Thermocouple and RTD Front Ends for Industrial Temperature Probes
Product Specifications

Product Overview
A thermocouple produces a few tens of microvolts per degree, and it produces them against a second junction where the lead meets the board. That second junction is the cold junction, and unless its temperature is measured the reading is wrong by the board temperature. A front end that integrates the cold junction sensor, its correction and a converter on one die removes three error terms at once: the sensor mismatch, the correction arithmetic and the drift between two separate packages.
An RTD works the other way round. Its resistance rises with temperature, the change is small, and the lead resistance sits in series with the element, so a two wire connection adds the cable to the measurement. A three wire connection cancels most of that error by measuring the drop on one lead, and a four wire connection removes it completely with a separate force and sense pair. The front ends on this page are specified for all three arrangements, and the conversion is a ratio between the element and a reference resistor, which is why the accuracy depends on the reference resistor as much as on the converter.
The third family is the simplest and still the most common in appliances and instruments: a sensor with an analog output of 10 mV per degree, which needs nothing but an ADC input. It has no cold junction, no linearisation and no digital interface, and its accuracy is set by the reference of the converter behind it. That is why the same package family appears in a 1 C thermostat and in a 0.5 C instrument, with the difference made by the ADC rather than by the sensor.
Key Specifications
| Parameter | Thermocouple front end | RTD front end | Analog output sensor |
|---|---|---|---|
| Sensor type | K, J, N, T, E, S, R | PT100 to PT1000, 100 ohm to 1 k at 0 C | on die sensor |
| Resolution | 14 bit, 0.25 C per count | 15 bit, 0.03125 C nominal | 10 mV per C, set by the ADC behind it |
| Accuracy | 2 C over -200 C to 700 C on the K version | 0.5 C total over all conditions | 0.5 C at 25 C, 1 C over the full range |
| Cold junction | sensed and corrected on the die | not applicable, ratiometric measurement | not applicable |
| Connection | two wire thermocouple, open and short detected | 2, 3 and 4 wire RTD, cable fault detected | two or three terminals |
| Interface | SPI, read only | SPI with fault registers | analog voltage output |
| Supply | 3.0 V to 3.6 V | 3.0 V to 3.6 V | 2.7 V to 5.5 V, or 4 V to 30 V on the LM35 |
| Package | SO-8 | TQFN-20 and SSOP-20 | TO-92, SOT-23 |
Included Models and Order Codes
The order codes below are the front ends quoted most often for ovens, autoclaves, plastic machinery, laboratory baths and process transmitters. State the sensor type, the temperature range, the wire count, the accuracy budget and the interface, and the front end and its reference resistor are confirmed together.
| Part Number | Sensor | Range | Resolution | Interface | Package |
|---|---|---|---|---|---|
| MAX31855KASA+ | K thermocouple | -200 C to 1350 C | 14 bit, 0.25 C | SPI, read only | SO-8 |
| MAX31855TASA+ | T thermocouple | -250 C to 400 C | 14 bit, 0.25 C | SPI, read only | SO-8 |
| MAX31865ATP+ | PT100 to PT1000 RTD | set by the reference resistor | 15 bit, 0.03125 C nominal | SPI with fault registers | TQFN-20 |
| MAX31865AAP+ | PT100 to PT1000 RTD | set by the reference resistor | 15 bit, 0.03125 C nominal | SPI with fault registers | SSOP-20 |
| DS18B20 | on die sensor | -55 C to 125 C | 9 to 12 bit, 0.0625 C | 1-Wire | TO-92 |
| LM35DZ | on die sensor | 0 C to 100 C | 10 mV per C | analog | TO-92 |
| TMP36GT9Z | on die sensor | -40 C to 125 C | 10 mV per C, 750 mV at 25 C | analog | SOT-23 |
| ADS1118IDGS | thermocouple with a PGA | set by the gain, up to plus or minus 6.144 V | 16 bit, 860 samples per second | SPI | VSSOP-10 |
| AD8495ARMZ | K thermocouple amplifier | -25 C to 400 C at 5 mV per C | analog, 5 mV per C | analog | MSOP-8 |
Key Features
Cold junction on the die – the reference junction sensor sits next to the input, so the correction uses the same temperature the terminals see and drifts with them.
Fault detection built in – an open thermocouple, a short to the supply and an open or shorted RTD are reported as flags, so a controller can tell a failed probe from a cold process.
Ratio measurement on RTD – the converter measures the element against a reference resistor, so the accuracy follows the resistor rather than the supply, which is why a 0.1 percent reference is quoted with the part.
Wire count flexibility – two, three and four wire RTD connections are supported by the same part, so a probe with a long cable can be compensated without a different front end.
Resolution and speed traded – the thermocouple parts resolve 0.25 C and the RTD part resolves 0.03125 C, and both give the conversion time so the loop rate can be planned.
Analog output simplicity – the 10 mV per C parts need no interface, no linearisation table and no calibration, which is why they still sit in appliances and panel meters.
PGA for small signals – the 16 bit converter brings a gain stage up to plus or minus 256 mV, which is enough to read a thermocouple directly with the cold junction measured on a second channel.
Supply range – 3.0 V to 3.6 V on the digital front ends and 2.7 V to 5.5 V on the analog sensors, so a 5 V board and a 3.3 V board can share the same sensor family.
Applications
These front ends are quoted for equipment that measures a probe rather than a board, typically where: The front end sits on the measurement board next to its terminals, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that board.
Ovens, furnaces and autoclaves – a K thermocouple reaches 1350 C, and the digital front end returns a linearised value with the cold junction already corrected, which removes the ice point reference from the panel.
Plastic and packaging machinery – a J or K thermocouple sits in a barrel or a seal bar, and the SPI output goes straight into the machine controller without an analog filter chain.
Laboratory baths and chillers – a PT100 in a three wire connection measures the bath, and the ratio measurement makes the reading independent of the cable resistance and the supply.
Appliances and panel meters – a 10 mV per C sensor with a 12 bit ADC gives a 0.5 C display without calibration, which is the arrangement behind most domestic and light commercial thermostats.
Sourcing and Cross-Reference
Temperature front ends fail in two ways that a part number does not show: the cold junction drifts away from the terminals, and the reference resistor changes value with temperature. A replacement with the same interface but a different reference arrangement can read correctly on the bench and drift in an enclosure, so the reference resistor and its tempco are part of the comparison, not an accessory.
For RTD inputs the wire count matters. A part qualified for four wire connection and a probe wired for two wire cannot be paired without changing the cable, and the fault detection thresholds are set for the arrangement the part expects. For thermocouples the type is part of the part number, because the linearisation curve and the connector colour code change with it, and a K type front end cannot read a J type probe correctly even with the same connector.
Availability on these parts is generally good, with the exception of the precision RTD front ends, which move with the mixed signal line. The quotation line states the sensor type, the wire count, the package and the batch date, and for a regulated product the accuracy of the individual lot is kept with the shipment record.
For volume builds, SUPERB Assembly support covers the cold junction copper balance, the terminal block torque and the reference resistor placement.
Q: Can you supply a thermocouple front end that keeps the same sensor type and interface?
A: Yes. Send the current part number, the sensor type, the range, the wire count and the interface, and the SUPERB Tech sales team will confirm the order code and the nearest part that keeps the sensor curve and the bus behaviour.
Why Buyers Source Temperature Front Ends Through SUPERB
- Sensor type held: the thermocouple type or the RTD wire count is matched before the interface, because the linearisation and the fault thresholds follow it.
- Reference resistor quoted: the resistor that sets the RTD accuracy is quoted with the front end, including its tempco, so the budget is closed at the first build.
- Fault flags verified: open and short detection is part of the acceptance, so a controller can distinguish a failed probe from a cold process.
- Lot accuracy recorded: regulated builds receive the accuracy of the individual lot, which is what a calibration certificate has to reference.