LT8609SIV#PBF
Product Specifications
LT8609SIV#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8609SIV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT8609SIV#PBF: the I grade of the 2 A Silent Switcher buck
LT8609SIV#PBF is the industrial release of the LT8609S, a 42 V synchronous buck that carries 2 A continuously and 3 A for less than one second, in a 16-lead 3 mm by 3 mm laminate LQFN. It is not an LT8609A with a different label: the feedback reference is 0.774 V against 0.782 V, the continuous rating is 2 A against 3 A, and the package holds its own bypass capacitors so the radiated behaviour does not depend on where the input capacitor sits.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 3.0 V to 42 V |
| Continuous output | 2 A |
| Peak output | 3 A for less than one second |
| Feedback reference | 0.774 V typical |
| Reference at 25 C | 0.770 V to 0.778 V, an 8 mV window |
| Reference over -40 to 125 C | 0.758 V to 0.794 V, a 36 mV window |
| Top switch on resistance | 185 mOhm |
| Bottom switch on resistance | 115 mOhm |
| Top switch current limit | 3.4 A minimum, 4.75 A typical, 5.7 A maximum |
| Minimum on time | 45 ns |
| Switching frequency | 200 kHz to 2.2 MHz, set by RT or an external clock |
| Quiescent current | 1.7 uA not switching, 1 uA in shutdown |
| Power good window | plus or minus 8.5 percent of the set output |
| Package and thermal | 16-lead 3 mm by 3 mm LQFN, 50 C/W on a JEDEC board, 31 C/W on the demo board |
| Release | I grade, guaranteed over -40 to 125 C, MSL 3, gold pad finish |
Three amperes is a peak, and the switch agrees
The 3 A figure is attached to a duration, less than one second, and the protection behind it is the top switch current limit at 3.4 A minimum, 4.75 A typical and 5.7 A maximum. A load that reaches 3 A therefore runs 0.4 A under the minimum limit, which is the margin that decides whether a saturated inductor trips the switch or simply draws more current than the loop wants.
In a real product that peak belongs to a transmit slot or a motor start, not to a steady rail. An inductor chosen for 2 A of average current with a saturation point above 4 A leaves the current limit as the protection rather than the magnetics, and the Burst Mode loop keeps the output ripple below 10 mV peak to peak while the load is light.
The 45 ns floor at the top of the input range
42 V to 3.3 V is a 7.86 percent duty cycle, which at 2.2 MHz asks for 35.7 ns of on time against a 45 ns minimum. The floor caps that ratio at 1.746 MHz. Read the other way round, at 2.2 MHz the floor is 9.9 percent of the period, so a rail between 40 V and 42 V cannot hold 2.2 MHz into 3.3 V.
42 V to 5 V is 11.9 percent, which is 54 ns at 2.2 MHz, and that clears the floor with about 9 ns to spare. A 5 V rail can use the whole band. A 3.3 V rail from a 24 V or 36 V industrial supply should plan on 1.75 MHz or below, and the inductor and the output capacitor follow from that number rather than from the headline frequency.
The reference window is wider than the LT8609A
At 25 C the reference is specified 0.770 V to 0.778 V, an 8 mV window. Over the full -40 to 125 C range the window opens to 0.758 V to 0.794 V, which is 36 mV and plus or minus 2.3 percent around 0.774 V. On a 3.3 V output that is 153 mV of spread and on 5 V it is 233 mV.
The LT8609 and the LT8609A publish 0.782 V with a 24 mV window over temperature. Moving a board from one family to the other changes the output by 1.02 percent, which is 34 mV at 3.3 V and 51 mV at 5 V, before any divider tolerance is counted. That is the figure a rail budget has to carry when a customer substitutes one order code for the other.
Two thermal numbers for one package
The laminate LQFN publishes 50 C/W on a JEDEC board and 31 C/W on the demo board. At 2 A into 3.3 V from 12 V the conduction loss in the two switches is 0.482 W, which is 24 C of rise on the JEDEC figure and 15 C on the demo board before switching loss is added.
The body is a laminate package with a QFN footprint, MSL 3 and a gold pad finish. It does not share a land pattern with the MSOP or the 10-lead DFN of the LT8609A, and the exposed pad is the only thermal path, so the copper under the part is part of the current rating at any ambient above 60 C.
For a board that has to keep running while a reel runs out, the power management cross reference is where the family alternatives sit, the ADI second source page is the check list before a substitute goes in, and how to verify a drop in replacement is how a gap is covered without a new line item.
Two questions buyers ask
Can the LT8609S replace an LT8609A on the same board? Only after the divider is checked. 0.774 V against 0.782 V puts the output 1.02 percent low, 34 mV at 3.3 V, and the continuous rating falls from 3 A to 2 A, so the same copper carries more loss at the same load.
What separates the I grade from the E grade? The I grade is guaranteed over -40 to 125 C junction. The E grade is guaranteed from 0 to 125 C and the cold end is assured by characterisation, so a product with a cold start specification belongs on the I grade.