Industrial Pressure Sensors and Transducers for Process Control
Product Specifications

Product Overview
A pressure reading is only as good as the band it was specified over. A sensor that holds 0.25 percent of full scale across 0 C to 50 C is a different part from one that holds the same figure across -20 C to 85 C, and the data sheet usually quotes both. The rows on this page keep the band with the number, so a 25 psi part that reads within 1.5 percent of full scale over its whole temperature range is not compared with a part quoted only at room temperature.
Output format decides the rest of the chain. A digital part with a 24 bit converter and calibrated coefficients goes straight to a microcontroller over I2C or SPI and needs no analog filter, no reference and no calibration step at the test bench. An analog ratiometric part needs an ADC input that shares its supply as the reference, because the output scales with the 5 V rail and an absolute reference would turn a supply drift into a pressure error.
Media compatibility is the third filter that removes most candidates. Dry air in a compressor line can use an open port. Condensing humidity, brake fluid, seawater or a cleaning agent needs a gel filled part with a stainless cap, and a differential part across a filter needs two ports with the same wetted material so that the two sides do not drift apart with temperature. The 30 bar part on this page is gel filled with an antimagnetic stainless cap and is used for depth and liquid level, while the 25 psi part is a board mount absolute sensor with a silicone gel port.
Key Specifications
| Parameter | Digital absolute | Digital depth and liquid | Analog ratiometric |
|---|---|---|---|
| Pressure range | 0 to 25 psi, 0 to 250 kPa, 0 to 2.5 bar | 0 to 14 bar, 0 to 30 bar | 0 to 10 kPa, 0 to 700 kPa |
| Output | 24-bit over I2C or SPI | 24-bit over I2C or SPI | 0.2 V to 4.7 V, ratiometric to the 5 V rail |
| Accuracy | 0.25 percent of full scale best fit | 20 mbar over 0 to 6 bar, 100 mbar over 0 to 14 bar | 5 percent of full scale full span |
| Resolution | 24-bit counts, no missing codes | 0.2 mbar at the highest oversampling | set by the ADC behind it |
| Supply | 3.3 V | 1.8 V to 3.6 V | 5 V, 4.75 V to 5.25 V |
| Current | about 1.9 mW active at 160 samples per second | 0.6 uA in the lowest mode | 5 mA typical |
| Pressure type | absolute, gage | absolute | differential, gage |
| Package | SMT with a long or short port | 3.3 x 3.3 x 2.75 mm, O-ring seal | SIP or SMT with two ports |
Included Models and Order Codes
The order codes below are the sensors quoted most often for instrument manifolds, liquid level probes, leak test fixtures and air handling units. Give the pressure range, the type (absolute, gage or differential), the media, the supply available and the interface, and the sensor and its seal are confirmed together.
| Part Number | Pressure Range | Type | Output | Accuracy | Package |
|---|---|---|---|---|---|
| MPRLS0025PA00001A | 0 to 25 psi (1.72 bar) | absolute | I2C, 24-bit | 0.25 percent of full scale best fit | SMT, long port, silicone gel |
| MS5837-30BA | 0 to 30 bar | absolute | I2C, 24-bit | 100 mbar over 0 to 20 bar, 200 mbar over 0 to 30 bar | 3.3 x 3.3 x 2.75 mm, stainless cap |
| MS5803-14BA | 0 to 14 bar | absolute | I2C and SPI, 24-bit | 20 mbar over 0 to 6 bar, 100 mbar over 0 to 14 bar | 3.3 x 3.3 x 2.75 mm, gel filled |
| MPX5700AP | 0 to 700 kPa | absolute | 0.2 V to 4.7 V analog | 2.5 percent of full scale | SIP, single port |
| MPX5010DP | 0 to 10 kPa | differential | 0.2 V to 4.7 V analog | 5 percent of full scale | SIP, dual port |
Key Features
Band kept with the number – an accuracy figure is always printed with the pressure band and the temperature band it belongs to, because a 20 mbar figure over 0 to 6 bar says nothing about the top of a 14 bar range.
Calibrated at the maker – the digital parts carry their own coefficients in a PROM, so the board does not need a pressure chamber at the test bench, only the coefficient read at start up.
Oversampling as a setting – conversion time and resolution trade against each other in the same part, from 0.2 mbar at the slowest setting to 1 mbar at the fastest, which is chosen per application.
Wet media options – gel filling and an antimagnetic stainless cap are listed as separate rows, so a part for a water tank is never mixed with a part for dry air in the same bill of materials.
Ratiometric analog output – the 0.2 V to 4.7 V parts scale with the supply, which keeps the reading stable when the ADC uses the same rail as its reference.
Low standby current – the depth sensor draws 0.6 uA in its lowest mode, which matters for a battery powered logger that samples once a minute.
Port and seal stated – the port length, the O-ring size and the wetted material are part of the order code, because a sensor that fits the manifold but seals on the wrong face leaks in the field.
Fault flags on the digital bus – the digital parts report an open or shorted bridge and a stale conversion, so a controller can tell a zero reading from a failed sensor.
Applications
These sensors are quoted for equipment that measures a real medium rather than a bench supply, typically where: The sensor is mounted on a control board inside the enclosure, so it is quoted with the SUPERB PCB and the SUPERB PCBA build for that board.
Liquid level and depth – a tank or a buoy measures head pressure, and a 14 bar or 30 bar gel filled part with a stainless cap gives 0.2 mbar resolution, which is 2 mm of water.
Leak and flow test fixtures – a differential part across an orifice reads a few kPa, and the ratiometric output is sampled by the same ADC that drives the valve, so the fixture needs no separate reference.
Medical pumps and ventilators – a 25 psi absolute sensor with a silicone gel port is used for line pressure, and its digital output removes the analog front end from the disposable assembly.
Compressors and pneumatic panels – a 700 kPa gage part with a 0.2 V to 4.7 V output feeds a controller ADC directly, and the 5 percent full scale error is acceptable because the trip point is set well inside the range.
Sourcing and Cross-Reference
A pressure sensor is usually the last part to be changed in a mechanical assembly, because the port, the O-ring and the height above the manifold are fixed by the housing. A cross reference therefore starts from the mechanical interface and works back to the electrical one: the same pressure type, the same range, the same port, and only then the same output format. A digital part cannot drop into a socket that was wired for a ratiometric analog part without a board change, even when the pressure range matches exactly.
Status matters more here than in most families. Several of the analog manifold sensors have been in production for fifteen years and carry an end of life notice while stock in the channel lasts. For those, the equivalent is chosen by the pressure range and the port, and the electrical interface is re-checked, because a replacement with a digital output changes the firmware as well as the board.
The third point is the calibration certificate. A medical or a custody transfer application usually needs the accuracy of the individual part, not the datasheet limit, so the quotation states whether the lot is supplied with a test record and at which pressure points it was taken.
For volume builds, SUPERB Assembly support covers the O-ring placement, the port torque and the reflow profile the gel filled parts need to keep their seal.
Q: Can you supply a replacement for an obsolete manifold pressure sensor with the same port and range?
A: Yes. Send the current part number, the pressure range, the type, the port drawing and the medium, and the SUPERB Tech sales team will confirm the order code and the nearest part that keeps the manifold interface.
Why Buyers Source Pressure Sensors Through SUPERB
- Mechanical interface first: the port, the seal and the height are matched before the output format, so a substitute fits the manifold that already exists.
- Accuracy with its band: every accuracy figure carries the pressure and temperature band it was taken over, which is the only way to compare two parts honestly.
- Wet and dry separated: gel filled and stainless capped parts are quoted as separate lines, so a part for water is never substituted into a dry air manifold.
- End of life cover: long running manifold parts are flagged with the equivalent that keeps the port, before a service depot runs out of a sensor it has used for years.