Contact Us

AD7927BRUZ

Brand: Analog Devices
Analog Devices AD7927BRUZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7927BRUZ — Analog & Mixed-Signal ICs | Superb Automation

AD7927BRUZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7927BRUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7927BRUZ: Eight 12-Bit Channels at 200 kSPS on 3.6 mW

The AD7927BRUZ is an eight channel, 12 bit successive approximation converter in a 20-lead TSSOP, running from a single supply of 2.7 V to 5.25 V at 200 kSPS. The grade matters here: it is specified at 69.5 dB minimum signal to noise and distortion with a 50 kHz input on a 3 V rail, and 70 dB typical, which is about 11.3 effective bits against the 74 dB an ideal 12 bit converter would show. That gap is the honest description of the part: the twelfth bit carries noise, and a system that needs a clean 12 bit reading either averages or uses a slower converter. Power is 3.6 mW maximum at 200 kSPS on 3 V and 7.5 mW on 5 V, and the serial interface runs from a separate VDRIVE pin so a 3.3 V processor can talk to a converter whose analog supply is 5 V.

Published values

ParameterValue
Resolution12 bit, no missed codes
Throughput200 kSPS maximum
Analog inputsEight single ended, with channel sequencer
Supply2.7 V to 5.25 V
Logic supplyVDRIVE, 2.7 V or 5 V systems independent of AVDD
Power3.6 mW max at 200 kSPS on 3 V, 7.5 mW max on 5 V
Supply current1.2 mA max on 3 V, 1.5 mA max on 5 V
SINAD69.5 dB min at 50 kHz on 3 V, 70 dB typical
SNR and THD69 dB min SNR, 70 dB min THD, minus 77 dB typical
Input bandwidth8.2 MHz typical track and hold
Aperture jitter50 ps typical
Shutdown0.5 uA maximum

What 69.5 dB of SINAD means for the code

Signal to noise and distortion of 69.5 dB is 11.25 effective bits, so the last code of a 12 bit result is mostly noise and the converter behaves like an 11 bit part with a spare bit of oversampling headroom. On a 2.5 V reference one 12 bit code is 610 uV, and with the internal range set to twice the reference for a 5 V span it is 1.22 mV, so the noise floor of the part sits around a third of a code in either case. That is fine for a control loop, a multi-channel monitor or a battery powered instrument where the reading is averaged over ten or a hundred samples. It is not enough for a single shot precision measurement, where the 50 ps of aperture jitter and the 8.2 MHz track and hold bandwidth are the real limit rather than the bit count.

Conversion time is set by the serial clock, not by the part

The conversion time is 800 ns with a 20 MHz serial clock and scales with it, because the same clock is the conversion master clock. A 200 kSPS cycle is 5 us, so 800 ns of conversion leaves about 4.2 us for acquisition and for reading the result out, which is comfortable. Drop the serial clock to 10 MHz and conversion grows to 1.6 us, which still fits, but a host that only manages 5 MHz turns the part into a 120 kSPS converter. This is the first thing to check when a board that worked with one microcontroller shows a lower reading rate with another: the throughput belongs to the bus, not to the converter.

The sequencer, and the per channel rate nobody quotes

Eight single ended inputs at 200 kSPS is not eight channels at 200 kSPS. Scanning all eight gives 25 kSPS per channel, which is 40 us per channel and plenty for temperature, pressure and supply monitoring. The sequencer lets the host program a shorter sequence, so a system that needs three fast channels and five slow ones can cycle the three at 66 kSPS and pick up the rest on a slower schedule without a second converter. The configuration register also selects straight binary or twos complement coding, which is what makes a bipolar input around a mid-scale reference readable without a software offset.

Shutdown behaviour in a battery instrument

Full shutdown takes the part to 0.5 uA maximum, against 1.2 mA maximum while converting on a 3 V rail. A sensor node that samples at 1 kSPS uses one conversion in two hundred, so the average current is dominated by the wake up time rather than by the conversion itself, and the sleep current decides the battery life. On a 2000 mAh cell, 0.5 uA is 4.4 mAh a year, which is smaller than the self discharge of most cells. The catch is that the reference and the input signal have to be settled again after each wake up, so the first reading after power up should be discarded. The ADI part second source page lists the grades that share this pinout, the pin to pin cross reference page covers the eight channel family, and the lead time page shows what is on the shelf for a build that ships this quarter.