LT8609AHDDM#WTRPBF
Product Specifications
LT8609AHDDM#WTRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8609AHDDM#WTRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT8609AHDDM#WTRPBF: the 150 C DFN code, and where it is really needed
LT8609AHDDM#WTRPBF is the H grade of the 3 A synchronous buck in the LT8609 family, in the 3 mm by 3 mm DFN, automotive release, on tape and reel. The H moves the guaranteed junction range to 150 C. That is 25 C more than the E and I grades, and it is the difference between a converter that survives a hot enclosure and one that folds back. The rest of the table is the family table.
Published values
| Parameter | Value |
|---|---|
| Temperature grade | H, guaranteed minus 40 C to 150 C junction |
| Package | 10 lead 3 mm by 3 mm DFN, theta JA 45 C/W, theta JC 10 C/W |
| Input voltage | 3.0 V to 42 V |
| Continuous output | 3 A |
| Feedback reference | 0.782 V, 0.770 V to 0.794 V over the full range |
| Minimum on time | 45 ns typical, 75 ns maximum |
| Top switch on resistance | 185 mOhm at 1 A |
| Top switch current limit | 3.4 A minimum, 5.7 A maximum |
| Qualification | AEC-Q100, W release for automotive use |
| Lifetime note | operating life derates above 125 C junction |
150 C is a rating, not a target
The vendor's own note says operating lifetime is derated above 125 C junction, so the H grade buys the right to run there, not a free pass to run there continuously. A converter that sits at 140 C for a decade is a different product from one that touches 140 C during a soak test.
The useful way to read the grade is as headroom for excursions: a 105 C ambient with a 45 C/W body and 1 W of loss lands at 150 C, which the H grade survives and the E grade does not. That is the case the grade exists for.
Working out the junction without a simulator
Losses are conduction plus switching plus housekeeping. From 12 V to 5 V at 3 A, the top switch at 185 mOhm and 41.7 percent duty is 694 mW, the bottom switch at 115 mOhm over the remaining 58.3 percent is 604 mW, and the total lands within 10 percent of the 1.13 W that 93 percent efficiency implies.
At 45 C/W that is a 51 C rise. In a 105 C enclosure the junction sits at 156 C, so the H grade is still short: the load has to come down to about 2.5 A or the board needs copper and airflow. The grade raises the ceiling; it does not remove the arithmetic.
Why the DFN body is the one chosen for this job
The DFN is 3 mm by 3 mm against the MSOP's larger outline, so it fits a denser board, and its exposed pad sits directly under the switches. The cost is 5 C/W: 45 against the MSOP's 40. On a 150 C part that 5 C/W is worth 5 C at 1 W of loss, which is the margin between a 2.5 A and a 3 A load on a hot day.
Side wettable flanks on this body also let an optical inspection see the joint, which is why the automotive release uses it.
Buyers usually arrive at defense grade components to find the family alternatives, then use component obsolescence management to confirm a substitute before it is fitted; the power management cross reference is the routine for a part that has already stopped shipping.
Two questions buyers ask
What is different between H and J grades? Both are 150 C. The J grade has a wider reference tolerance, 0.766 V to 0.798 V instead of 0.770 V to 0.794 V, which is a looser output window for the same money saved on test.
Does the H grade run cooler? No. Same die, same resistance, same loss. It is tested over a wider range and guaranteed there; the heat still has to leave through the pad.