ADE7878ACPZ-RL
Product Specifications
ADE7878ACPZ-RL
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADE7878ACPZ-RL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
ADE7878ACPZ-RL: 0.1 percent over a thousand to one, and what that leaves at 33 mA
The ADE7878ACPZ-RL is an Analog Devices three phase energy metering IC that measures active, reactive and apparent energy on each phase and on the total system, in both the total and the fundamental only forms, and supplies rms readings as well. It contains second order sigma delta converters, a digital integrator, the reference and a fixed function processor whose program is in internal ROM, so no firmware is needed for the metering arithmetic. Accuracy is better than 0.1 percent over a 1000 to 1 dynamic range and better than 0.2 percent over 3000 to 1 at 25 C, the part supports current transformers and di over dt sensors, and it is qualified against EN 50470-1 and 50470-3 and IEC 62053-21, 22 and 23. Communication is by SPI or I2C plus a high speed data capture port, three pulse outputs carry the energy information, and the part is in a 40-lead LFCSP. The vendor marks it not recommended for new designs. It is on the analog and mixed-signal IC line card.
Three thousand to one is where a class 0.5S meter is decided
On a 100 A service, 1000 to 1 reaches down to 100 mA and 0.1 percent of that is 100 uA. At 3000 to 1 the bottom of the range is 33.3 mA and the error allowance is 0.2 percent, which is 67 uA. Those two numbers are what separate a class 1 meter from a class 0.5S meter: the accuracy at the bottom of the range is a current measurement problem, and it is set by the converter's noise against a shunt or a current transformer whose output at 33 mA is millivolts or less.
| Parameter | Vendor figure | Derived figure |
|---|---|---|
| Phases and wires | 3 phase, 3 or 4 wire, delta or wye | one part configures for either service |
| Accuracy, 1000 to 1 | below 0.1 percent at 25 C | on a 100 A service, 100 uA at 100 mA |
| Accuracy, 3000 to 1 | below 0.2 percent at 25 C | 67 uA of error allowance at 33.3 mA |
| Quantities | total and fundamental active, reactive, apparent, plus rms | four energy registers per phase and for the system |
| Standards | EN 50470 and IEC 62053-21, 22, 23 | covers class 1 and class 0.5S work |
| Sensors | current transformers and di over dt coils | Rogowski coils need the digital integrator |
| Interfaces | SPI, I2C and a high speed capture port | waveform access without polling the registers |
| Power quality | sag and swell, overcurrent, line period, phase angle | events available to the meter's own firmware |
| Package | 40-lead LFCSP | a single package for the whole metering chain |
The pulse outputs and the waveform registers serve two different customers
The three pulse outputs are what a revenue meter's calibration bench uses: a known energy is applied and the pulse count is compared with the reference. The waveform sample registers and the capture port are what an engineer uses when the same meter has to explain a harmonic problem, because they expose the converter outputs rather than the accumulated energy. A part that offers only the pulse output cannot answer the second question, and a part that offers only the registers cannot be calibrated against a reference meter.
Selection notes
- Per phase gain, phase and rms offset calibration means three sets of coefficients, and a meter that skips the phase calibration will fail at low power factor where the error is largest.
- The fixed function core in ROM removes the metering firmware from the certification scope, which shortens a meter approval rather than a product launch.
- Three low power modes keep the energy accumulation running during a tamper event, which is the state a meter is in when the cover is removed.
- The part is not recommended for new designs, so a new meter platform should start from the vendor's current family, and an existing one needs a stock plan rather than a substitution.
Questions buyers ask
Can it work with a Rogowski coil? Yes. The coil output is a derivative of current, and the digital integrator on the part is what turns it back into a current proportional signal.
Is the accuracy figure valid over temperature? The vendor quotes the 0.1 and 0.2 percent figures at 25 C, so a meter specification over the full range has to add the drift of the external shunt or transformer, which is usually the larger term.
Metering parts are compared with their converters on ADC DAC cross reference, and the checks that decide whether a substitute is safe are on how to verify a drop in replacement.
Request Quote — In Stock, 100% New & Original, Full Warranty