ADP3605ARU-3
Product Specifications
ADP3605ARU-3
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADP3605ARU-3 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADP3605 as a 120 mA inverting rail: what the charge pump can and cannot do
The ADP3605 is a 120 mA switched capacitor voltage inverter with a regulated output, running from a single positive supply of 3 V to 6 V and producing a negative rail without an inductor. The family output is adjustable over -3 V to -6 V with two resistors, the accuracy is plus or minus 3 percent, and the output switching frequency is 250 kHz from a 500 kHz internal oscillator. It is the cheapest way to get a small negative rail, and the efficiency arithmetic is what decides whether it is the right way.
Published values
| Parameter | Value |
|---|---|
| Output current | 120 mA |
| Output voltage | adjustable -3 V to -6 V; the -3 suffix on this page is the fixed -3 V member |
| Input voltage | 3.0 V to 6.0 V |
| Output accuracy | plus or minus 3 percent |
| Output switching frequency | 250 kHz nominal from a 500 kHz oscillator |
| External inductor | none, two capacitors and one flying capacitor |
| Shutdown current | 2 microamp typical |
| Package | 8-lead SOIC |
| Ambient range | -40 to +85 degrees C |
Efficiency is set by the input voltage, not by the part
An inverting charge pump can at best deliver an output equal to minus the input, so the efficiency ceiling is the ratio of the two. From 5 V to -3 V that ceiling is 60 percent, from 3.6 V it is 83 percent, and from 6 V it is 50 percent. A 6 V input is the worst case in the published range and it is also the case where a buyer expects a charge pump to be efficient because the current is small.
The loss is the difference between the input and output multiplied by the load current. At 120 mA, 5 V to -3 V burns 0.24 W and 6 V to -3 V burns 0.36 W, which in an 8-lead SOIC is the number to check against the thermal resistance before the part is chosen for a 6 V bus.
Where the input is close to the output the part is genuinely good: 3.6 V to -3 V at 120 mA loses 72 mW and delivers 360 mW, and a 3.3 V rail feeding a -3 V requirement is the case this topology was built for.
The switch carries twice the output current
In a switched capacitor inverter the flying capacitor charges from the input while the output is supplied from the output capacitor, so the peak current through the switches is about twice the output current. At 120 mA that is 240 mA of peak switch current, and the input capacitor has to supply it in bursts at 250 kHz.
Output ripple follows the same relation: the load current divided by the product of switching frequency and output capacitance. 120 mA at 250 kHz across 4.7 microfarad gives about 102 mV of ripple, so a converter front end that needs a quiet negative rail still needs a post filter or a low dropout regulator after the pump.
Which order code is on the shelf
The current ordering guide lists ADP3605ARZ and ADP3605ARZ-R7, both adjustable, and the -3 suffix printed on this page refers to the fixed -3 V member of the earlier ordering information. A purchase order therefore has to quote the suffix as well as the base number, and the fixed version's availability has to be confirmed against the vendor's current ordering information rather than assumed from the page title.
Functionally the two are the same converter: the adjustable code sets the output with two resistors, and on the fixed code that divider is inside. Substituting one for the other on an existing board means adding or removing those two parts, so it is a change to the bill of materials rather than a drop in.
Two pages worth reading before a purchase order goes out are BOM shortage recovery and the obsolete part cross reference hub; the first lists what else fits the socket, the second is the test sequence for a drop in, and how to verify a drop in replacement covers the case where the shortage is already on the line.
Two questions buyers ask
Does the ADP3605 need an inductor? No. It needs an input capacitor, an output capacitor and one flying capacitor, which is the reason it is used where an inductor is unacceptable, such as a very thin board or a shielded enclosure that cannot take a magnetic field.
Can it invert a 5 V rail to -5 V? The published output range stops at -6 V and the input range stops at 6 V, so -5 V from 5 V sits at the edge of both. Any tolerance on the 5 V rail takes the output out of regulation, so -3 V from 5 V is the practical case in this family.