ADA4077-1ARZ
Product Specifications
ADA4077-1ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADA4077-1ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADA4077-1ARZ: the single A grade precision amplifier in 8-lead SOIC
The ADA4077-1ARZ is the single channel member of the ADA4077 family in an 8-lead SOIC, A grade. Analog Devices publishes 50 microvolts of maximum offset at 25 degrees C and 0.55 microvolts per degree C of maximum drift for this code. That places it in the replacement path for OP07, OP77 and OP177 sockets that have to lose the offset trim potentiometer without changing the pinout. The numbers below are the published ones, followed by what they turn into at the temperature extremes a transmitter or an RTD front end actually reaches.
Published values
| Parameter | Value |
|---|---|
| Channels | 1 |
| Package | 8-lead SOIC (R-8) |
| Offset voltage, A grade | 50 uV maximum at 25 C |
| Offset voltage drift, A grade | 0.55 uV/C maximum, 8-lead |
| Input bias current | 1 nA maximum at 25 C |
| Voltage noise density | 6.9 nV/root Hz typical at 1 kHz |
| CMRR, PSRR, open loop gain | 120 dB minimum each |
| Gain bandwidth product | 3.9 MHz typical at 5 V supply |
| Supply current | 400 uA per amplifier typical, 650 uA maximum |
| Absolute maximum supply | 36 V |
| Operating temperature | -40 C to +125 C |
| Moisture sensitivity | MSL1 rated |
| Grade | A (B grade is a separate order code) |
What 50 microvolts is against a 100 millivolt shunt
A 100 millivolt shunt read at a non inverting gain of 101 puts the offset straight into the measurement: 50 microvolts becomes 5.05 millivolts at the output, which is 0.05 percent of full scale before anything else is counted. The B grade code halves that to 25 microvolts and 2.525 millivolts, but it is a different line item with a different price, and a BOM that quotes the A grade cannot be filled with a B grade without the customer accepting the change.
The same arithmetic applies to a thermocouple front end at a gain of 100. The amplifier is rarely the dominant error at room temperature, but it is the one error that does not average down with filtering, which is why the offset figure is the first number to put in front of the customer when a channel fails calibration.
Where the drift budget goes over the published span
The published span is 165 kelvin, from minus 40 to plus 125 degrees C. At 0.55 microvolts per degree C the drift term reaches 90.75 microvolts across that span, which is larger than the room temperature offset itself. The B grade at 0.25 microvolts per degree C reaches 41.25 microvolts. Any calibration done at 25 degrees C and nothing else is therefore incomplete by roughly twice the offset the customer was quoted.
This is the number to quote when a customer compares the ADA4077 against a chopper amplifier. The chopper wins on drift by three orders of magnitude, and the ADA4077 wins on bandwidth and on supply range. Both statements are true at the same time, and which one matters depends on whether the loop is calibrated once at room temperature or trimmed in production.
Current, headroom and the 36 volt ceiling
At 650 microamps maximum per amplifier and a 15 volt rail the package dissipates about 19.5 milliwatts before any load current is counted. Driving 10 volts into 2 kilohms draws 5 milliamps and dissipates 50 milliwatts in the load, so the load and not the quiescent current decides the thermal question. The 36 volt absolute maximum supply leaves room for a plus minus 15 volt rail with margin, but not for a 36 volt single supply running at the top of its tolerance.
Input bias current of 1 nanoamp maximum matters more than it looks on a high impedance source: across a 100 kilohm resistor it is 100 microvolts, twice the offset specification of the part. Where the source impedance cannot be lowered, the bias current sets the error floor and the offset grade stops being the limiting factor.
When an order code in this family cannot be found, the ADI second source page lists what else does the same job, how to verify a drop in replacement covers what to check before a part is dropped into an existing board, and BOM shortage recovery is the route we take on a live shortage.
Two questions buyers ask
Is the A grade enough instead of the B grade? It depends on what the customer calibrates. At 25 degrees C the difference is 50 microvolts against 25; across the full 165 kelvin span it is 90.75 microvolts against 41.25. A channel calibrated at room temperature only will see the second number at the temperature extremes.
Does the 1 nanoamp bias current matter with a 100 kilohm source? Yes. One nanoamp through 100 kilohms is 100 microvolts of error, which is twice the offset specification, so on that source the bias current and not the grade is the number to size the channel around.