A load cell is a machined spring with four strain gauges bonded to it and wired as a Wheatstone bridge. The bridge is balanced when no load is applied, the gauges on the tension side rise in resistance and the ones on the compression side fall, and the difference appears as a millivolt output proportional to the load. Everything else in the data sheet follows from that: the rated output in millivolts per volt of excitation, the combined error over the rated capacity, and the temperature coefficients that describe how far the bridge drifts when the cell warms up.
Rated output is the first figure to match with the electronics. A 2.0 mV/V cell on a 5 V excitation gives 10 mV at full scale, which is a comfortable input for a 24 bit converter with a gain stage; a 0.6 mV/V miniature cell on the same excitation gives 3 mV, which needs a lower noise front end or a higher excitation within the cell rating. That is why the excitation range is quoted with the cell and why the analogue front end is chosen after the cell, not before.
Accuracy class carries more than the error figure. An OIML R60 C3 cell is verified over 3000 intervals with a stated minimum verification interval, and the class also fixes the creep, the temperature effect on zero and the temperature effect on span. A C5 cell is the same mechanical body sorted and tested to a tighter limit, so the price step buys repeatability at low load rather than a different cell.
The table below covers the groups we quote most often: single point aluminium cells from 50 kg to 500 kg in C3 to C5, a platform cell family up to 635 kg, parallel beam cells for small platforms, a miniature cell for 500 g, and 350 ohm foil gauges for builds where the spring is machined in house by the customer. Rated output, error, resistance, excitation and IP rating come from the maker data sheet for each code.
Key Specifications
| Parameter | Single point, C3 to C5 | Parallel beam, small platform | Miniature, 100 g to 1500 g |
|---|---|---|---|
| Capacity | 50 kg to 500 kg | 3 kg to 200 kg | 100 g to 1500 g |
| Rated output | 2.0 mV/V plus or minus 0.2 mV/V | 1.0 mV/V plus or minus 0.15 mV/V | 0.6 mV/V to 1.0 mV/V by capacity |
| Combined error | 0.023 percent to 0.014 percent of full scale | 0.05 percent of full scale | 0.05 percent of full scale |
| Creep over 30 minutes | 0.0167 percent to 0.010 percent of full scale | 0.05 percent of full scale over 3 minutes | 0.05 percent of full scale over 3 minutes |
| Input resistance | 406 ohm plus or minus 6 ohm | 1000 ohm plus or minus 15 ohm | 1090 ohm plus or minus 10 ohm |
| Output resistance | 350 ohm plus or minus 3 ohm | 1000 ohm plus or minus 10 ohm | 1000 ohm plus or minus 10 ohm |
| Excitation | 5 V to 12 V recommended, 18 V maximum | 5 V to 10 V | 6 V maximum |
| Safe overload | 150 percent of full scale | 120 percent of full scale | 150 percent of full scale |
| Ingress protection | IP65 | IP65 | IP65 |
| Element material | Aluminium alloy | Aluminium alloy or alloy steel by capacity | Aluminium alloy |
Included Models and Order Codes
The table lists the codes we quote most often. Capacity, accuracy class, rated output, error, resistance, excitation and IP rating come from the maker data sheet for that code. The accuracy class is part of the order code, so a C3 body and a C5 body of the same capacity are different codes and are not interchanged on a quotation.
| Part Number | Capacity | Class | Rated output | Combined error | Input / output | IP |
|---|---|---|---|---|---|---|
| L6E-C3-50kg-2B | 50 kg | C3, 3000 intervals | 2.0 mV/V | 0.023 percent FS | 406 ohm / 350 ohm | IP65 |
| L6E-C3-100kg-2B | 100 kg | C3, 3000 intervals | 2.0 mV/V | 0.023 percent FS | 406 ohm / 350 ohm | IP65 |
| L6E-C4-200kg-2B | 200 kg | C4, 4000 intervals | 2.0 mV/V | 0.0175 percent FS | 406 ohm / 350 ohm | IP65 |
| L6E-C5-500kg-2B | 500 kg | C5, 5000 intervals | 2.0 mV/V | 0.014 percent FS | 406 ohm / 350 ohm | IP65 |
| L6W-C3-635kg-3G6 | 635 kg | C3, 3000 intervals | 2.0 mV/V | 0.023 percent FS | 406 ohm / 350 ohm | IP65 |
| TAL220-5kg | 5 kg | not classified | 1.0 mV/V | 0.05 percent FS | 1000 ohm / 1000 ohm | IP65 |
| TAL220-50kg | 50 kg | not classified | 1.0 mV/V | 0.05 percent FS | 1000 ohm / 1000 ohm | IP65 |
| TAL221-500G | 500 g | not classified | 0.7 mV/V | 0.05 percent FS | 1090 ohm / 1000 ohm | IP65 |
| BF350-3AA | foil gauge, not a cell | gauge factor 2.0 to 2.2 | 350 ohm nominal | 0.1 percent resistance tolerance | not applicable | not applicable |
Key Features
Rated output matched to the front end – 2.0 mV/V on a 5 V excitation is 10 mV at full scale, and a 0.6 mV/V miniature cell gives 3 mV, so the converter and its gain are chosen from the cell output rather than the other way round.
Accuracy class carries the creep and the drift – a C3 cell is specified for creep, temperature effect on zero and temperature effect on span as well as for combined error, and the C5 body is the same outline tested to tighter limits.
Six wire or four wire stated – the L6E family is wired as a four conductor shielded cable with a 2 m tail, so the cable length and the shield connection are known before the junction box is planned.
Safe and ultimate overload given – 150 percent safe and 200 percent ultimate overload on the single point family set the mechanical stop on the platform, which is what protects the cell from a dropped load.
IP rating quoted with the body – IP65 on the aluminium cells covers dust and water jets, and the cable entry is the part that fails first, so the gland is quoted with the cell.
Foil gauges offered separately – 350 ohm constantan gauges with a gauge factor of 2.0 to 2.2 are listed for customers who machine their own spring and bond the bridge themselves.
Applications
These parts are quoted for weighing and force measurement, typically where:
Bench and platform scales – a single point cell under the platform corners carries 50 kg to 500 kg, and the C3 to C5 class sets how many display divisions the scale can legally show.
Filling and dosing machines – a 5 kg parallel beam cell reads the hopper weight, and the 0.05 percent combined error plus the 0.05 percent creep over three minutes sets the smallest dose the machine can repeat.
Force and tension measurement – a miniature cell at 500 g measures a spring or a roller force inside a machine, where the 6 V excitation limit and the 1090 ohm bridge suit a battery powered front end.
The cell connects to a front end on the same board, so it is quoted together with the SUPERB PCB and the SUPERB PCBA build for that board.
Sourcing and Cross-Reference
Selection starts with the mechanics. The capacity is set at about 1.5 to 2 times the working load, the platform size has to stay inside the maximum the cell allows, and the load introduction point has to sit on the cell axis. A cell that is oversized loses resolution and one that is undersized takes a permanent set on the first overload.
The second check is the electrical chain. Rated output, excitation, bridge resistance and cable length together decide the converter, its reference and its filtering; the temperature coefficients decide whether the scale needs a compensation step. Both are quoted with the cell so the front end is chosen once.
Where a cell has been discontinued, the substitution is checked on capacity, accuracy class, rated output, bridge resistance and the mounting hole pattern, because two cells with the same capacity can differ in height by several millimetres and that changes the platform. The route for these checks is on our obsolete part cross reference hub, and the drop in comparison is on pin to pin cross reference.
For volume builds, SUPERB Assembly support covers the shielded cable termination, the bridge filtering and the strain relief that keeps cable movement out of the reading.
Q: Can you supply a C3 single point load cell together with the matching 24 bit front end for a 3000 division scale?
A: Yes. Send the capacity, the platform size, the class required and the excitation available, and the SUPERB Tech team will confirm the rated output, the error, the bridge resistance and the mounting pattern from the maker data sheet before quoting.
Why Buyers Source Load Cells Through SUPERB
- Class quoted with the error: C3, C4 and C5 are given with the combined error, the creep and the interval count, so the scale resolution follows from the data sheet.
- Rated output matched to the front end: the millivolt per volt figure and the excitation range are quoted together, which is the pair that sets the converter gain.
- Mechanical data included: capacity, safe overload, platform limit and mounting pattern are given with the quotation, because a cell change moves the platform height.
- Foil gauges offered as well: customers who machine their own spring are quoted the 350 ohm gauge with its gauge factor and strain limit.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Sensors and detectors, Industrial pressure sensors and transducers, Instrumentation amplifiers for bridge signals, 24 bit delta sigma ADCs, 16 bit SAR ADCs, Obsolete part cross reference hub.