ADM2582EBRWZ-REEL7
Product Specifications
ADM2582EBRWZ-REEL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADM2582EBRWZ-REEL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADM2582EBRWZ-REEL7: signal and power isolation in one 20-lead body, 256 nodes on the bus
The ADM2582EBRWZ-REEL7 is an Analog Devices isolated RS-485 and RS-422 transceiver with an integrated isolated dc-to-dc converter, configurable as half or full duplex, in a 20-lead wide body SOIC. It combines a three channel isolator, a three-state differential driver and a differential receiver with an iso Power converter, so a single 5 V or 3.3 V supply on one side of the barrier powers both sides. Data rate is 16 Mbps, the bus supports up to 256 nodes, the RS-485 pins carry plus or minus 15 kV of ESD protection, and the receiver has open and short circuit fail-safe inputs. Common mode transient immunity is above 25 kV per microsecond. Regulatory approvals are UL 1577 at 2500 V rms for one minute, CQC GB4943.1, and a working voltage of 524 V peak under VDE 0884-17. It is on the analog and mixed-signal IC line card.
256 nodes is a statement about receiver loading, not about cable length
The RS-485 standard defines a unit load, and 32 unit loads is the classic limit. A part that allows 256 nodes on one bus presents one eighth of a unit load, which is why the same two wires can carry eight times as many transceivers. The trade is that the receiver input impedance is eight times higher and the noise margin depends on the termination and on the stub length, so a 256 node bus is a topology that has to be laid out as a daisy chain rather than as a star. The 16 Mbps rate gives a bit period of 62.5 ns, and at that rate a 100 m bus is already a transmission line question, not a dc one.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Isolation | 2500 V rms for one minute, UL 1577 | 3536 V peak withstand against 524 V peak working |
| ESD on the bus pins | plus or minus 15 kV | 29 times the working voltage of the barrier |
| Data rate | 16 Mbps | 62.5 ns bit period |
| Bus loading | 256 nodes | one eighth of a standard unit load each |
| Supply | 5 V or 3.3 V, one side powered | no external isolated dc-to-dc block |
| Common mode immunity | above 25 kV per microsecond | a 1 kV step across the barrier in 40 ns is rejected |
| Package and temperature | 20-lead wide SOIC, -40 C to +85 C | 7.5 mm body for the creepage the barrier needs |
The converter inside is the part that decides the thermal budget
An isolated transceiver without an integrated converter needs a separate isolated supply, which is usually a transformer, a driver and a rectifier, and takes more board area than the transceiver itself. Integrating the converter removes those parts and their certification, at the cost of a switching regulator running inside the package. That converter is the main heat source, and the 20-lead wide body is the heat path. For a bus node in a sealed enclosure the supply current at 16 Mbps is the number to check against the ambient, not the quiescent figure.
Selection notes
- The 524 V peak working voltage is not the 2500 V rms withstand figure; the first is continuous and the second is a one minute test, and the ratio between them is 6.7.
- Fail-safe receiver inputs guarantee a defined output when the bus is open or shorted, which prevents a node from reporting a permanent start bit.
- Thermal shutdown protects the driver during a bus contention fault, and it releases when the fault is removed, so a controller must not treat the event as permanent.
- Half or full duplex is set by the wiring of the same part, so one order code covers both bus arrangements.
Questions buyers ask
Does the integrated converter remove the need for a separate isolated supply? Yes for the transceiver side. If the node also needs isolated power for other circuits, a larger iso Power part or an external converter is still needed.
Is 16 Mbps usable over 100 m of cable? At 16 Mbps a 100 m cable is several bit periods long, so termination, stub length and cable skew set the limit. The transceiver is capable at that rate, the wiring decides whether the link works.
Isolated interfaces are frequently substituted between nodes of the same bus, and the checks are on pin to pin cross reference and how to verify a drop in replacement.
Request Quote — In Stock, 100% New & Original, Full Warranty