ADG5413FBRUZ-RL7
Product Specifications
ADG5413FBRUZ-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADG5413FBRUZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADG5413FBRUZ-RL7: two normally open and two normally closed in one body
The ADG5413FBRUZ-RL7 is a quad single-pole single-throw switch with fault protection and detection, 10 ohm on resistance and 0.5 ohm of flatness, in a 16-lead TSSOP. Two channels are normally open and two are normally closed, so a single logic line gives a complementary pair. Analog signal range extends from VSS to VDD, digital inputs are 3 V compatible over the whole supply range, and the switch holds a known state when the digital supplies are absent. Overvoltage protection and power-off protection both reach plus or minus 55 V, the human body model rating is 5.5 kV, and the part is latch-up immune. Dual supply covers plus or minus 5 V to plus or minus 22 V, single supply 8 V to 44 V, with full specification at plus or minus 15 V, plus or minus 20 V, 12 V and 36 V. It is listed in the analog and mixed-signal IC line card with the rest of the switch range.
The channel arrangement is the feature
Four independent switches would need four control lines. Two normally open plus two normally closed means two lines give four states with a guaranteed complement, which is what a gain select or a filter tap pair needs: one line switches channel A on and channel B off at the same instant, without a software step in between.
| Quantity | Figure | What it means in a signal path |
|---|---|---|
| On resistance | 10 ohm | 1 percent error into 1 kohm, 0.1 percent into 10 kohm |
| Flatness | 0.5 ohm | 0.05 percent into 1 kohm over the signal range |
| Channels | 2 normally open, 2 normally closed | one logic line per complementary pair |
| Fault protection | plus or minus 55 V, powered or not | field wiring can stay live with the card unplugged |
| ESD, human body model | 5.5 kV | above the 4 kV of the channel protector in the same family |
| Logic | 3 V compatible | no level shifter from a 3.3 V controller |
| Supply | plus or minus 5 V to plus or minus 22 V dual, 8 V to 44 V single | 24 V and 48 V industrial buses need the single-supply range checked |
Known state without supplies, and the fault threshold
When no supplies are present the switch stays off and the inputs are high impedance. That is a different guarantee from a plain CMOS switch, which can float its state and present a low impedance path through the body diodes. On a card that is inserted into a live rack, the state during the insertion interval is exactly when the guarantee matters.
The fault threshold is internal and fixed. When a source pin exceeds VDD or VSS by the threshold, the channel turns off and the signal is blocked up to 55 V relative to ground. The detection is on the source side, so the fault is caught at the pin where the field wiring arrives rather than after the switch.
Selection notes
- Single supply 8 V to 44 V covers a 24 V loop, but a 48 V bus sits above the 44 V ceiling and needs the dual-supply arrangement or a different part.
- The TSSOP body has no exposed pad; the thermal path for a channel carrying continuous current is the lead frame, so the current has to stay inside the package rating.
- Break-before-make is not the mechanism here because the channels are independent; the two normally open and two normally closed channels can still overlap if the logic line changes during a conversion, so the switch timing belongs in the acquisition window.
- Latch-up immunity under any condition removes the supply sequencing requirement that a standard CMOS switch carries.
Questions buyers ask
Can the four channels be used as two changeover pairs? Yes. One normally open and one normally closed channel share a logic line, so two lines control two complementary pairs, which is the usual gain select arrangement.
What happens if the analog input exceeds the supply? The channel turns off at the threshold and blocks up to 55 V relative to ground, whether or not the supplies are present. That is the fault protected behaviour that separates this part from a standard switch.
What should a quote request include? The order code, the supplies, the signal range, the fault voltage and the load behind the switch. Send the BOM line to the pin-to-pin cross reference when the part replaces a non-protected switch on an existing footprint, and to the shortage and continuity desk for current stock and the factory date code.
Request Quote — In Stock, 100% New & Original, Full Warranty