LT3748IMS#TRPBF
Product Specifications
LT3748IMS#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3748IMS#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3748IMS: An Isolated Flyback With No Opto and No Third Winding
The LT3748 regulates an isolated flyback output by watching the primary side flyback waveform, so a circuit needs no opto isolator, no third winding and no secondary side reference. Input range is 5 V to 100 V, the gate driver sources and sinks 1.9 A, and the converter runs in boundary mode so the transformer is small and the load regulation comes from the primary waveform rather than from a feedback path. This order code is the I grade in the high voltage 16 lead MSOP, guaranteed from minus 40 C to 125 C junction.
Published values
| Parameter | Value |
|---|---|
| Input range | 5 V to 100 V |
| Gate drive | 1.9 A average source and sink, 16 ns rise and fall into 3300 pF |
| Reference at RREF | 1.223 V typical, 1.195 to 1.245 V |
| Output setting | two resistors from RREF to RFB |
| Maximum sense threshold | 100 mV at VC equal 2.2 V, 90 to 110 mV |
| Minimum sense threshold | 15 mV at VC equal 0 V |
| SENSE overcurrent threshold | 130 mV typical |
| Minimum gate off time | 700 ns |
| Minimum gate on time | 250 ns |
| Internal gate supply | 7 V regulator, 3.6 V undervoltage lockout |
| Quiescent current | 1.3 mA typical, 1.75 mA maximum |
| Package and thermal | 16 lead MSOP, 90 C/W, 150 C maximum junction |
| Grade | I, guaranteed minus 40 C to 125 C junction |
Two resistors set the output, and the turns ratio is part of the formula
The output is set by the ratio of RFB to RREF multiplied by the reference and divided by the primary to secondary turns ratio. In the telecom circuit on the front page, 243 k over 6.04 k is a ratio of 40.2, and with a 4 to 1 transformer and a 1.223 V reference the ideal output is 12.3 V; the diode drop accounts for the difference between that and the 12 V printed on the drawing. Changing the transformer to a 2 to 1 part doubles the output for the same resistors, which is the trap: the resistors are the fine adjustment and the transformer is the coarse one.
The reference is 1.195 to 1.245 V across parts, which is 4 percent, and the TC pin adds a temperature dependent current into the RREF node, 27.5 uA with a 20 k resistor on the TC pin. That current is what compensates the diode's forward voltage change with temperature, and leaving the pin open on a circuit that expects it moves the output over temperature by more than the reference tolerance.
Boundary mode and the 700 ns minimum off time
In boundary mode the next cycle starts when the secondary current reaches zero, so the switching frequency is a function of load current, magnetising inductance and the input to output voltage ratio, not a value set by a resistor. The 700 ns minimum off time is what puts a ceiling on the frequency at light load: with a 3 us on time the converter would switch at 270 kHz, and at heavy load the off time shortens toward that floor while the on time lengthens. A transformer specified for 200 kHz at full load will see 300 kHz or more at half load, which changes the core loss and the EMI spectrum.
The 250 ns minimum on time is the other end. It limits how short an on pulse the controller can produce, which sets the minimum load before the converter starts skipping cycles and the output ripple grows. A 25 W converter that has to hold regulation at 1 percent load needs a bleed resistor or a transformer with enough magnetising inductance that the boundary frequency stays low.
What the 1.9 A gate drive is actually for
A 1.9 A driver into 3300 pF gives a 16 ns edge, which is a 1.5 A peak current from a 7 V rail. That is enough gate drive to switch a 100 V FET at 200 kHz with a 30 nC gate charge without spending the switching loss in the driver, and it is what allows the converter to run at 100 V input without a slow edge that would turn the FET into a resistor. The published figure is an average source and sink current, not a peak, so the gate charge per cycle at the chosen frequency has to be checked against it: 30 nC at 200 kHz is 6 mA average, which is trivial, and a 300 nC FET at the same frequency is 60 mA, which is where the driver starts to matter.
Where a customer needs a second position on this part, the power management cross reference is the starting point, component obsolescence management sets out the checks a substitution has to pass, and BOM shortage recovery is the short lead time route we quote against.
Two questions buyers ask
Does the output stay accurate without any secondary side feedback? It stays within the tolerance of the primary side sensing, which depends on the transformer's leakage inductance and the diode's forward drop. Load regulation is quoted from the primary waveform and it is not as tight as a secondary side reference, so a circuit that needs 1 percent over the full load range should check the curve in the datasheet rather than assume it.
Can the input go to 100 V and still drive a standard FET? Yes. The controller drives a low side FET from the 7 V internal rail, so the gate never sees the input voltage, and the drain has to be rated for the input plus the reflected output. A 48 V input with a 4 to 1 transformer and a 12 V output puts about 96 V across the FET, so a 150 V part is the practical choice, not a 100 V one.