Contact Us

LT3798HMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3798HMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3798HMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3798HMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3798HMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3798HMSE#TRPBF: isolated flyback without an opto, 150 C

LT3798HMSE#TRPBF is the H grade of an isolated flyback controller that regulates the output from the primary side, with no optocoupler and no third winding, in a 16 lead MSOP, on tape and reel. It takes 10 V to 38 V in, senses primary current at 102 mV, and holds power factor above 0.97 on a sinusoidal input. The H grade extends the guaranteed range to 150 C.

Published values

ParameterValue
Input voltage10 V to 38 V
Primary current sense102 mV, 96 mV to 107 mV
Feedback threshold1.250 V secondary referred through the transformer ratio
Voltage reference2.00 V
Power factorabove 0.97 at the nominal input
Internal gate drive supply10 V
Package and thermal16 lead MSOP, theta JA 50 C/W, theta JC 10 C/W
Temperature gradeH, guaranteed minus 40 C to 150 C
Grade ladderE and I to 125 C, H to 150 C, MP from minus 55 C
Isolationset by the transformer, not by the controller

Primary side sensing means no opto to drift

The part samples the reflected output voltage during the off time, so the feedback path is the transformer itself. An optocoupler with a 50 percent current transfer ratio drift over temperature and age is replaced by a ratio that is fixed by the winding and the resistor divider.

The price is that the output is only as accurate as the transformer's coupling and leakage, which is why the data sheet specifies the transformer and the timing rather than offering a universal formula.

One hundred and two millivolts of primary sense

At 1 A primary current the sense resistor is 0.102 Ohm and dissipates 102 mW; at 500 mA it is 0.204 Ohm and 51 mW. The resistor is in the primary, so it also carries the magnetising current, and that is what the part uses as its current signal.

The choice of resistor is therefore the peak current limit as well as the power measurement, and a board that changes the transformer usually has to change the resistor with it.

Where the 150 C grade earns its place

The MSOP is 50 C/W, which is the highest in this family and twice the TSSOP controllers. At 1 W of loss that is a 50 C rise, so a 100 C ambient lands at 150 C: the H grade is the one that survives a sealed adapter, and the MP grade extends the cold end to minus 55 C.

On a 24 W adapter at 86 percent efficiency the loss is 3.36 W, so the controller is a small part of a larger thermal problem that the transformer and the snubber dominate.

Where a customer needs a second position on this part, the power management cross reference is the starting point, medical device components sets out the checks a substitution has to pass, and defense grade components is the short lead time route we quote against.

Two questions buyers ask

Does the part provide isolation? No. The barrier is the transformer; the controller only avoids the optocoupler that would otherwise cross it. The isolation rating comes from the transformer and the spacing.

What sets the output voltage? The transformer ratio, the primary sense resistor and the divider on the feedback pin, together with the 1.250 V threshold. The data sheet's worked example ties them, so a transformer change is a full recalculation.