A load cell, a pressure capsule or a thermocouple produces a signal in the millivolt range on top of a common mode level that moves. The converter that reads it has to resolve microvolts, reject the mains frequency, and do it with a gain that matches the small span. A delta-sigma converter does this by oversampling at a high rate and filtering the result, which trades speed for resolution in a way that suits a measurement rather than a signal chain.
The parts on this page split by data rate. The bridge parts run slowly and quietly: the ADS1232 offers two differential channels with gains of 1, 2, 64 and 128, a choice of 10 or 80 samples per second, and 17 nV of noise at 10 samples per second with a gain of 128, which is the resolution a 3 kg load cell with a 2 mV per volt output needs. The HX711 is the same idea in a smaller package, with 10 or 80 samples per second, a gain of 128 or 64 on channel A, a fixed gain of 32 on channel B, and an on chip regulator that also powers the bridge.
The wideband parts trade that noise for speed. The ADS1256 gives eight channels through a multiplexer, a gain of 1 to 64, 30 kSPS, 23 bits of noise free resolution at the slowest rate, and 0.0010 percent of nonlinearity, in a SSOP-28. The AD7124-8 combines eight differential inputs, a gain stage to 128, simultaneous 50 Hz and 60 Hz rejection at 25 samples per second, and three power modes that move from 255 microamps at 2.4 kSPS to 930 microamps at 19.2 kSPS, which is what a battery instrument with a fast channel scan needs.
Key Specifications
| Parameter | Bridge and weigh scale parts | Wideband multiplexed parts |
|---|---|---|
| Resolution | 24 bit, no missing codes | 24 bit, no missing codes at all data rates and gains |
| Channels | 2 differential on ADS1232 and HX711 | 8 single ended or 4 differential on ADS1256; 8 differential or 15 single ended on AD7124-8 |
| Data rate | 10 or 80 samples per second | 2.5 samples per second to 30 kSPS on ADS1256; 1.17 to 19,200 samples per second on AD7124-8 |
| Gain | 1, 2, 64, 128 on ADS1232; 64 and 128 on channel A of HX711 | 1 to 64 on ADS1256; 1 to 128 on AD7124-8 |
| Noise | 17 nV at 10 samples per second with a gain of 128 on ADS1232 | 23 bits noise free at the slowest rate on ADS1256; 24 nV root mean square at a gain of 128 on AD7124-8 |
| Line rejection | Simultaneous 50 Hz and 60 Hz rejection on HX711 | Simultaneous 50 Hz and 60 Hz rejection at 25 samples per second on AD7124-8 |
| Nonlinearity | Not specified to the same level | 0.0010 percent maximum on ADS1256 |
| Interface | Two wire serial with a clock line | SPI on ADS1256 and AD7124-8 |
| Supply | 2.6 V to 5.5 V on HX711 | 5 V analog and 1.8 V to 3.6 V digital on ADS1256 |
Included Models and Order Codes
The codes below cover weigh scales, pressure and force sensors, temperature measurement and multi channel data loggers. State the channel count, the full scale signal, the source impedance, the required data rate and the mains frequency, and the part and the package are confirmed.
| Part Number | Channels | Data Rate | Gain | Package |
|---|---|---|---|---|
| ADS1232IPW | 2 differential | 10 or 80 samples per second | 1, 2, 64, 128 | TSSOP-24 |
| ADS1234IPW | 4 differential | 10 or 80 samples per second | 1, 2, 64, 128 | TSSOP-28 |
| HX711 | 2 differential | 10 or 80 samples per second | 64 or 128 on channel A, 32 on channel B | SOP-16 |
| ADS1256IDBR | 8 single ended, 4 differential | 2.5 samples per second to 30 kSPS | 1 to 64 | SSOP-28 |
| ADS1255IDBR | 2 single ended, 1 differential | 2.5 samples per second to 30 kSPS | 1 to 64 | SSOP-20 |
| AD7124-8BCPZ | 8 differential, 15 single ended | 1.17 to 19,200 samples per second | 1 to 128 | LFCSP-32 |
Key Features
Noise floor that suits a bridge – 17 nV at 10 samples per second with a gain of 128 on the ADS1232 resolves the 2 mV per volt output of a 350 ohm load cell to better than one part in 50,000.
Mains rejection without a notch filter – simultaneous 50 Hz and 60 Hz rejection at 25 samples per second means one firmware build works in both line frequencies, which removes a setting from production.
Eight channels on one die – the ADS1256 multiplexes eight inputs into one converter with 23 bits noise free at the slowest rate, so a logger with eight sensors needs one part and one calibration.
Gain stage in front of the converter – a gain of 128 on the AD7124-8 lifts a thermocouple or a shunt signal above the noise of the converter without an external amplifier and its drift.
Three power modes – the AD7124-8 moves from 255 microamps to 930 microamps with the data rate, which lets a battery instrument scan fast when awake and slow when idle.
Regulator and oscillator on chip – the HX711 powers the bridge from its own regulator and runs from its internal oscillator, so a scale needs one part, four wires and no crystal.
Applications
These converters are quoted for instruments that measure a small analog quantity, typically where: A converter is quoted with the SUPERB PCB and the SUPERB PCBA build for the same instrument board, so the reference, the input filter and the guard ring are reviewed with the converter.
Weigh scales and force measurement – a platform scale or a press force sensor needs 10 samples per second, a gain of 128 and a reading that does not drift with the line frequency, which is the ADS1232 and HX711 case.
Pressure and flow transmitters – a 4 mA to 20 mA transmitter has to resolve a small span over a wide temperature range, so the offset drift and the noise at the slowest rate decide the part.
Multi channel data loggers – eight thermocouples or strain gauges scanned into one converter need a multiplexer, a gain stage and a fast first sample, which is what the ADS1256 and AD7124-8 provide.
Sourcing and Cross-Reference
A converter is qualified with the sensor, the filter and the calibration in front of it, so a replacement has to match the resolution at the rate that is actually used, the gain range, the reference, and the settling of the input multiplexer. Two parts with the same 24 bit label can differ by a factor of ten in noise at 10 samples per second, and a part with a different reference input will not use the reference that is already on the board. We quote the channels, the data rate, the gain, the noise at that rate and the package on every line.
The reference and the input filter are usually the parts that decide whether the new converter meets the old specification. A 2.5 V reference with 5 ppm per degree drift, a differential filter matched to the new input capacitance, and a clock that keeps the notches on 50 Hz and 60 Hz are quoted as one set, so the resolution in the data sheet is the resolution on the board.
SUPERB Assembly support covers the reflow of the TSSOP, SSOP and LFCSP packages and the cleaning that keeps leakage away from the high impedance inputs.
Q: Can you supply a 24 bit converter that keeps the same noise at the data rate we use?
A: Yes. Send the channel count, the full scale signal, the data rate and the mains frequency, and the SUPERB Tech sales team will confirm the order code and the nearest part with the same noise at that rate.
Why Buyers Source Precision ADCs Through SUPERB
- Noise quoted at the rate used: the noise figure is given at the data rate the instrument runs, not only at the slowest setting, so the resolution claim can be checked.
- Reference and filter as one set: the reference, the input filter and the clock are quoted with the converter, so the drift and the notches belong to parts that will be fitted.
- Mains frequency handled: 50 Hz and 60 Hz rejection is confirmed per part, which removes a firmware variant from a product that ships to both markets.
- Package and pitch support: SSOP, TSSOP and LFCSP parts are placed and inspected on the same line that supplies them.
Related Product Families