Contact Us

HMC-AUH317-Die

Brand: Analog Devices
Analog Devices HMC-AUH317-Die is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HMC-AUH317-Die — Analog & Mixed-Signal ICs | Superb Automation

HMC-AUH317-Die

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The HMC-AUH317-Die from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

HMC-AUH317 die: 22 dB at 81 GHz to 86 GHz from 0.64 W of DC

The HMC-AUH317 is a three stage gallium arsenide HEMT medium power amplifier die covering 81 GHz to 86 GHz with 22 dB of gain, 17.5 dBm at one decibel compression, 19.5 dBm saturated and 9 dB of input return loss, from two 4 V drains at 80 mA each. The die measures 2.65 mm by 1.6 mm by 0.05 mm and the bond pads and the backside are titanium gold. Every published figure comes from probed die rather than from a packaged part, which makes this one of the few order codes where the table describes exactly what a customer receives.

Published values

ParameterValue
Frequency range81 GHz to 86 GHz
Gain19 dB minimum, 22 dB typical
Input return loss9 dB typical
Output return loss5 dB typical
Output power at 1 dB compression17.5 dBm typical
Saturated output power19.5 dBm typical
Supply4 V on two drains, 80 mA each, 160 mA total
Gate biasVGG1 and VGG2 adjustable minus 0.8 V to plus 0.3 V, minus 0.1 V typical
Die size2.65 mm by 1.6 mm by 0.05 mm
Backside and padstitanium gold
Measurement basisprobed die at 25 degrees

A 5 dB output return loss is a constraint on the next stage, not a fault

Five decibels of output return loss means a voltage standing wave ratio of about 3.5 to 1, so roughly a third of the incident wave comes back. At 85 GHz the amplifier is a single stage block that cannot be conjugately matched without loss, and the vendor has chosen output power over match. The consequence is that whatever follows has to tolerate that reflection without turning it into ripple in the passband, and an isolator at 85 GHz is expensive and lossy.

The practical answer is a short bond and a well matched next stage. A 0.05 mm ribbon 0.15 mm long is about 0.05 nanohenry, which is 27 ohm at 85 GHz, so the bond itself is part of the matching network and its length has to come from the vendor's assembly drawing rather than from a rule of thumb. A bandpass filter directly at the output of this die will see the reflection and its own stopband will move, which is why the filter is usually placed after a buffer or a pad.

Point six four watts on a 4.24 square millimetre die at 0.05 mm thick

4 V at 160 mA total is 0.64 W of DC. At the 17.5 dBm compression point the output is 56 mW, so 0.58 W becomes heat on a die face of 2.65 mm by 1.6 mm, which is 0.14 W per square millimetre. A 50 micrometre substrate has almost no lateral spreading, so that heat leaves through the backside into the attach and from there into the carrier.

At these frequencies the carrier is usually copper tungsten or a similar expansion matched alloy, and the attach is a gold tin eutectic or a sintered silver layer of controlled thickness. The thickness matters electrically as well as thermally: at 85 GHz the ground reference is the backside, so a bond line that is 25 micrometres instead of 10 changes the impedance seen by the transistor. That is why the assembly drawing specifies the attach and not just the die.

Two gates, both of which have to be set

Both VGG1 and VGG2 are adjusted independently between minus 0.8 V and plus 0.3 V, with minus 0.1 V typical, to reach 80 mA in each drain. Two gates and two drains means two bias networks and, in practice, two current measurements. A build that sets both gates to the typical voltage and hopes will end up with a die that conducts more or less than intended, and at 0.58 W of dissipation a 20 percent current error is a 30 degree junction temperature error.

The die is supplied in a gel pack and handled as known good die only if the customer pays for the screening. Nothing in the document describes a burn in or a visual standard beyond the outline, so an incoming inspection on a 2.65 mm die is limited to what a microscope shows. For a module build the practical control is to measure gain and current after bonding on the first few units of each lot, because a die that is damaged in handling usually shows as a gain loss rather than as a current fault.

Two pages worth reading before a purchase order goes out are the RF component sourcing page and how to choose an RF amplifier; the first lists what else fits the socket, the second is the test sequence for a drop in, and defense grade components covers the case where the shortage is already on the line.

Two questions buyers ask

Does the 5 dB output return loss mean the part is defective? No. It is the specified match at 85 GHz, and it means the next stage has to tolerate a reflection of about a third of the incident wave.

Are the figures measured on die or in a package? On probed die at 25 degrees, so the table describes the part as delivered, before any assembly adds transition loss.