LT8640IUDC#TRPBF
Product Specifications
LT8640IUDC#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8640IUDC#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8640IUDC#TRPBF: the full minus 40 C guarantee in the 5 A regulator
The LT8640IUDC#TRPBF is the I grade of the 5 A, 42 V synchronous step-down regulator in the 18-lead 3 mm by 4 mm QFN. Where the E grade in this family is guaranteed from 0 C to 125 C junction with the cold end assured by characterisation, the I grade is guaranteed over the full minus 40 C to 125 C range. The electrical headline is unchanged: 3.4 V to 42 V input, 5 A continuous and 7 A peak transient, 2.5 uA burst mode, 30 ns minimum on time and 100 mV of dropout at 1 A.
The figures a cold climate build depends on
| Grade on this code | I, guaranteed minus 40 C to 125 C junction |
| E grade in the same family | guaranteed 0 C to 125 C, wider range by characterisation |
| Input range | 3.4 V to 42 V |
| Output current | 5 A continuous, 7 A peak transient |
| Quiescent current | 2.5 uA in burst mode |
| Reference and feedback | internal, 1 V enable threshold |
| Minimum on time | 30 ns |
| Frequency | 200 kHz to 3 MHz, synchronisable |
| Package | 18-lead 3 mm by 4 mm QFN |
Why the E to I step is not cosmetic
An outdoor unit that is stored at minus 40 C and started there is testing exactly the window the E grade only assures by characterisation. The difference is not a different silicon lot; it is the guarantee and the test coverage behind it. A product that must show a qualification report for a minus 40 C cold start should specify the I code, and a product that runs in a cabinet between 0 C and 70 C can use the E code and put the saving elsewhere. The two codes are separate order lines, so the choice has to be made at the bill of materials rather than at the loader.
Cold start also has a circuit consequence that the grade does not fix. At minus 40 C an aluminium electrolytic input capacitor can lose most of its capacitance and its ESR can rise by a factor of ten, so the input loop that was quiet at 25 C can ring at cold. A ceramic bank in parallel with the bulk part is the usual answer, and the 10 uF minimum the data sheet asks for at the input is a floor rather than a target when the board has to start cold.
Where the 30 ns floor and the 5 A rating meet
From 42 V to 3.3 V the duty cycle is 7.86 percent and the 30 ns floor caps the switching frequency at 2.62 MHz, so the common 2 MHz setting gives 39.3 ns of on time and works. From 42 V to 5 V the ceiling is about 3.97 MHz and the full 3 MHz range is usable. The 5 A figure is continuous; the 7 A figure is a transient rating. With a 1 uH inductor at 2 MHz from 12 V to 5 V the ripple is 1.46 A and a 5 A load peaks at 5.73 A, so the inductor has to be rated above 6 A saturation to keep the peak inside the transient allowance with margin for a load step.
Efficiency at that operating point is 95 percent, which puts 26.3 W into the converter and 1.32 W into the package, and the 18-lead QFN has to pass that through its thermal pad. The data sheet gives this body 40 C/W junction to ambient and 12 C/W junction to the pad, so 1.32 W is a 53 C rise on the JEDEC board, and the pad, the vias under it and the copper on the far side are part of the current rating rather than an afterthought. A two layer board with a small pad will not deliver 5 A at 42 V in and 85 C ambient no matter which grade is fitted.
Two questions buyers ask
Does the I grade cost more than the E grade? It is a separate order line and the price difference is real but small at volume, and the decision is usually made by the qualification document rather than by the cent. The larger cost is the schedule: the I code is not always on the shelf in every tape width, so a product that switches from E to I late in the programme can lose weeks. Decide the grade before the first prototype build.
Is the I grade automotive? No. Automotive parts in this family carry a W in the code and come from a controlled process with their own reliability reporting. The I letter is a temperature guarantee for industrial use, and a vehicle bill of materials needs the W code even if the temperature range looks the same.
Sourcing notes and next step
Send the exact code with the I letter and the TR suffix, plus the annual quantity and the ambient the board sees in the enclosure, and the quote is built on the grade that actually passes the test. Our BOM shortage page covers the route when one grade is short and the other is on the shelf, the second source page explains how an alternative is checked against the input current and the frequency floor, and the analog and mixed signal category lists the rest of the family.