Contact Us

LT3090IMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3090IMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3090IMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3090IMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3090IMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3090IMSE#TRPBF: 600 mA negative rail with 34 C/W of thermal headroom

The LT3090IMSE#TRPBF is the industrial grade of the 600 mA negative regulator in the 12-lead MSOP, taped and reeled for automatic placement. It is specified -40 C to 125 C at the junction and shares the whole electrical table with the rest of the family: -1.5 V to -36 V input, 0 V to -32 V output set by a single resistor, 50 uA SET current, 300 mV typical dropout at full load, 18 uV RMS noise and 85 dB of rejection at 120 Hz. What separates this code from the H and MP versions is only the temperature window, not the silicon or the pinout.

Published values

ParameterValue
Input voltage-1.5 V to -36 V
Output voltage0 V to -32 V
Output current600 mA
Dropout voltage185 mV at 1 mA, 270 mV at 100 mA, 300 mV at 600 mA
SET pin current50 uA, 1 percent initial
GND pin current1 mA at no load, 11.5 mA at 600 mA
Output noise18 uV RMS, 10 Hz to 100 kHz
Ripple rejection85 dB at 120 Hz, 50 dB at 10 kHz
Load regulation1.2 mV typical, 2.5 mV maximum
Thermal resistance34 C/W junction to ambient, 5.5 C/W to case
Package and grade12-lead MSOP, -40 C to 125 C, tape and reel

The arithmetic that decides the copper area

A negative rail usually comes from a charge pump or an inverting switcher, and the linear stage after it is asked to drop whatever the upstream converter leaves. A -6 V input feeding -3.3 V at the full 600 mA dissipates 1.62 W in the pass element plus about 69 mW in the quiescent path. At 34 C/W that is 57 C of rise, which puts a 125 C part at its limit with a 68 C ambient. The same rail at 300 mA is 0.85 W and 29 C of rise, which is comfortable. Between those two points the answer is not a bigger package but either a lower upstream voltage or two devices sharing the load, and the second option is why the output can be tied in parallel without ballast resistors.

Negative rails and the ground reference

On a positive regulator the reference sits above ground and the SET resistor divider is referenced to the same ground as the load. On this part the reference is 50 uA flowing out of the SET pin into a resistor that returns to ground, while the output is below ground, so the error amplifier works rail to rail and the output can be brought all the way to 0 V. The consequence on a test bench is that the SET pin must never be pulled below the negative rail, and the SET capacitor and resistor should be placed with their ground end on the same quiet node that the load uses. In a mixed-signal cabinet this is usually the analog ground, not the chassis.

Why the noise figure holds at any output

The output noise of 18 uV RMS over 10 Hz to 100 kHz and the rejection figures are quoted with a 4.7 uF output capacitor and a 0.1 uF capacitor on SET. Because the error amplifier runs at unity gain regardless of the SET resistor, the loop gain and therefore the noise and rejection behaviour do not change when the rail moves from -1.2 V to -15 V. That is unusual: on a conventional adjustable regulator the divider ratio moves the loop gain and the noise performance drifts with the setpoint. For a buyer specifying several negative rails in one instrument, it means one noise specification covers the whole family and the qualification work does not have to be repeated per rail.

Order code and stock

IMS is the industrial 12-lead MSOP in tape and reel; the E grade of the same body covers the same -40 C to 125 C window, and the H and MP grades extend the junction to 150 C. Because the die is identical, a change of grade is usually a paperwork change rather than a re-qualification, which is the cheapest way out of a shortage on this line. The BOM shortage recovery page covers that substitution path, the component cost page covers volume pricing across the negative families, and ADI part second source lists the codes that can move between grades without a board change.