LT3798MPMSE#TRPBF
Product Specifications
LT3798MPMSE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3798MPMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3798MPMSE: Minus 55 C Start-Up on an Offline Flyback Controller
The MP suffix on the LT3798 is the widest grade in the family: minus 55 C to 150 C junction, against minus 40 C to 125 C for the E and I codes and minus 40 C to 150 C for the H. The silicon and the pinout are the same 16-lead MSOP part that runs a 24 W isolated bus converter without an opto-coupler. What an MP build has to prove is not the controller, which is specified, but the parts around it: the electrolytic capacitor, the transformer and the start-up circuit are the components that usually fail the minus 55 C requirement.
Published values
| Parameter | Value |
|---|---|
| Junction temperature range | MP minus 55 C to 150 C, H minus 40 C to 150 C, E and I minus 40 C to 125 C |
| Input voltage range | 10 V to 38 V operating, 42 V absolute maximum |
| Enable threshold | 1.21 to 1.29 V rising, 8 to 12 uA hysteresis current |
| VIN shunt regulator | 40 V, 8 mA current limit |
| Sense current limit threshold | 96 to 107 mV |
| Feedback regulation voltage | 1.22 to 1.28 V |
| Internal rail | 10 V typical, 9.8 to 10.4 V |
| Oscillator range | 4 kHz to 150 kHz, 20 kHz backup |
| Maximum off time | 190 us at the bottom of the frequency range |
| Thermal resistance | 50 C/W junction to ambient |
| No load consumption | Under 0.5 W |
| Package | 16-lead plastic MSOP with exposed pad, MSE |
What the minus 55 C grade actually guarantees
The order table gives the MP code the widest window and the electrical characteristics apply over it, so the controller's thresholds, oscillator and reference are all specified at minus 55 C. The parts that are not covered by that guarantee are the ones an engineer tends to forget: an aluminium electrolytic loses most of its capacitance and gains a large ESR at minus 55 C, so the 560 uF on the output becomes a much smaller capacitor with a much higher impedance, and the loop that was stable at 25 C can ring. A polymer or a ceramic bank is the usual answer.
Start-up is the second question. The part has a shunt regulator on VIN and a 45 to 70 uA quiescent current, so the trickle path that charges the input capacitor before the converter runs has to work at the cold end. A resistor from the high voltage rail that was sized for 25 C will still work at minus 55 C because resistors do not care, but the time constant of the input capacitor and the start-up current will be longer, and the converter may need a longer soft-start window.
The transformer is the real cold temperature component
At minus 55 C the ferrite saturation flux density rises, which helps, while the copper resistivity falls to about 0.6 of its 25 C value, which also helps the winding loss. What does not help is the insulation system and the mechanical stress: a potted transformer built for minus 40 C can crack its bobbin at minus 55 C if the potting compound and the bobbin have different expansion coefficients. That is a qualification question for the magnetics supplier, not a question about the controller.
Because the part regulates from the primary waveform, the transformer's leakage inductance appears directly in the output voltage equation. A cold transformer with the same turns ratio but a different leakage shifts the output, so the transformer should be qualified at both temperature extremes, not just at room temperature.
Where the MP grade is worth its price
Equipment that is stored outdoors in a cold climate and switched on without a warm-up period is the obvious case, as is anything that specifies a minus 55 C storage and operating requirement for transport or defence use. Inside a heated enclosure the MP code buys nothing over the H, which already reaches 150 C junction, and the E and I codes are cheaper again.
The purchase order needs the MP in the code itself. The top marking is shared across the family, so a reel of MP parts and a reel of E parts look the same on the bench, and only the label and the paperwork distinguish them.
Sourcing notes for this family: the power management cross reference holds the cross references, defense grade components is the pre substitution check, and medical device components is what we use when the part on the drawing is not on the shelf.
Two questions buyers ask
Is the MP code a different circuit? No, it is the same controller with a wider tested range and the same external component values. What changes is the qualification of the parts around it and the documentation that comes with the order.
Can an MP part be used at 25 C? Yes, its range contains every other grade's range, so it works wherever the E, I or H works. It is simply screened over a wider window and priced accordingly.