ADUM1441ARQZ
Product Specifications
ADUM1441ARQZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADUM1441ARQZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADuM1441ARQZ: the 3 in 1 out quad isolator for a loop powered board
The ADuM1441ARQZ is a four channel digital isolator in a 16-lead QSOP, with three channels running from side 1 to side 2 and one running back, rated -40 to +125 C. It is the micropower member of the iCoupler range: the data sheet quotes microamps per channel rather than milliamps, which is why it turns up on 4 mA to 20 mA loop boards, battery instruments and any board that cannot afford a millamp per signal. The 1441 code is also the point where two package options split the isolation rating, and that split is the usual reason a purchase order lands on the wrong line.
Published values
| Parameter | Value |
|---|---|
| Channels | Four, three inputs on the VDD1 side and one input on the VDD2 side |
| Maximum data rate | 2 Mbps NRZ |
| Maximum propagation delay | 180 ns at 3.3 V |
| Quiescent current, refresh enabled | 5.6 uA per channel typical at 3.3 V |
| Quiescent current, refresh disabled | 0.3 uA per channel typical at 3.3 V |
| Dynamic current | 148 uA per Mbps per channel typical at 3.3 V |
| Same figures at 2.5 V | 3.1 uA refresh on, 0.1 uA refresh off, 117 uA per Mbps |
| Isolation, 16-lead QSOP | UL 1577 2500 V rms for one minute, VIORM 565 V peak |
| Isolation, 20-lead SSOP | UL 1577 3750 V rms for one minute, VIORM 645 V peak |
| Transient immunity | Above 25 kV per microsecond |
| Default output state | High on the 1440 to 1442 codes, low on the 1445 to 1447 codes |
| Temperature | -40 C to +125 C, all codes |
| Package and suffix | 16-lead QSOP, option RQ-16; Z is RoHS, RL7 is 7 inch tape and reel |
Where 2 Mbps and 180 ns actually meet
At 2 Mbps a bit is 500 ns wide, so the 180 ns maximum delay takes 36 percent of one bit before the receiving end has looked at it. On a 1 MHz SPI bus the clock period is 1000 ns and the round trip through two channels is 360 ns, which leaves 640 ns for the setup and hold of the far device. That is the arithmetic to run before treating this part as a drop in for a 25 Mbps isolator.
The refresh setting changes the current by a factor of about nineteen: 5.6 uA per channel with refresh enabled against 0.3 uA without. Refresh is what holds a static line at the correct level when the input has not moved, so it is the setting to keep on any bus with an idle state. Turning it off suits a continuously toggling clock, not a chip select.
The isolation figure follows the package, not the part number
The same 1441 die appears as ARQZ in a 16-lead QSOP at 2500 V rms and 565 V peak, and as ARSZ in a 20-lead SSOP at 3750 V rms and 645 V peak. The SSOP is the body that carries the 60601-1 medical listing on the data sheet, while the QSOP lists 60950-1. A substitution between the two keeps the channel count and the 2 Mbps rate and changes both the board area and the approval basis.
The family also carries intrinsic safety certification as a group, II 1G Ex ia IIC Ga, which is a system level claim that only holds while the exact order code on the certificate is used. For an instrument that goes into a hazardous area, the code on the reel is part of the certification, not a purchasing preference.
When an order code in this family cannot be found, the pin to pin cross reference lists what else does the same job, the ADI second source page covers what to check before a part is dropped into an existing board, and how to verify a drop in replacement is the route we take on a live shortage.
Two questions buyers ask
Is the ADuM1441ARQZ automotive qualified? No. The W codes carry that qualification. This code is screened -40 to +125 C, which is a wide industrial range but not a qualification, and a customer who needs the AEC document needs the W part number.
Can the refresh be switched off to save the microamps? Only on a line that keeps switching. With refresh off the quiescent current falls from 5.6 to 0.3 uA per channel, but a static chip select then depends on refresh to stay at a defined level, so the saving is real only on a clock.