LT8616IFE#TRPBF
Product Specifications
LT8616IFE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8616IFE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8616IFE#TRPBF: two independent inputs with a full minus 40 C guarantee
The LT8616IFE#TRPBF is the I grade of the dual 42 V step-down regulator in the 28-lead TSSOP, guaranteed over the full minus 40 C to 125 C junction range. Channel one delivers 1.5 A and channel two 2.5 A, each from its own input pin, with 6.5 uA drawn with both channels enabled in burst mode and a 35 ns minimum on time. The combination of separate inputs and a full temperature guarantee is what makes it a fit for equipment that runs from two different buses and has to start cold.
What separate inputs buy
| Grade on this code | I, guaranteed minus 40 C to 125 C junction |
| Input range | 3.4 V to 42 V, one pin per channel |
| Output current | 1.5 A channel one, 2.5 A channel two |
| Quiescent current | 6.5 uA with both channels enabled |
| Minimum on time | 35 ns |
| Frequency | 200 kHz to 3 MHz, channels 180 degrees apart |
| Package | 28-lead TSSOP, 30 C/W junction to ambient |
| Pin fault behaviour | output stays at or below regulation on an adjacent pin short |
Two buses in one package
A product with a 24 V main bus and a 12 V backup or auxiliary rail can feed both channels of this part from their own sources and keep the two grounds and the two input capacitors separate. The channels then behave like two regulators that happen to share a die: a fault on one input does not pull the other down, and a short on one output does not disturb the other, which the data sheet states explicitly as a property of the channel architecture.
The 180 degree phase relationship only helps when both channels come from the same rail. With separate inputs the phases still alternate, which is harmless, but the input ripple cancellation does not apply because the two currents flow in different loops. The benefit in that arrangement is the package and the board area, not the ripple.
What the I grade adds on a cold start
The E grade in this family is guaranteed from 0 C to 125 C with the wider range assured by characterisation, and the I grade is guaranteed over the full minus 40 C to 125 C. A product that must show a cold start in its qualification report needs the I code. The specifications that move at the cold end are the reference, the 1 V enable threshold and the current limit, and the enable threshold is the one that sets the input undervoltage lockout: a divider built at 25 C has to be checked against the threshold window at minus 40 C before the board is released.
The other cold start question is the input capacitor. At minus 40 C a ceramic with a high dielectric constant loses capacitance and the ESR of an aluminium part rises, so the input loop that was quiet at 25 C can ring. A stable dielectric ceramic close to the pins plus a bulk part elsewhere is the usual answer, and the 4.7 uF the data sheet's typical application uses is a starting point rather than a rule.
Two questions buyers ask
Can one channel be left unused? Yes, with the rule the data sheet gives: VIN2 is not connected to the shared internal supply, so channel two can have its input floating without drawing current, but channel two needs VIN1 present for its own internal circuitry. A single channel application should tie VIN2 to VIN1 or leave it open as the note describes, and ground the unused enable pin rather than leaving it floating.
Is the TSSOP the right body for a cold climate product? The body does not change the temperature guarantee, which comes from the grade. The TSSOP is chosen for its 30 C/W junction to ambient and for the pin fault behaviour, both of which matter more in a product that runs hot or that has to fail safe. A cold climate product with modest dissipation can use either body.
Sourcing notes and next step
Give the exact code with the I letter and the FE package letters, the two bus voltages and the annual quantity, and the quote is built on the grade and the body the product needs. Our component cost page compares a dual part with two single regulators, the power management cross reference page shows how a channel is matched when one rail is short, and the analog and mixed signal category lists the rest of the family.
LT8616IFE#TRPBF at 2 MHz: the 35 ns floor that decides whether 42 V to 3.3 V is allowed at all
The part switches from 200 kHz to 3 MHz, has a 35 ns minimum on time and takes 3.4 V to 42 V on each of its two inputs. Those three figures interact, and the interaction is what a buyer with a 48 V backplane or a 42 V automotive rail actually needs to check. At 42 V in and 3.3 V out the duty cycle is 7.86 percent, so the on time at 3 MHz would have to be 26.2 ns, which is below the 35 ns floor: the loop cannot regulate at that frequency and will either skip pulses or let the output rise. The highest frequency that holds 7.86 percent with a 35 ns on time is 2.245 MHz, so 2 MHz is the practical ceiling for that ratio and 2.2 MHz is right at the edge.
The same arithmetic at a 5 V output
Changing the output to 5 V raises the duty to 11.9 percent, and at 3 MHz that is 39.7 ns, which clears the floor. So the same converter can run at its full 3 MHz with a 5 V output and cannot with a 3.3 V output from the same 42 V rail. This is the reason a dual channel part looks like it has more headroom than it does: the two channels share a package and a thermal path but not a duty cycle, and one of them can be at 2 MHz while the other sits at 1 MHz for the same reason.
Two and a half amps on the second channel, at 42 V in
The second channel carries 2.5 A at 3.3 V, which is 8.25 W. At 88 percent efficiency that is 9.38 W of input, or 223 mA from 42 V. The first channel at 1.5 A and 3.3 V adds 4.95 W, so the pair delivers 13.2 W and draws about 357 mA from the bus. A 42 V bus at 357 mA is a modest cable current, and the part's rating is about the 42 V transient and the switch voltage rather than about power delivery: the same package can move far more current from a 12 V rail than from 42 V before the thermal limit is reached.
What the 180 degree phase buys and what it does not
The two channels run 180 degrees apart, which halves the ripple current the input capacitor sees when both are at the same frequency and duty. It does not help when the frequencies differ, which is exactly what the duty floor forces at 42 V to 3.3 V on one channel and 5 V on the other. A board that needs the input ripple cancellation should set both channels to the same, lower frequency and accept the larger inductor, rather than run one channel fast and lose the cancellation the phase relationship was meant to provide.
| Frequency | On time at 42 V to 3.3 V | Against the 35 ns floor | On time at 42 V to 5 V | Against the 35 ns floor |
|---|---|---|---|---|
| 1.0 MHz | 78.6 ns | passes | 119.0 ns | passes |
| 2.0 MHz | 39.3 ns | passes by 4.3 ns | 59.5 ns | passes |
| 2.2 MHz | 35.7 ns | at the edge | 54.1 ns | passes |
| 3.0 MHz | 26.2 ns | fails by 8.8 ns | 39.7 ns | passes |
Step down part equivalents are on power management cross reference, the substitution checks are on how to verify a drop in replacement, and consolidated ordering for a rail set is on one stop BOM sourcing.
Request Quote — In Stock, 100% New & Original, Full Warranty