Contact Us

ADN4650BRWZ-RL7

Brand: Analog Devices
Analog Devices ADN4650BRWZ-RL7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADN4650BRWZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

ADN4650BRWZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADN4650BRWZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADN4650BRWZ-RL7: An LVDS Link That Survives 5 kV Across the Barrier

The ADN4650BRWZ-RL7 is a dual channel LVDS isolator that runs at 600 Mbps with 5 kV rms of galvanic isolation. It replaces a discrete LVDS driver, a digital isolator and a receiver with one part, which is why it appears wherever a fast differential link has to cross an isolation barrier: analog front ends in medical equipment, data plane links between a hot side and a cold side, and isolated clock and data runs in industrial drives.

What the part contains

Two LVDS channels in either transmit or receive orientation, built on a transformer isolation technology and compliant with the TIA/EIA-644-A LVDS standard. Propagation delay is 4.5 ns maximum, peak to peak total jitter is 151 ps at 600 Mbps, pulse skew is 100 ps and part to part skew is 600 ps. The part runs from 2.5 V or 3.3 V, with an on chip regulator that makes 2.5 V from a 3.3 V rail, and it delivers -75 dBc of supply ripple rejection with glitch immunity. The barrier is rated to plus and minus 8 kV of IEC 61000-4-2 contact discharge across it, and common mode transient immunity is above 25 kV per microsecond. The 20-lead SOIC version gives 5 kV rms and 7.8 mm of creepage, the SSOP version gives 3.75 kV rms in a smaller body.

Key parameters

ParameterValue
Channels2, transmit or receive
Data rate600 Mbps maximum
Isolation, SOIC5000 V rms for one minute
Isolation, SSOP3750 V rms for one minute
Working voltage600 V peak per VDE 0884-17
Propagation delay4.5 ns maximum
Total jitter at 600 Mbps151 ps peak to peak maximum
Pulse skew100 ps maximum
Common mode transient immunityAbove 25 kV per microsecond
Supply2.5 V or 3.3 V
Package20-lead SOIC wide body or 20-lead SSOP
Temperature range-40 C to +125 C

What the numbers mean on a board

At 600 Mbps one bit lasts 1.667 ns. The 4.5 ns maximum delay is 2.7 bit periods, which is latency, not a bit error source, and 151 ps of jitter is 9 percent of a bit, which is the number that eats margin in a receiver. Pulse skew of 100 ps is 6 percent of a bit, and if both channels carry a clock and data pair, that skew is what has to be added to the setup and hold budget of the receiving device.

The 600 V peak working voltage is the figure that matters for a product that has to run for years, and 5 kV rms for one minute is a type test, not an operating condition. In medical equipment the barrier is usually specified against IEC 60601-1, and this part carries that approval along with 62368-1 and 61010-1. The 7.8 mm of creepage on the SOIC body is the reason to choose it over the SSOP when the pollution degree is 2 and the working voltage is high.

Above 25 kV per microsecond of common mode transient immunity is what keeps a link alive when a motor drive switches. A 100 ns edge across a 1 kV barrier is 10 kV per microsecond, so the part has about 2.5 times the margin of the fastest edge a 600 V drive can produce. That margin is the difference between a link that survives a brake chopper and one that drops a frame.

Where it is used

  • Isolated analog front ends in patient connected medical equipment
  • Data plane isolation between hot and cold sides of a drive
  • Isolated clock and data links in test and measurement
  • SPI transported over LVDS across a barrier
  • Industrial imaging links where the sensor sits at a different potential

Termination, fail-safe and the isolation barrier in practice

LVDS needs a 100 ohm termination at the receiver, and this part integrates the receiver on one side of the barrier so the termination sits at the far end of the cable, not at the isolator. A link that works on the bench and fails in the cabinet usually has the termination missing or doubled. The fail-safe mechanism in this family holds a logic high on the driver output when the receiver inputs are open, shorted or terminated but not driven, which prevents a floating pair from producing random transitions.

The barrier itself is a transformer, so it passes a common mode transient as a displacement current rather than blocking it. That is why the 25 kV per microsecond figure is quoted rather than the isolation voltage alone: a drive with a fast switching node can produce a transient that a 5 kV barrier passes without a breakdown but with a bit error. Route the barrier across a slot in the ground plane where possible, keep the two grounds apart, and do not run a copper pour under the package.

Sourcing notes and next step

Isolation parts are bought against a certification file, so the part number must match the certificate exactly. The SOIC and SSOP bodies carry different ratings and are not interchangeable, and a substitution from one to the other invalidates the safety file even though both are the same silicon. Keep the order code intact and ask for the date code: a 2020 reel has lost five years of its shelf life in a barrier that is rated by thickness and dielectric, not by age, but the solderability has not.

Signal chain parts on the other side of the barrier are collected on the ADC and DAC cross reference page, and the exact procedure for confirming a substitute in a certified socket is in how to verify a drop in replacement. The rest of the catalogue is on the analog and mixed signal family page. Send the barrier voltage, the data rate and the package you are certified for and we confirm stock against that order code.

Request Quote — In Stock, 100% New & Original, Full Warranty