AD707ARZ
Product Specifications
AD707ARZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD707ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
AD707ARZ: 15 Microvolts of Offset and 0.1 Microvolt per Degree of Drift
The AD707ARZ is an ultralow drift operational amplifier whose published limits are 15 microvolts maximum input offset, 0.1 microvolts per degree Celsius maximum offset drift, 0.35 microvolts peak to peak maximum noise over 0.1 Hz to 10 Hz, 1 nA maximum input bias current, 130 dB minimum common mode rejection and 120 dB minimum supply rejection. Open loop gain is quoted at 8 volts per microvolt minimum, which is 138 dB, so the amplifier holds its closed loop accuracy even at high gain. Slew rate is 0.3 volts per microsecond and closed loop bandwidth is 0.9 MHz, which places it firmly in the precision band rather than the fast band. A dual version is available as the AD708, and the single is offered in TO-99, DIP, cerdip and surface mount bodies.
Published values
| Parameter | Value |
|---|---|
| Input offset | 15 microvolts maximum |
| Offset drift | 0.1 microvolts per degree Celsius maximum |
| Low frequency noise | 0.35 microvolts peak to peak maximum, 0.1 Hz to 10 Hz |
| Open loop gain | 8 volts per microvolt minimum, about 138 dB |
| Common mode rejection | 130 dB minimum |
| Supply rejection | 120 dB minimum |
| Input bias current | 1 nA maximum |
| Slew rate | 0.3 volts per microsecond |
| Closed loop bandwidth | 0.9 MHz |
| Dual version | AD708 |
| Bodies | TO-99, DIP, cerdip and surface mount |
Drift, not offset, is the specification that decides the grade of an instrument
A 15 microvolt offset can be trimmed out at production test and stays out if the amplifier does not move. The 0.1 microvolt per degree figure is what makes that trim last: over a 50 degree excursion the offset moves 5 microvolts, which is a third of the untrimmed limit and inside the resolution of most 16 bit systems. Compare that with a general purpose precision amplifier at 1 microvolt per degree, where the same excursion moves 50 microvolts and forces either a wider calibration window or a chopper. This is why the part appears in transducer amplifiers, precision references and instrument front ends that are calibrated once at the factory.
The cost of specifying this part by mistake
An ultralow drift amplifier with a 0.3 volt per microsecond slew rate is a poor choice for a signal that moves quickly: a 10 V step takes 33 microseconds to settle, and a 100 kHz signal is heavily distorted. Programs that specify it because the offset figure looks good, and then ask for 1 MHz of bandwidth, end up adding a second amplifier and a coupling network. The sensible split is a precision part for the dc path and a faster part for the ac path, and the AD707 belongs strictly in the first.
Bodies, grades and the TO-99 question
The package list includes a metal can, which is still ordered for instruments that are rebuilt rather than replaced, and the surface mount body is the volume option. Where the exact grade is unavailable, the drift figure is the one that has to be matched, not the offset: a substitution that doubles the drift undoes the calibration strategy even if the room temperature offset is better. The amplifier cross reference lists the precision op amp families we can supply, the ADI second source page covers grade equivalence, and the obsolete part cross reference hub covers codes that have reached end of life.