LT8610AHMSE-5#TRPBF
Product Specifications
LT8610AHMSE-5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8610AHMSE-5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT8610AHMSE-5#TRPBF: fixed 5 V at a 150 C junction
LT8610AHMSE-5#TRPBF combines the fixed 5 V output of the LT8610A with the H grade junction limit of 150 C. It is the code for a hot enclosure that wants 3.5 A at 5 V and does not want a divider: the output is trimmed to 4.94 V to 5.06 V inside the part and the junction is guaranteed over -40 C to 150 C.
Published values
| Parameter | Value |
|---|---|
| Junction grade | H, guaranteed over -40 C to 150 C |
| Output | 5 V fixed, 4.94 V to 5.06 V |
| Input voltage | 3.4 V to 42 V |
| Continuous output | 3.5 A |
| Minimum on time | 30 ns |
| Top switch current limit | 5 A minimum |
| Efficiency | 95 percent at 1 A, 5 V out from 12 V |
| Loss at full load | 0.92 W, 37 C of rise on 40 C/W |
| Power good | plus or minus 9 percent, 450 mV at 5 V |
| Quiescent current | 2.5 uA |
| Thermal resistance | 40 C/W |
| Package | 16-lead MSOP, VOUT on pin 16 |
| Release | industrial, no W suffix |
The ambient ceiling at full load
17.5 W out at 95 percent is 0.92 W of loss, which is 37 C of rise. A 150 C junction therefore allows a 113 C ambient at 3.5 A, against 88 C for the 125 C grade. The extra 25 C is the whole value of the H suffix in a sealed box.
That figure assumes the 40 C/W of a JEDEC board. A two layer board with the pad on a small copper island can be well above 60 C/W, which takes the same load to a 68 C ambient ceiling. The thermal resistance of the actual board is the number to measure, not the one in the table.
Fixed 5 V in an enclosure that cannot be trimmed
A sealed instrument is hard to rework, so the divider is a liability: two resistors that can drift, a node that can pick up switching noise, and a tolerance stack that has to be signed off. The fixed part deletes all three, and the published 1.2 percent window includes everything inside the package.
The trade is flexibility. A 5 V rail that later needs to become 5.2 V needs a new order code and a new reel, not two resistors. Products that go through several output revisions usually stay on the adjustable part for that reason.
The 30 ns floor and a 12 V input
12 V to 5 V is 41.7 percent duty, nowhere near the minimum on time, so the floor does not bind and the full 2.2 MHz is available. The floor matters only when the input is far above the output.
At 42 V to 5 V the duty is 11.9 percent and the on time at 2.2 MHz is 54.1 ns, which clears 30 ns comfortably. This part is therefore usable across the whole input range at the top of the frequency band, which is what a hot enclosure usually wants: small magnetics and the loss spread over a higher frequency.
Sourcing notes for this family: defense grade components holds the cross references, the power management cross reference is the pre substitution check, and OEM procurement is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask
Does the H grade raise the current rating? No. It raises the junction limit, which raises the ambient the same current can be delivered into. The 3.5 A rating and the 5 A switch limit do not change.
Can this replace the adjustable H part? Only with a board change: pin 16 is VOUT here and FB on the adjustable version. The electrical result is the same 5 V rail with one less divider.