Contact Us

LT3757MPMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3757MPMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3757MPMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3757MPMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3757MPMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3757MPMSE: A Minus 55 C Controller in a 10 Lead MSOP

The MP suffix is the military temperature grade: minus 55 C to 150 C junction, tested over that range rather than characterised into it. Everything else about the part is the LT3757 that runs a boost, SEPIC, flyback or inverting converter from 2.9 V to 40 V, drives a low side FET from a 7.2 V internal regulator and regulates 1.6 V on a positive output or minus 0.800 V on a negative one. This order code exists for equipment that is stored and started at minus 55 C, and the interesting engineering is not the part, it is everything around it at that temperature.

Published values

ParameterValue
Input range2.9 V to 40 V
Temperature gradeMP, minus 55 C to 150 C junction, tested
Feedback point1.6 V positive, minus 0.800 V negative, plus or minus 2 percent
SENSE current limit110 mV typical, 100 to 120 mV over temperature
Switching frequency50 kHz to 1 MHz, set by one resistor, synchronisable
Minimum on and off time220 ns each
Gate drive supply7.2 V regulator, 17.5 V overvoltage lockout, 350 mV dropout at 10 mA
Quiescent current2.2 mA maximum, 1 uA shutdown
Soft start10 uA pull up, programmable ramp
Package and thermal10 lead MSOP, 40 C/W junction to ambient
Thermal budget at 125 C ambient25 C of rise, 0.62 W
Storage rangeminus 65 C to 150 C

The part is not the weak link at minus 55 C, the passives are

Three things move at minus 55 C and none of them is inside the controller. An aluminium electrolytic loses capacitance and multiplies its ESR, so an input filter that damps the switching edge at 25 C can ring at cold; a ceramic with a high dielectric constant loses most of its capacitance and shifts its voltage coefficient, which changes the loop compensation; and the FET's threshold voltage rises, which is fine at 6.9 V of gate drive and not fine if the gate is driven from a 5 V rail. The MP grade guarantees the controller over the range so that the converter can be debugged on its passives, which is where the failures actually are.

The oscillator is the one internal item worth checking. The 50 kHz to 1 MHz range is set by a resistor, and the resistor's own tolerance plus the part's frequency tolerance stack at cold. On a converter that is running near the 220 ns minimum on time at its highest frequency, a 15 percent shift in frequency at minus 55 C can push a build that was inside the limit at 25 C past it.

0.62 W is the whole thermal allowance at 125 C ambient

The MSOP is 40 C/W and the MP grade stops at a 150 C junction, so a 125 C ambient leaves 25 C of rise, which is 0.62 W. That is not much for a controller driving a 60 nC FET: 24 mA of gate current at 400 kHz from the 7.2 V rail is 173 mW, and the 2.2 mA of quiescent current at 40 V is another 88 mW, which together is 261 mW before the regulator's own losses. The remaining 360 mW is the headroom that decides whether the build has margin. At 105 C ambient the same package holds 1.12 W and the same circuit is comfortable.

Note that the MP grade is MSOP only. The 3 by 3 DFN order codes stop at a 125 C junction and a storage range that ends at 125 C, so a military build that was laid out for the DFN has to be re-laid out, not re-ordered.

Cold start and the shutdown divider

The shutdown and undervoltage pin threshold is 1.223 V typical, and at a 2.9 V input the pin sits at 1.33 V because the pin current is no longer negligible. A divider trimmed at room temperature to trip at 2.7 V can therefore fail to enable at minus 55 C when the input is at its minimum, and the symptom is a converter that works on the bench and does not start in the chamber. The fix is to set the trip point with margin, at 2.4 V rather than 2.7 V, and to check the divider current against the pin's 2 uA hysteresis current, which is what actually sets the release point.

Where a customer needs a second position on this part, defense grade components is the starting point, the power management cross reference sets out the checks a substitution has to pass, and the obsolete part cross reference hub is the short lead time route we quote against.

Two questions buyers ask

Is the MP grade the same silicon as the H grade? Same die, tested and guaranteed over a wider range: minus 55 C to 150 C against minus 40 C to 150 C. For a build that only needs minus 40 C the H part is the cheaper correct answer, and for minus 55 C storage the MP part is the only listing in this family.

Can the converter be started at minus 55 C with a 2.9 V input? The controller is guaranteed there. The input source is the question: at that temperature a battery's internal resistance is several times its room temperature value, so a 2.9 V rail that holds on the bench can collapse during the first switching cycles. Soft start on the SS pin, at 10 uA into the external capacitor, is the tool that keeps the inrush inside what the source can supply.