ADXL1003BCPZ-RL7
Product Specifications
ADXL1003BCPZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADXL1003BCPZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADXL1003BCPZ-RL7: 45 Micrograms per Root Hertz Up to 15 kHz
The ADXL1003BCPZ-RL7 is a single axis MEMS accelerometer with an analogue output, a plus and minus 200 g full scale range, a linear response from dc to 15 kHz and a noise density of 45 micrograms per root hertz. It is built for bearing fault detection, where the signature of a failing race is a burst of energy at a high frequency that a lower bandwidth sensor never sees. Buyers reach this page when a condition monitoring node has been specified and the sensor bandwidth turns out to be the limit.
What the part contains
One in plane sensing axis, a ratiometric analogue output, an overrange indicator and a full electrostatic self test, in a 5 mm by 5 mm by 1.8 mm LFCSP. The mechanical response is flat from dc to 15 kHz, the resonant frequency sits at 28 kHz, and the die survives 10,000 g of external shock without losing its repeatable sensitivity. Sensitivity stability over temperature is within 5 percent, linearity is within 0.2 percent of full scale and cross axis sensitivity is 1 percent. Supply range is 3.0 V to 5.25 V, operating current is 1.0 mA, there is a standby mode with a fast recovery, and the part is rated from -40 C to +125 C.
Key parameters
| Parameter | Value |
|---|---|
| Axis | Single, in plane |
| Full scale range | Plus and minus 200 g |
| Linear bandwidth | Dc to 15 kHz, minus 3 dB |
| Resonant frequency | 28 kHz typical |
| Noise density | 45 micrograms per root hertz typical |
| Sensitivity stability over temperature | Within 5 percent |
| Linearity | 0.2 percent of full scale |
| Cross axis sensitivity | 1 percent |
| Shock survival | 10,000 g |
| Output | Analogue, ratiometric to supply |
| Supply voltage | 3.0 V to 5.25 V |
| Supply current | 1.0 mA, standby mode available |
| Package | 32-lead LFCSP, 5 mm by 5 mm by 1.8 mm |
What the numbers mean on a board
Forty five micrograms per root hertz across a 15 kHz band integrates to 5.5 mg rms, which is 27.6 parts per million of a 200 g full scale range. No 16 bit converter can resolve that: 200 g across 65,536 codes is 3.05 mg per code, so the sensor noise is under two codes and the converter is the limit, not the sensor. The interesting consequence is that a cheaper converter with a narrower band can be the right choice, because the extra bandwidth of this sensor is wasted if the digital side stops at 1 kSPS.
The 15 kHz band against a 28 kHz resonance is the margin that keeps the measurement honest. A rigid mounting keeps the resonance at 28 kHz and the response flat to 15 kHz. A bracket with its own mode at 12 kHz will show a bump inside the measurement band, and that bump moves with temperature and bolt torque. The overrange flag is the signal that the mounting is moving, not that the machine is failing, and distinguishing those two is the whole job of a condition monitoring node.
One milliamp at 5 V is 5 mW, so an analogue output sensor plus a converter is a practical battery or loop powered node. The 5 percent sensitivity stability is the number that decides whether the node needs a calibration channel: 5 percent on a 200 g range is 10 g of apparent offset at full scale, which for a bearing trend is large. Either calibrate at the supply the node actually runs, or excite the sensor from the same reference the converter uses so the ratiometric relationship cancels the drift.
Where it is used
- Bearing and gearbox fault detection on rotating machinery
- Predictive maintenance nodes on pumps and fans
- Health and usage monitoring on airframes and rotating assemblies
- Acoustic emission measurement
- Test fixtures that need a dc coupled response to 15 kHz
Sourcing notes and next step
Condition monitoring programmes run for a decade, so continuity and date code matter more than price on this part. The sensitivity is trimmed at the factory and does not survive a reflow profile hotter than the data sheet allows, which is why a sealed reel from a franchised channel is worth more here than on a logic device. A cut tape quantity is usually enough for a pilot, and a partial reel from a cancelled build is the fastest route when a machine is down.
Sensor and converter sets for a monitoring board are collected in BOM shortage recovery, and parts with a long life commitment are listed on the obsolete and long life hub. The rest of the catalogue is on the analog and mixed signal family page. Send the range, the mounting arrangement and the date you need it and we come back with stock, date code and reel status the same day.
ADXL1003BCPZ-RL7: what 45 micrograms per root hertz buys at the bandwidth a machine needs
Noise density is only useful once it is integrated over the band the application actually watches. At 45 micrograms per root hertz, a 1 kHz band gives 1.42 mg RMS, a 5 kHz band gives 3.18 mg, and the full 15 kHz linear range gives 5.51 mg, each of them the density multiplied by the square root of the bandwidth. Against a plus or minus 200 g range that is a dynamic range of about 100,000 to 1 at 1 kHz, which is a little over 16 bits, and about 36,000 to 1 at 15 kHz, which is a little over 15 bits. Both are arithmetic on quoted figures, and both are the number that matters when a bearing defect sits a few milligrams above the noise floor.
Range, shock and the sensitivity tolerance over temperature
The sensitivity is stable within plus or minus 5 percent over temperature. On a plus or minus 200 g range, 5 percent of full scale is 10 g, so an absolute reading of 2 g moves by up to 100 mg across the temperature window even though the noise floor is 45 micrograms. That is the reason condition monitoring programs normalise against a baseline captured at a known temperature rather than trusting the absolute amplitude. The 10,000 g shock immunity and the overrange indicator are the other half of the same story: the part survives the event that would destroy a lower range sensor, and the OR pin says that the measurement in that window is not usable.
| Item | Published value | Arithmetic or meaning |
|---|---|---|
| Range | Plus or minus 200 g | 400 g span, so one 16 bit code is 6.1 mg |
| Noise density | 45 micrograms per root hertz | 5.51 mg RMS over 15 kHz |
| Linear band | dc to 15 kHz typical | Resonance at 28 kHz sits outside the band |
| Linearity | Plus or minus 0.2 percent of full scale | 0.4 g on a 200 g range, 65 codes at 16 bits |
| Cross axis | Plus or minus 1 percent | 2 g of the wrong axis on a 200 g reading |
| Supply current | 1.0 mA typical | 5 mW at 5 V, 44 Wh over a year |
| Output | Ratiometric to supply | A converter sharing the supply reference cancels the drift |
Dc coupling and fast recovery are what make it a monitoring part
An ac coupled sensor loses the static component, and a bearing monitor needs both: the static load and the defect signature. Dc coupling plus overrange sensing gives a channel that recovers quickly after a shock instead of sitting in a long settling tail, which is what allows a node to keep sampling through the event that made the measurement interesting. The self test pin is a factory level check rather than a calibration, and it is worth having on a node that is bolted to a machine in a place nobody wants to visit.
Sensing parts for a monitoring board sit alongside their converters on the analog and mixed-signal ICs index, a factory sealed reel matters more than price on a trimmed sensor and the sourcing route for that is BOM shortage recovery, and long life parts are planned through component lead time solutions.
Request Quote — In Stock, 100% New & Original, Full Warranty