LT8640HUDC#TRPBF
Product Specifications
LT8640HUDC#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8640HUDC#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8640HUDC#TRPBF: the 150 C member of the 5 A Silent Switcher family
The LT8640HUDC#TRPBF is the H grade of the 5 A, 42 V synchronous step-down regulator in the 18-lead 3 mm by 4 mm QFN. In the family order table the H suffix marks the higher junction temperature grade, which in this family is 150 C against the 125 C of the E and I grades. The electrical behaviour is the same part: 3.4 V to 42 V input, 5 A continuous and 7 A peak transient, 2.5 uA in burst mode, a 30 ns minimum on time and 100 mV of dropout at 1 A.
What the grade buys and what it does not
| Grade on this code | H, 150 C junction |
| E and I grades in the family | 125 C junction |
| Input range | 3.4 V to 42 V, unchanged by the grade |
| Output current | 5 A continuous, 7 A peak transient |
| Quiescent current | 2.5 uA in burst mode |
| Minimum on time | 30 ns |
| Dropout | 100 mV at 1 A |
| Package | 18-lead 3 mm by 4 mm QFN, MSL 3 |
| Automotive | a separate W code, not this one |
The grade is a limit, not a thermal solution
A 150 C rating says the part is characterised and guaranteed to that junction temperature; it does not say the package can hold the junction below 150 C in a hot enclosure. The 5 A conversion is where that distinction bites. At 95 percent efficiency a 5 V 5 A output is 26.3 W in and 1.32 W of loss in an 18-lead QFN, and at 93 percent into 3.3 V it is 1.24 W. The data sheet gives this body 40 C/W junction to ambient and 12 C/W junction to the pad, so 1.32 W is a 53 C rise on the JEDEC board. In an 85 C ambient the junction lands near 138 C, inside the H rating and well outside the E rating; in a 105 C ambient it is about 158 C, outside the H rating as well, which is where the pad copper and the switching frequency start to matter more than the grade letter.
The lifetime note in this family is worth stating plainly: operating life is derated above 125 C junction, so a part running at 145 C continuously does not carry the same expected life as the same part at 110 C. A product that needs the H grade to pass a temperature test and then runs near the top of the range has moved the reliability question into the qualification report rather than removed it. The usual response is to lower the switching frequency, which cuts switching loss, or to share the load between two phases.
Load dump and the 42 V ceiling
The grade does not raise the input rating. 42 V is the family maximum, a 24 V industrial bus at plus 20 percent is 28.8 V and fits, and a 48 V telecom bus at plus 10 percent is 52.8 V and does not. A vehicle supply is the case the 42 V number is really about: a centralised load dump clamp holds the bus at a level the part survives, and an unsuppressed load dump does not. The 65 V members of the family, the LT8620 and LT8641, are the ones for a 48 V bus and for an unclamped automotive input, and their lower current ratings are the trade.
Burst mode and the low current end
The 2.5 uA figure is the regulator supply current with the output in regulation and no load, in burst mode. Over a year it is 21.9 mAh, which is small against any battery a 5 A converter would sit in, but the number that matters in a standby product is the sum of the regulator, the feedback divider and the leakage of the output capacitor. A divider drawing 4 uA dominates the regulator and makes the grade choice irrelevant to standby life. Where the H grade does pay at the low current end is drift: the reference and the error amplifier are characterised over the wider range, so a product that starts at minus 40 C and runs hot does not need a separate qualification of the control loop.
Two questions buyers ask
Can the H grade replace the E grade on an existing board? Yes in the electrical sense: same die, same pinout, same external components and the same frequency resistor. The H part is specified over a wider junction range, so a board qualified with the E part will accept the H part. The reverse is not true, and substituting an E part into a build that was qualified at 150 C is a specification change even though the parts look identical on the reel.
Is this the automotive part? No. Automotive availability in this family comes from the W suffix on a controlled process flow, and the order table lists those codes separately. An H grade without the W is an industrial part specified to 150 C; it carries no automotive reliability report and no controlled process documentation. A tier one bill of materials will reject it at audit even though it is the wider temperature grade.
Sourcing notes and next step
Quote the grade letter explicitly, because the E, I and H codes are separate line items with separate lead times and one cannot be released against another. Send the annual quantity and the temperature the board actually sees, and the quote can be built around the grade that survives it. Our defense grade components page covers the documentation question for the other high reliability market, the drop in replacement page explains how a grade substitution is verified, and the analog and mixed signal category holds the rest of the 42 V range.
Request Quote — In Stock, 100% New & Original, Full Warranty