Contact Us

LT3065HMSE#TRPBF

Brand: Analog Devices
Analog Devices LT3065HMSE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LT3065HMSE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LT3065HMSE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LT3065HMSE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LT3065HMSE#TRPBF: the 150 C tested grade in the 12-lead MSOP

The LT3065HMSE#TRPBF is the H grade of the LT3065, a 500 mA low dropout regulator with a 1.6 V to 45 V input range and an adjustable 0.6 V to 40 V output. It is supplied in the 12-lead MSOP on tape and reel and specified from minus 40 C to 150 C at the junction, with the high end tested rather than extrapolated. The H grade sits between the I and MP codes: it shares the I grade's cold limit and adds 25 C at the hot end, which is the 25 C that a 125 C part cannot give in a sealed enclosure on a hot day.

Published values

ParameterValue
Input voltage1.6 V to 45 V, 2.2 V maximum at 500 mA
Output voltage0.6 V to 40 V adjustable
Output current500 mA
Dropout voltage300 mV typical at 500 mA, 350 mV maximum
GND pin current55 uA no load, 11 mA at 500 mA
Output noise90 uV RMS bare, 25 uV RMS with 10 nF on REF/BYP
Current limit520 mA minimum internal, external set to plus or minus 10 percent
PWRGD trip point86 to 94 percent of nominal, 1.6 percent hysteresis
Shutdown current0.2 uA typical, 1 uA maximum
Thermal resistance28 C/W junction to ambient, 6 C/W to case
Grade and package12-lead MSOP, minus 40 C to 150 C, tape and reel

How 150 C is earned

The four grades of this family are defined by how they are tested, and the vendor is explicit about the difference. The E grade is tested at 25 C and guaranteed from 0 C to 125 C. The I grade is guaranteed over minus 40 C to 125 C. The H grade is tested at 150 C at the junction. The MP grade is tested over the full minus 55 C to 150 C range. So the H code buys a hot end that has been measured, not characterised, and it buys it without the minus 55 C cold end of the MP code. For a board that sits in a cabinet at 85 C ambient with 1.2 W in the regulator, the junction lands near 119 C and both the I and H parts are inside their window; the H part matters when the ambient itself climbs past 95 C or when the thermal path is worse than the model.

The derating line above 125 C

The 150 C rating is a survival limit, not a comfortable operating point. The vendor states that operating lifetime is derated at junction temperatures above 125 C, which means the last 25 C of the window is for overload, blocked airflow and fault conditions rather than for steady state. Anyone choosing between the I and H codes should compute the worst case junction first and then decide whether the number exceeds 125 C. If it does, the H grade lets the product ship, but the same calculation run over a ten year life points at a lower dissipation, a larger copper area or a switching pre regulator rather than at the wider grade. Buying the H part and running it at 145 C is the expensive way to fail a reliability review.

Noise, current limit and the pinout in one pass

The functional pins are the same on every grade. A capacitor on REF/BYP takes the noise from 90 uV RMS to 25 uV RMS at a 0.6 V output and also sets the soft start ramp, so a rail that must not load a weak source gets a larger capacitor here rather than an extra series device. The ADJ pin draws 16 nA out of the pin, which is why the divider's lower resistor is capped at 62 kOhm. The IMAX pin takes a resistor, 1.5 kOhm for about 200 mA or 604 Ohm for about 495 mA, and the limit holds to plus or minus 10 percent; grounding the pin falls back to the 520 mA internal limit, which folds back with input to output differential. PWRGD is open drain and reports the output at 90 percent of nominal with 1.6 percent of hysteresis.

Supply and substitution

H grade parts are the thinnest line in this family at distribution, because the automotive and avionic programs draw on the same test capacity. Files that need the hot end are best kept on one cross reference so the I, H and MP options are visible in one place, which is what the power management cross reference shows. Short lines are worked on the BOM shortage recovery page, and the cost of moving between grades is set out on the component cost page.