AD5245BRJZ100-RL7
Product Specifications
AD5245BRJZ100-RL7
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The AD5245BRJZ100-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
AD5245BRJZ100-RL7: two hundred and fifty six taps on a two wire bus
The AD5245 is a single-channel, 256-position digital potentiometer with an I2C-compatible interface, and the AD5245BRJZ100-RL7 order code reads B for the grade, RJ for the 8-lead SOT-23, Z for RoHS, 100 for a 100 kOhm end-to-end resistance and RL7 for the 7 inch reel. It is the compact member of the family: the package measures 2.9 mm by 3 mm, the supply range is 2.7 V to 5.5 V, and the part draws 8 microamp from that supply. The wiper register is both writable and readable over the bus, and a command bit can send the wiper to midscale or put the device into a zero power state.
What the vendor page states
| Parameter | Value |
|---|---|
| Positions | 256, single channel |
| End-to-end resistance | 100 kOhm on this order code, 5, 10 and 50 kOhm also offered |
| Interface | I2C compatible, with wiper register readback |
| Addressing | AD0 pin, up to two devices on one bus |
| Supply | 2.7 V to 5.5 V single supply |
| Supply current | 8 microamp |
| Temperature coefficient | 45 ppm per degree C |
| Power-on state | preset to midscale, settling 5 microsecond typical |
| Temperature | minus 40 C to plus 125 C |
| Package | 8-lead SOT-23, 2.9 mm by 3 mm |
Two devices per bus is the real limit
The AD0 pin is a package address decode input, and the vendor states plainly that it allows up to two devices on the same bus. A board that needs four independent trims therefore needs two buses, a bus switch, or a different part with a multi-drop interface. This is the kind of constraint that surfaces late, when a customer has already fixed the connector pinout, so it belongs in the first conversation. At 400 kHz, two bytes per wiper write take about 45 microsecond on the wire, which is fast enough that the bus is never the reason a calibration loop is slow. Readback matters more than speed here: being able to read the wiper register means a self test can confirm the trim actually landed instead of assuming it did.
8 microamp and 45 ppm per degree
Eight microamp at 2.7 V is 22 microwatt and at 5.5 V it is 44 microwatt, which is why this part appears in battery equipment where a mechanical trim pot would be replaced purely to remove a hand adjustment step. The temperature coefficient is 45 ppm per degree C, and over the full 165 C span from minus 40 C to plus 125 C that accumulates to 7,425 ppm, or 0.74 percent, which is 742 Ohm on a 100 kOhm ladder. That is a useful number when a customer asks whether the trim will hold across a cold start and a hot soak: the setting does not drift, the resistance does, and 0.74 percent over the entire military-to-industrial span is small compared with the 0.392 percent step, so the ratio between two positions stays close to what was written.
Midscale at power-on
The wiper is preset to midscale and settles in 5 microsecond typical on power-up, which means code 128 of 256 and therefore half of the end-to-end resistance before the host writes anything. For a bias or a threshold that is a safe default. For a gain that must start at a specific value, the host has to write inside the boot window, and the safest route is to hold the enable of the following stage low until the bus transaction completes. The vendor lists LCD panel common voltage, brightness and contrast control, transducer adjustment for pressure, temperature, position and optical sensors, and radio frequency amplifier biasing as applications, all of which are cases where the exact value matters less than the ability to adjust it in the field. Buyers comparing this device with the dual nonvolatile part can use the pin to pin cross reference to see which footprint fits, the bill of materials shortage recovery page for schedule cover, and the analog and mixed signal category page for the rest of the range.
Request Quote — In Stock, 100% New & Original, Full Warranty