
The attraction is that a single port can be a four wire RS232 port on Monday and a two wire RS485 port on Tuesday without a relay or a rework. The 120 ohm RS485 termination and the 5 kohm RS232 input termination are selected automatically by the mode pins, so the board does not carry a bank of resistors and a set of jumpers. That matters most in a product where the same enclosure ships to customers who use different field buses, because the hardware is then one build instead of three.
| Item | Figure | What it means on a board |
|---|---|---|
| RS485 data rate | 20 Mbps | 50 ns per bit, four times faster than a 12 Mbps PROFIBUS bit at 83 ns |
| RS232 data rate | 500 kbps | 2 us per bit, the classic 3 wire port with room to spare |
| Nodes per bus | 256 | one eighth of a unit load each, against the 32 node reference load |
| ESD on line pins | plus or minus 16 kV | a pin cell figure, not a system level test result |
| Logic interface | 1.7 V to 5.5 V | 1.8 V logic can drive it without a level shifter |
Two hundred and fifty six nodes is a load budget
The RS485 standard is written around 32 unit loads, and a part that supports 256 nodes does it by presenting one eighth of a unit load at each receiver. The consequence is not that 256 nodes are practical on a long cable, it is that the driver sees eight times less loading per node, so a bus with 64 ordinary nodes and this part mixed in stays inside the drive current. Mixing parts on one bus is where the unit load number matters, and it has to be read from the receiver specification of every part on the wire, not assumed from the node count of the newest one.
The internal boost is what makes RS232 possible from 3.3 V
RS232 levels are plus and minus 5 V nominally, and a 3.3 V rail cannot make them directly. The part carries a DC to DC boost converter that needs a small inductor and one capacitor and generates the positive and negative rails internally. So a 3.3 V board gets a real RS232 port with no second supply and no charge pump circuit of its own. The cost is switching noise on a board that also has an analog front end, and the inductor placement is the part of the board that decides whether that noise stays inside the interface area.
Fail safe receivers and why a UART locks up
A floating or shorted RS485 pair has no defined differential voltage, and a receiver with a threshold near zero will oscillate on noise. The receivers here are full fail safe for floating, shorted and terminated but undriven inputs, which means the output stays at a defined idle level in all three cases. A UART that receives a stream of noise on an idle bus sees start bits that never end, which is the lockup this feature prevents. Loopback mode, which steers driver inputs to receiver outputs, is the diagnostic that proves the transceiver is alive before blaming the cable.
Where 35 square millimetres goes
Six transceivers, two termination networks and a boost converter in a 5 by 7 mm body is a high density, and the pin count is the reason the package is that size. The practical question is whether the board needs four RS232 ports at once, because a product that needs one RS485 port and one RS232 port is better served by the single bus part and the smaller body.
Thirty two unit loads, exactly
The RS485 standard is written around a reference load of 32 unit loads, and a 256 node part presents one eighth of a unit load at each receiver. Two hundred and fifty six times one eighth is exactly 32, so a full bus of this part is exactly at the reference load and no further. That is a clean way to check a mixed bus: convert every receiver to unit loads, add them, and the sum has to stay at or below 32. A bus with 200 nodes of this part and 20 older one unit load parts is 25 plus 20, which is 45 and outside the standard, even though the node count is only 220.
Questions that come up on this part
Can all six transceivers run at the same time? The part is configured by mode pins into a combination of RS232 and RS485 ports on shared lines. The combinations are defined by the strap table, so the answer to what runs simultaneously is in that table rather than in the pin names.
Does RS232 need a separate 5 V supply? No. The internal boost generates the positive and negative RS232 rails from the 3 V to 5.5 V supply using one inductor and one capacitor. That is the reason a 3.3 V board can present a real RS232 port.
Is the port isolated? No. Isolation is a separate barrier with its own part and its own creepage requirement, and the transceiver sits on one side of it.
What happens if the bus is disconnected? The receiver is full fail safe on floating, shorted and terminated but undriven inputs, so the output holds a defined idle level instead of oscillating on noise.
Sourcing notes and next step
Confirm the mode strap table against the firmware before ordering, because the port configuration is a pin state and a wrong strap is a silent misconfiguration rather than a failure. Our obsolete part cross reference hub covers the replacement route for older multiprotocol parts, the drop in replacement page covers the verification, and the analog and mixed signal category holds the rest of the interface family.
Request Quote — In Stock, 100% New & Original, Full Warranty