Contact Us

AD8366ACPZ-R7

Brand: Analog Devices
Analog Devices AD8366ACPZ-R7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD8366ACPZ-R7 — Analog & Mixed-Signal ICs | Superb Automation

AD8366ACPZ-R7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD8366ACPZ-R7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

AD8366ACPZ-R7: 63 Gain Steps and a Noise Figure That Follows the Code

The AD8366 is a matched pair of differential digitally controlled variable gain amplifiers, covering dc to 600 MHz with a 3 dB bandwidth and dc to 150 MHz at 2 V peak to peak, with a gain range of 4.5 dB to 20.25 dB in 0.25 dB steps. Each channel is set separately or both together, over a serial or parallel control port. Noise figure is 11.4 dB at 10 MHz at maximum gain and 18 dB at minimum gain, output third order intercept is 45 dBm at 10 MHz, and second and third order distortion are better than minus 90 dBc for a 2 V peak to peak output at 10 MHz into 200 ohm. The input is 200 ohm differential, the output about 25 ohm, the supply 5 V at 180 mA typical, and the body a 32-lead LFCSP with an exposed pad. The vendor lists one part model and a 1ku price starting at $8.43.

Sixty three steps over 15.75 dB

The gain range is 15.75 dB in 0.25 dB steps, which is 63 steps and a linear gain from 1.7 to 10.3. A 0.25 dB step is 1.029 in voltage, so a code change moves the output by about 2.9 percent. That granularity is what allows the part to be used as an automatic gain control element without a second fine attenuator, and it is fine enough that the step itself is below the level accuracy of most converters behind it.

Noise figure rises as the gain falls

The vendor states 11.4 dB at maximum gain and 18 dB at minimum, and describes the rise as about 2 dB for every 4 dB of gain reduction. The minimum gain setting is therefore the worst noise case, and it is the one that matters when the input is weak. This is the opposite of the intuition that a variable gain stage is quietest when it is turned down, and it is the reason an automatic gain control loop is arranged to run at high gain whenever the signal allows.

The published table, as the vendor states it

ParameterValue
Channels2, matched pair
Gain range4.5 dB to 20.25 dB
Gain step0.25 dB, 63 steps
Bandwidth600 MHz at 3 dB, dc to 150 MHz at 2 Vpp
Noise figure at 10 MHz11.4 dB at maximum gain, 18 dB at minimum
Output intercept, 10 MHz45 dBm
Distortion at 2 Vpp out, 10 MHzbetter than minus 90 dBc, HD2 and HD3
Input impedance, differential200 ohm
Output impedance, differentialabout 25 ohm
Output common modedefaults to half the supply, programmable
Supply5 V, 180 mA typical, 3 mA disabled
Temperatureminus 40 C to 85 C
Package32-lead LFCSP with exposed pad

Seven decibels of output against 900 mW of supply

Two volts peak to peak into 200 ohm is 5 mW, which is 7 dBm. The part draws 900 mW to deliver it. That ratio is not a fault: the product is linearity and a matched pair, not efficiency. The 45 dBm intercept sits 38 dB above the test tone, which is the margin that lets a 12 or 14 bit converter behind it see a clean signal rather than the amplifier's own products.

The exposed pad is part of the circuit

900 mW in a 32-lead LFCSP leaves the package through the exposed pad, so the pad has to be soldered to a thermal land with vias, not left floating on a paste stencil. A board that treats the pad as mechanical will run the part hot and see the gain drift before it sees a failure.

Selection notes

  • Both channels in one package are matched, which removes a gain and phase alignment step between the I and Q paths.
  • The output common mode is programmable, so the part can drive a converter at its own reference level without a transformer.
  • An optional dc offset correction loop removes offset from the stages ahead; it can be disabled for dc coupled use.
  • Cascading two parts at maximum gain adds only 0.04 dB of noise figure, because the first stage gain suppresses the second.

Buyer questions

Is the 600 MHz figure usable at full swing? No. The 600 MHz is the small signal 3 dB bandwidth; at 2 V peak to peak the vendor specifies dc to 150 MHz. A receiver that needs full swing at high frequency should work from the second figure.

Can the two channels be set to different gains? Yes. The control port addresses them separately, and the serial mode allows both to be updated together when the pair has to track.

Family page for the category: Analog and mixed-signal ICs. For RF signal chain parts see RF component sourcing, and for amplifier families see amplifier cross reference.

AD8366ACPZ-R7: what a quarter decibel step is worth in an automatic gain loop

Sixty three steps of 0.25 dB over a 15.75 dB range is a finer resolution than most converters behind the part can resolve, and that is the point: the step is not there to be used as an attenuator, it is there to let a loop settle without hunting. A 0.25 dB step is a factor of 1.029 in voltage, so one code moves the output by 2.9 percent, and the loop can be brought to within 1.5 percent of its target without a second fine control. The price is 900 mW of supply and a noise figure that is worst at the bottom of the range.

ItemValueWhat it does to a loop
Gain range4.5 dB to 20.25 dB15.75 dB of authority, 63 steps of 0.25 dB
Step size0.25 dB, 2.9 percent in voltageA loop settles inside 1.5 percent without a fine stage
Noise figure11.4 dB at maximum gain, 18 dB at minimumThe bottom of the range is the worst noise case, not the best
Output intercept45 dBm at 10 MHzAt 20 dBm out the third order products are 30 dB down
Supply5 V at 180 mA900 mW, and the exposed pad is the only path for it
Impedance200 ohm differential in, about 25 ohm outThe output needs a transformer or a matching network before a filter

Linearity arithmetic that a link budget can use

An output intercept of 45 dBm places the third order products by the usual relation: three times the output level minus twice the intercept. At 20 dBm of output the products land 30 dB down, at 10 dBm they land 60 dB down, and the part is therefore comfortable well below its compression point. The number to remember is that every decibel of output costs two decibels of linearity, so a system that needs 40 dB of spurious free range at 10 MHz should not run this part above about 12 dBm of output.

The low gain state is the noisy one

Noise figure rises from 11.4 dB at maximum gain to 18 dB at minimum, roughly 2 dB for every 4 dB of gain reduction, which is backwards from the intuition that turning a stage down makes it quieter. An automatic gain loop therefore runs at the highest gain that does not overload the converter behind it, and it uses the 63 steps to stay there rather than to sit in the middle of the range. A receiver that parks at mid scale for headroom pays 4 to 6 dB of noise figure for the habit.

Nine hundred milliwatts and a quarter watt per channel

Five volts at 180 mA is 900 mW for the pair, 450 mW per channel, and the 32 lead LFCSP with an exposed pad is the only thermal path. The output common mode defaults to half the supply and can be driven, so the part can be direct coupled to a converter that wants a different common mode, and the 25 ohm differential output is closer to a current mode interface than to a 50 ohm line. The range this part sits in is listed on the analog and mixed signal line card, an alternative with the same pin function is checked through pin to pin cross reference, and reel and date code confirmation is on the lead time page.