Instrumentation Amplifiers for Sensor and Bridge Signals
Product Specifications
Product Overview
A strain gauge bridge, a load cell or a pressure capsule produces a few millivolts of differential signal sitting on a common mode level that may be several volts away from ground, and often at the end of a cable that picks up mains and switching noise. An instrumentation amplifier is the block that separates the two: it takes the difference, rejects what the two inputs share, and refers the result to a reference pin that the ADC can use. The parts on this page are the three op amp and current feedback versions of that block, in packages from MSOP-8 to SOIC-8, with gain set by one external resistor.
The low power group is built around the INA333, a chopper stabilised part that runs from 1.8 V to 5.5 V on 50 microamps and still holds 25 microvolts of offset at a gain of 100 or more, with 0.1 microvolts per degree of drift and 50 nV per root hertz of noise. The AD8220 is the JFET input option for high impedance sources: 10 picoamps of bias current, 14 nV per root hertz, 1.5 MHz at unity gain, and a supply range of 4.5 V to 36 V single or plus or minus 2.25 V to plus or minus 18 V dual. The INA826 sits between them with 200 microamps of supply current, a 3 V to 36 V range, 150 microvolts of maximum offset and 18 nV per root hertz at high gain.
The precision and high speed group trades current for noise and bandwidth. The INA849 uses a current feedback topology to hold 8 MHz at a gain of 100 and 28 MHz at unity gain while keeping 1 nV per root hertz and 35 microvolts of offset, which is what a fast ADC driver or a photodiode front end needs. The AD8421 delivers 3.2 nV per root hertz from 2.3 milliamps and survives 40 V between an input and the opposite rail, so a miswired sensor does not end the board. The AD8221 keeps 80 dB of common mode rejection to 10 kHz, and the long running AD620, INA128 and INA118 cover gains up to 10,000 on plus or minus 2.25 V to plus or minus 18 V rails for boards that are already qualified around them.
Key Specifications
| Parameter | Low power and JFET input | Precision and high speed |
|---|---|---|
| Gain range | 1 to 1,000 on INA333, AD8220 and INA826 | 1 to 10,000 on INA849, AD8421, AD620 and INA118 |
| Gain setting | One resistor, G = 1 + 100 kOhm / RG on INA333 | One resistor, G = 1 + 6 kOhm / RG on INA849 |
| Input offset | 25 uV max on INA333 at G of 100 or more; 150 uV max on INA826 | 35 uV max on INA849; 0.2 uV per degree max drift on AD8421 |
| Voltage noise | 14 nV to 50 nV per root hertz | 1 nV to 9 nV per root hertz |
| Common mode rejection | 100 dB min on INA333 at G of 10 or more; 104 dB min on INA826 | 120 dB min on INA849 at maximum gain; 94 dB min on AD8421 at unity gain |
| Supply range | 1.8 V to 5.5 V single on INA333; 4.5 V to 36 V on AD8220 | Plus or minus 2.25 V to plus or minus 18 V; 8 V to 36 V single on INA849 |
| Bandwidth | 1.5 MHz at unity gain on AD8220; 150 kHz at unity gain on INA333 | 28 MHz at unity gain and 8 MHz at G of 100 on INA849; 10 MHz at unity gain on AD8421 |
| Quiescent current | 50 uA on INA333; 200 uA on INA826; 750 uA max on AD8220 | 2.3 mA max on AD8421; 6.2 mA on INA849 |
| Package | VSSOP-8, WSON-8, MSOP-8 | MSOP-8, SOIC-8, LFCSP-8, VSSOP-8 |
Included Models and Order Codes
The table lists the order codes most often quoted for weigh scales, transmitters, patient monitors and data acquisition boards. State the source impedance, the full scale differential signal, the supply rails and the gain, and the part, grade and packing are confirmed.
| Part Number | Gain Range | Voltage Noise | Supply Range | Package |
|---|---|---|---|---|
| INA333AIDGKR | 1 to 1,000 | 50 nV per root hertz at G of 100 or more | 1.8 V to 5.5 V single | VSSOP-8 |
| INA333AIDRGR | 1 to 1,000 | 50 nV per root hertz at G of 100 or more | 1.8 V to 5.5 V single | WSON-8 |
| AD8220ARMZ | 1 to 1,000 | 14 nV per root hertz at 1 kHz | 4.5 V to 36 V single, plus or minus 2.25 V to plus or minus 18 V dual | MSOP-8 |
| INA826AIDGKR | 1 to 1,000 | 18 nV per root hertz at G of 100 or more | 3 V to 36 V single, plus or minus 1.5 V to plus or minus 18 V dual | MSOP-8 |
| INA118U | 1 to 10,000 | 10 nV per root hertz at 1 kHz | Plus or minus 2.25 V to plus or minus 18 V | SOIC-8 |
| INA128U | 1 to 10,000 | 8 nV per root hertz at 1 kHz | Plus or minus 2.25 V to plus or minus 18 V | SOIC-8 |
| AD620ANZ | 1 to 10,000 | 9 nV per root hertz at 1 kHz | Plus or minus 2.3 V to plus or minus 18 V | PDIP-8 |
| AD8221ARMZ | 1 to 1,000 | 8 nV per root hertz at 1 kHz | Plus or minus 2.3 V to plus or minus 18 V | MSOP-8 |
| AD8421ARMZ | 1 to 10,000 | 3.2 nV per root hertz max at 1 kHz | Plus or minus 2.5 V to plus or minus 18 V, 5 V to 36 V single | MSOP-8 |
| INA849ID | 1 to 10,000 | 1 nV per root hertz at 1 kHz | 8 V to 36 V single, plus or minus 4 V to plus or minus 18 V dual | SOIC-8 |
Key Features
Drift that survives a warm cabinet – the INA333 holds 0.1 microvolts per degree at a gain of 100 or more, so a weigh scale does not walk away from zero after an hour of running.
One resistor sets the gain – G = 1 + 100 kOhm / RG on the INA333 and G = 1 + 6 kOhm / RG on the INA849, which keeps the gain network to a single 0.1 percent part instead of a matched resistor array.
JFET input for high impedance sources – 10 picoamps of bias current on the AD8220 means a 10 megohm sensor bridge or a pH electrode does not develop an offset across its own source resistance.
Bandwidth held at high gain – the current feedback INA849 still passes 8 MHz at a gain of 100, so a fast photodiode pulse is not smeared before it reaches the ADC.
Inputs that take a mistake – the AD8421 is protected to 40 V from the opposite supply and the INA118 to plus or minus 40 V, which covers a sensor wired to the wrong rail during commissioning.
Single supply down to 1.8 V – the INA333 runs from two alkaline cells with a rail to rail output, which keeps the analogue front end alive when the radio and the display are the only other loads.
Applications
These amplifiers are quoted for boards that measure a small differential signal in a noisy environment, typically where: A sensor board is normally quoted together with the SUPERB PCB and SUPERB PCBA work we support for the same assembly, so the amplifier, the gain resistor and the connector arrive as one kit.
Weigh scales and load cells – a 350 ohm bridge moves about 2 mV per volt of excitation at full load, so 10 microvolts of offset drift is a visible zero error and the chopper parts are the default.
Pressure and flow transmitters – a 4 mA to 20 mA loop transmitter has to hold its calibration from minus 40 to plus 85 degrees, and the low drift of the INA333 or the INA826 keeps the span error inside the loop budget.
Patient monitors and laboratory instruments – an ECG or biopotential front end needs high common mode rejection at 50 Hz or 60 Hz and a bias current low enough that the electrode offset does not saturate the first stage.
Sourcing and Cross-Reference
Instrumentation amplifiers are usually replaced for one of two reasons: the original part goes to end of life, or the noise and drift numbers no longer fit a tightened specification. Two parts with the same gain equation can differ in input bias current, in common mode range, in whether the reference pin is buffered, and in the package thermal pad, so a cross reference has to be checked against the circuit around it and not only against the pinout. We quote the gain equation, the offset and drift grade, the supply range and the package on every line.
The rest of the signal chain carries the same risk. A 0.1 percent gain resistor with a 25 ppm per degree temperature coefficient can dominate the drift of a chopper amplifier, and the RC filter in front of the inputs sets both the noise bandwidth and the input bias current path. We quote the amplifier, the gain resistor and the input filter as one set for a channel, so the error budget is calculated on parts that will actually be fitted.
Where the boards are built in volume, SUPERB Assembly support covers the SMT build and the inspection of the fine pitch MSOP and VSSOP parts.
Q: Can you supply pin compatible replacements for discontinued instrumentation amplifiers?
A: Yes. Send the current part number, the gain, the supply rails and the source impedance, and the SUPERB Tech sales team will confirm the order code, the grade and the nearest part that keeps the same gain equation and pinout.
Why Buyers Source Instrumentation Amplifiers Through SUPERB
- Grade and drift on the quote: the offset grade, the drift grade and the gain equation are stated per line, so the part matches the error budget rather than only the footprint.
- Amplifier and passives together: the gain resistor and the input filter for one channel are quoted with the amplifier, so the noise and drift figures are not estimates.
- Fine pitch assembly: MSOP, VSSOP and WSON parts are placed and inspected on the same line that supplies them, which keeps first pass yield visible.
- Long lifecycle supply: parts that an instrument was qualified around are held with date codes, so a product stays in production while an alternative is qualified.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Amplifiers and comparators, Precision operational amplifiers, Current sense amplifiers and shunt monitors, 16 bit SAR ADCs, Amplifier cross reference, Pin to pin cross reference.