AD7124-4BRUZ
Product Specifications
AD7124-4BRUZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD7124-4BRUZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD7124-4BRUZ: a 24-bit four channel converter in 24-lead TSSOP
The AD7124-4BRUZ is the four channel member of the AD7124 family in a 24-lead TSSOP. It publishes three power modes, up to 22 noise free bits at a gain of 1, and an output data rate from 1.17 samples per second up to 19200 samples per second depending on the mode. For a temperature or bridge channel the interesting number is not the 24 bit resolution but the noise in nanovolts at the data rate the process actually runs at.
Published values
| Parameter | Value |
|---|---|
| Resolution | 24 bit |
| Inputs | 4 differential |
| Package | 24-lead TSSOP (RU-24) |
| Low power mode | 24 nV rms at 1.17 SPS, gain 128, 255 uA typical |
| Mid power mode | 20 nV rms at 2.34 SPS, gain 128, 355 uA typical |
| Full power mode | 23 nV rms at 9.4 SPS, gain 128, 930 uA typical |
| Noise free resolution | up to 22 bits at gain 1 |
| Output data rate, full power | 9.38 SPS to 19200 SPS |
| Output data rate, mid power | 2.34 SPS to 4800 SPS |
| Output data rate, low power | 1.17 SPS to 2400 SPS |
| Mains rejection | simultaneous 50 Hz and 60 Hz at 25 SPS, single cycle settling |
| Supply | 2.7 V to 3.6 V analog, 1.8 V interface supply |
| Power down current | 5 uA maximum |
| Operating temperature | -40 C to +125 C |
Noise free bits is the number to quote, not 24
A 24 bit converter with a 2.5 volt reference has one least significant bit at 149 nanovolts. The part publishes up to 22 noise free bits at a gain of 1, which puts the noise free code at about 596 nanovolts, so the low four bits of a 24 bit word are noise and the customer who asks for 24 bit accuracy is asking for something the part does not promise.
At a gain of 128 the published noise is 24 nanovolts rms in low power mode, which referred to the input is 0.1875 microvolts. That is a real improvement for a thermocouple, whose signal is tens of microvolts per degree, and it is why the gain stage is worth using instead of a wider reference.
The three modes are a current budget, not a speed setting
Low power draws 255 microamps typical and reaches 2400 samples per second; full power draws 930 microamps and reaches 19200. The ratio between the two supply currents is 3.65, while the noise at the same gain moves from 24 to 23 nanovolts, so paying for full power buys speed and almost no noise improvement. A channel that only needs 10 samples per second should stay in low power mode and take the 255 microamps.
The mode also changes the digital filter, which is why the output data rate ranges differ. If a process is qualified at 25 samples per second with simultaneous 50 and 60 hertz rejection, changing the mode changes the filter and the qualification has to be repeated.
Mains rejection at 25 samples per second
Simultaneous rejection of 50 and 60 hertz at 25 samples per second with single cycle settling is the feature that lets a temperature channel ignore the mains without an external notch filter. Twenty five samples per second is a 40 millisecond period, and one cycle of settling means the channel is usable for a multiplexed scan at that rate without discarding a conversion after each channel change.
At the top of the full power range, 19200 samples per second is a 52.08 microsecond period and the mains rejection is gone. The two ends of the range are for different jobs, and a requirement that mentions both 50 hertz rejection and 19200 samples per second is a requirement that has not been thought through.
When an order code in this family cannot be found, the ADI second source page lists what else does the same job, how to verify a drop in replacement covers what to check before a part is dropped into an existing board, and BOM shortage recovery is the route we take on a live shortage.
Two questions buyers ask
Is the AD7124-4 a true 24 bit converter? It is a 24 bit converter with up to 22 noise free bits at a gain of 1, which is about 596 nanovolts of noise free code against a 2.5 volt reference. The low bits carry noise.
Can it run at 19200 samples per second with 50 Hz rejection? No. The simultaneous 50 and 60 hertz rejection is published at 25 samples per second. At 19200 samples per second the filter is much wider and the mains rejection is gone.