Contact Us

AD7730BRUZ

Brand: Analog Devices
Analog Devices AD7730BRUZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD7730BRUZ — Analog & Mixed-Signal ICs | Superb Automation

AD7730BRUZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD7730BRUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD7730BRUZ: 230,000 Counts From a Load Cell, and the Drift Numbers Behind That Claim

The AD7730BRUZ is a complete front end for weigh scales and pressure transducers: a two-channel programmable gain modulator, a programmable digital filter, a six-bit digital to analogue converter for tare removal, and clock outputs for alternating current bridge excitation, all on a single +5 V supply in a 24-lead TSSOP. The headline is 230,000 counts peak to peak, and the number that decides whether that headline survives a real instrument is the offset drift of 5 nV per degree C. On a 10 mV full scale span, 230,000 counts is about 87 nV per count, so 5 nV per degree C is 5.7 percent of one count per degree C, or roughly six counts across a 100 degree swing. That is a real error in a 1 in 230,000 instrument and it is why the part is specified for drift over time as well as at 25 degrees.

Ranges, gain and what one count is worth

The part accepts four unipolar ranges from 0 to 10 mV up to 0 to 80 mV and the matching four bipolar ranges, so the full scale is chosen at the input rather than by an external amplifier. On the 10 mV bipolar range a count is 87 nV, on the 80 mV range it is 696 nV, and the same 5 nV per degree C of offset drift is a smaller fraction of a count the wider the range. That is the trade in one sentence: the narrowest range gives the finest resolution and the worst drift in counts, and the widest range gives the best drift margin and the coarsest resolution. A load cell with a 2 mV per V sensitivity on a 5 V excitation produces 10 mV at full load, which puts it on the narrowest range and therefore on the least favourable side of that trade.

Tare removal and alternating current excitation

The on-chip six-bit converter subtracts a tare voltage of up to 80 mV from the input, with a resolution of 1.25 mV when the reference is 2.5 V and 2.5 mV when it is 5 V. That is coarse compared with the converter resolution on purpose: it removes the bulk of the dead load so that the analogue gain can be spent on the live range, and the fine tare is done numerically after conversion. The clock outputs for alternating current excitation matter in bridge work because reversing the excitation removes the thermal EMF of the bridge and the offset drift of the amplifier from the measurement, at the cost of a slower update and a settling requirement on each polarity. Line frequency rejection of more than 150 dB is the other half of the same story: with a programmable filter set to the mains frequency, the pickup that dominates a 10 mV signal is removed before it reaches the host.

ParameterValue on this order codeWhat it decides
Resolution230,000 counts peak to peak, 24 bits no missing codes87 nV per count on the 10 mV range
Offset drift5 nV per degree CSix counts across a 100 degree swing on 10 mV
Gain drift2 ppm per degree C0.02 percent over 100 degrees
Input ranges10, 20, 40 and 80 mV, unipolar and bipolarFull scale set at the input, no external gain stage
Line rejectionMore than 150 dBMains pickup removed by the digital filter
Tare converter6 bits, up to 80 mV, 1.25 mV at 2.5 V referenceDead load removed in the analogue path
ExcitationClock outputs for alternating current bridge driveThermal EMF and amplifier offset cancelled
SupplySingle +5 VOne rail for the bridge and the converter
Package24-lead TSSOPBU suffix, the SOIC and DIP bodies also exist

Filter, update rate and the settling trap

The digital filter cutoff and output rate are programmed through registers, and the peak to peak resolution moves with both of them and with gain. A slow output rate with a narrow filter gives the 230,000 count figure, and a faster rate gives fewer counts, which is normal for a sigma-delta converter and easy to forget when a specification is written from the front page. The other trap is settling: a filter that rejects the mains frequency has a settling time measured in tens of milliseconds, so a multiplexed weigh scale that hops between two channels has to allow that time after every channel change or it will report the previous channel's tail. The two-channel front end is intended for exactly that pattern, and the settling allowance is the reason the update rate per channel is not the converter's frame rate.

Where the part fits and what to compare

Weigh scales, pressure and strain transducers, and any low frequency measurement where the signal of interest is smaller than the noise floor of a general purpose converter belong here. Where the measurement needs more channels or a faster rate, the ADC and DAC cross reference lists the sigma-delta family by resolution and channel count, and the ADI part second source page sets out the fields that have to match before an alternative is approved for a production scale. For a build that combines this front end with the rest of an instrument BOM, the one stop BOM sourcing page covers the combined order.