ADUM3471WARSZ-RL7
Product Specifications
ADUM3471WARSZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADUM3471WARSZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADuM3471WARSZ-RL7: four channels and 2 W of isolated power in one 20 lead body
What this order code is
ADuM3471WARSZ-RL7 is the ADuM3471 in the 20-lead SSOP body, automotive qualified, on a reel. It combines a quad channel digital isolator with three channels forward and one reverse, a PWM controller and a transformer driver for an isolated dc to dc converter that delivers up to 2 W at an adjustable 3.3 V to 24 V from a 5 V or 3.3 V input, with 70 percent efficiency at the guaranteed 400 mA load into 5 V.
The point of the part is board area and part count: a 2 W isolated supply usually means a controller, a transformer driver, four signal isolators and a pile of passives, and this integrates the first two with the third. The transformer is still external, and the transformer is where most of the remaining engineering risk sits.
Parameters as published
| Item | Value |
|---|---|
| Signal channels | 4, three forward and one reverse |
| Data rate | dc to 25 Mbps NRZ |
| Isolated output power | 2 W |
| Output voltage | 3.3 V to 24 V adjustable |
| Efficiency | 70 percent at 400 mA into 5 V |
| Switching frequency | 200 kHz to 1 MHz, adjustable |
| Isolation test | 2500 V RMS for 1 minute |
| Working voltage | 560 V peak |
| Temperature | 105 C maximum |
| Protection | cycle by cycle overcurrent, thermal shutdown |
| Start up | soft start |
| Body | 20-lead SSOP |
Numbers that decide the application
Two watts at 70 percent is 2.86 W in, so the part and the transformer together dissipate 0.86 W and the input draws 571 mA from a 5 V rail at full load. That input current is the number that decides the upstream supply, the input capacitor and the trace width, and it is three times what a buyer expects when reading 400 mA at the output. A 3.3 V input at the same output needs 866 mA, which is beyond many small 3.3 V housekeeping rails.
The switching frequency range is the transformer selection axis. At 200 kHz a transformer needs a larger core for the same power, at 1 MHz it needs less copper and produces more core and switching loss, and the efficiency figure of 70 percent is quoted at one operating point rather than across the range. The 2 W is also a thermal rating as much as an electrical one: 0.86 W in a 20-lead SSOP is a rise of perhaps 60 to 80 C depending on the copper under it, which leaves little room in a 105 C cabinet. Derating to 1 W or 1.5 W is normal in a sealed enclosure.
25 Mbps is a 40 ns bit, and the isolated supply is not a limit on the data channels, which run on their own coupling. The 560 V peak working voltage is 396 V RMS against a 2500 V RMS one minute test, so the barrier is a basic insulation level for a low voltage system and not a mains barrier. The soft start and the cycle by cycle current limit exist because the transformer primary looks like a short at power up, and a board that omits the recommended soft start capacitor sees the overcurrent limit trip on every cold start.
Where it fits and where it does not
It fits a field bus node that needs isolated power and isolated signalling in one body, an isolated RS-485 or RS-232 interface, a gate drive bias where the barrier is inside the product, and an automotive or industrial board where the qualified part is required. It does not fit a load above 2 W, a mains referenced barrier, a board that needs more than four signal channels, or an enclosure at 105 C with the full load, where the dissipation has to be derated first.
Supply and second source questions
Three fields decide substitution here: the channel direction combination, the 2 W power class, and the automotive qualification. The family also ships versions with a different mix of forward and reverse channels and a version without the integrated converter, and those parts do not cover the same job. The transformer is a second sourcing question in its own right, because the turns ratio and the primary inductance belong to the converter and not to the isolator. The isolator families are listed on the second source page.
Sourcing notes and next step
We quote the code with the body and the qualification, and we ask for the isolated output voltage and current, because the 2 W is a ceiling and not a working point. Send the line items, quantities and required date through the BOM shortage recovery page and we will answer with availability. The wider interface list sits on the analog and mixed signal IC page.
Request Quote — In Stock, 100% New & Original, Full Warranty