Contact Us

LT3763HFE#TRPBF

Brand: Analog Devices
Analog Devices LT3763HFE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3763HFE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3763HFE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3763HFE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3763HFE#TRPBF: 60 V at 20 A in the 150 C grade

LT3763HFE#TRPBF is the H grade of a 60 V, 20 A step-down controller built for constant current loads, in a 28 lead TSSOP with exposed pad, on tape and reel. It senses output current at 50 mV full scale and has a separate input current limit, which is what makes it usable on a supply that cannot deliver the load's peak. The H grade extends the guaranteed junction range to 150 C.

Published values

ParameterValue
Input voltageup to 60 V
Output current20 A with external switches and sense resistor
Current sense full scale50 mV, 46 mV to 54 mV over temperature
Input current limit sense10 mV, 6 mV to 14 mV over temperature
Voltage reference2.00 V
Feedback threshold1.206 V, 1.188 V to 1.224 V
Switching frequency200 kHz to 1 MHz, resistor set and synchronisable
Quiescent current1.7 mA not switching, 3.5 mA maximum
Package and thermal28 lead TSSOP, theta JA 30 C/W, theta JC 10 C/W
Temperature gradeH, guaranteed minus 40 C to 150 C

Fifty millivolts is the sense resistor choice

A 50 mV full scale at 20 A is a 2.5 mOhm sense resistor, which dissipates 1 W at full load. At 10 A the same threshold allows 5 mOhm and 0.5 W, so a build that only needs 10 A can halve the sense loss by doubling the resistor and accepting half the full scale current.

That is the cheapest efficiency gain on the board and it is usually missed. One watt out of a 40 W load is 2.5 percent, and it is dissipated in a resistor rather than in the switches.

The input current limit is the feature that sells it

The second sense amplifier works at 10 mV, so a 5 mOhm shunt sets a 2 A input limit and a 2 mOhm shunt sets 5 A. On a 12 V input feeding a 20 A load at low voltage, the input current is what the connector and the upstream supply have to survive, and most controllers leave that to a fuse.

A controller that folds the output current back when the input current reaches a limit turns a brown out into a dimming event. That is the difference between a product that restarts and one that keeps working.

Duty cycle and the 60 V ceiling

From 60 V to 12 V the duty cycle is 20 percent and from 60 V to 48 V it is 80 percent. At 300 kHz those are on times of 667 ns and 2.67 microseconds, both far from any minimum, so the whole input range is usable at any frequency in the band.

The H grade matters because the controller sits next to the switches: at 60 V and 3.5 mA the part itself dissipates 210 mW, a 6 C rise, and the real heat is in the external FETs and the sense resistor.

For a board that has to keep running while a reel runs out, defense grade components is where the family alternatives sit, the power management cross reference is the check list before a substitute goes in, and medical device components is how a gap is covered without a new line item.

Two questions buyers ask

Does the part include the switches? No. It is a controller: the FETs, inductor and sense resistor are external, which is how 20 A is reached in a 28 lead body.

What sets the 20 A rating? The external components. The controller drives the gate; the current path is the FETs, the inductor and the 2.5 mOhm sense resistor, and those decide what the board can hold thermally.

LT3763HFE#TRPBF: The 150C Code of the 60 V LED Controller, and Where the Heat Really Sits

The LT3763HFE#TRPBF is the 150 C grade of the same 60 V current mode controller in the 28-lead TSSOP. The ordering table publishes the E and I codes at minus 40 to plus 125 C and this H code at minus 40 to plus 150 C, with the same die and the same pinout. On a lighting product the case for the H grade is usually a sealed housing or a fixture that sits next to the LED array, where the board ambient is well above the room temperature the prototype was tested at.

The controller is cool, the power stage is not

The controller's own dissipation is small: 1.7 mA typical at the input, 5 V internal regulator at 10 mA of load, and gate drive through 2.2 ohm pull up and 1.3 ohm pull down. The heat belongs to the external MOSFETs, the inductor and the sense resistor. At 20 A into a 30 V string the load is 600 W, the sense resistor at 2.5 milliohm dissipates 1 W, and the switching losses in two FETs are several watts, all of which have to leave through copper that the controller package never touches. Buying the H grade for thermal margin on the controller alone does not solve a fixture that is overheating in the power stage.

Dimming ratio against minimum on time

The part is quoted at 3000 to 1 of PWM dimming, and the limit on that ratio is the minimum on time of the gate drivers, 55 ns at the top gate and 50 ns at the bottom. A 100 Hz dimming frame is 10 ms, so a 3000 to 1 ratio is a 3.3 microsecond pulse, well above the driver floor. At 1 kHz the same ratio asks for 333 ns, still above the floor but close enough that rise and fall times start to matter, because a 333 ns pulse with 50 ns edges is mostly transition rather than flat current. The practical dimming floor is therefore set by the current loop settling, not by the driver specification.

ItemPublished valueWhat it decides on a board
Grade windowminus 40 to plus 150 CSealed fixture and high ambient locations
Overvoltage faultFB threshold just above the regulation pointOpen string protection
Fault detectionOpen, short and C/10 reportingDiagnostics reported to the host
Shutdown current0.2 uA typical, 2 uA maximumBattery drain in a parked fixture
Package28-lead TSSOP with exposed pad, 30 C per wattGround return and thermal vias

Fault reporting that a host can actually use

The controller separates an open string, a short and a C/10 threshold, and it has a dedicated driver output for the dimming FET and a fault output for the host. That matters in a fixture that is not serviceable, because the difference between a shorted string and a string that has reached the end of charge changes what the controller does next. The overvoltage guard sits on the FB divider, so a string that opens drives the output up until that threshold is reached and the loop stops raising it, which keeps the output capacitor and the FETs inside their ratings while the fault is reported.

What changes between the three grades

Only the guaranteed temperature moves. The E, I and H codes share the pinout, the 51 mV sense point, the 200 kHz to 1 MHz range and the 6 V to 60 V input window, so a board built and qualified with the I code can move to the H code without a circuit change. The reason to do it is the measured ambient at the controller, and the reason not to do it is that the power stage is what fails first. Our power management cross reference page lists the family comparisons, the lead time page covers allocation, and the strategic sourcing page covers multi year planning for a fixture platform.