Contact Us
  • Home
  • COMPONENTS
  • Temperature and Humidity Sensors for Environmental Monitoring

Temperature and Humidity Sensors for Environmental Monitoring

Capacitive humidity sensing elements with an on chip temperature sensor and I2C output. Typical RH accuracy from 0.5 percent on the HDC3020 to 2 percent on the SHTC3. Average current from 0.4 microamp, which suits a battery logger sampling once a minute. Packages from 1.5 by 1.5 mm, with filter membranes for condensing environments.
quote now

Product Specifications

Product Overview

A humidity reading is a capacitance measurement with a long memory. The polymer layer that absorbs water also absorbs contamination, and the offset that follows an exposure to 85 percent RH at 85 C can be several percent for days. That is why the parts on this page are chosen by three numbers rather than one: the accuracy band, the long term drift and whether the package can be washed or has to be protected. A sensor that is 2 percent accurate out of the box and drifts 1 percent a year is worse for a cold chain logger than a 1.5 percent part that holds its calibration.

The 2 percent group covers most building, appliance and instrument work. The SHT30, SHT31 and SHTC3 all specify a typical 2 percent RH and 0.2 C, with the SHT3x family running from 2.4 V to 5.5 V and the SHTC3 from 1.62 V to 3.6 V in a 2 by 2 by 0.75 mm DFN. The HDC1080 offers the same 2 percent with a 100 nA sleep current and a 1.3 microamp average at one sample per second, in a 3 by 3 mm package that is easy to route on a two layer board.

The precision group is where the difference shows. The SHT35 is specified at 1.5 percent RH and 0.1 C, the SHT40 at 1.8 percent and 0.2 C, the SHT45 at 1.0 percent and 0.1 C, and the HDC3020 at 0.5 percent typical between 10 and 50 percent RH with an offset correction register that brings a drifted part back inside its band. The HDC3020 also carries a heater for condensation, a 0.19 percent per year drift figure and a 4 s response, and the HDC3022 version adds a permanent IP67 membrane so the sensor can be washed with the board.

Key Specifications

ParameterStandard accuracy partsPrecision and protected parts
RH accuracy, typical2 percent RH from 20 to 80 percent RH0.5 to 1.5 percent RH in the 10 to 70 percent band
Temperature accuracy0.2 C typical0.1 C typical
Operating range0 to 100 percent RH, -40 to 125 C on SHTC30 to 100 percent RH, -40 to 125 C
Supply range1.62 V to 5.5 V depending on part1.08 V to 5.5 V depending on part
Average current0.7 to 1.3 microamp at one sample per second0.4 to 0.9 microamp depending on mode
InterfaceI2C, up to 400 kHzI2C, up to 1 MHz with four addresses
Drift0.25 percent RH per year typical0.19 percent RH per year typical
PackageDFN 2 by 2 mm, WSON 3 by 3 mmWSON 2.5 by 2.5 mm with optional IP67 cover

Included Models and Order Codes

The table lists the order codes most often quoted for loggers, HVAC controls, incubators and handheld meters. State the accuracy band, the supply rail, the sampling rate and whether the board is washed or coated, and the part and its packing are confirmed.

Part NumberRH AccuracyTemperatureSupplyCurrentPackage
SHT30-DIS-B2 percent RH typical0.2 C from 0 to 65 C2.4 V to 5.5 V600 microamp measuring, 0.2 microamp sleepDFN-8, 2.5 by 2.5 mm
SHT31-DIS-B2 percent RH typical0.2 C from 0 to 90 C2.4 V to 5.5 V600 microamp measuring, 0.2 microamp sleepDFN-8, 2.5 by 2.5 mm
SHT35-DIS-B1.5 percent RH typical0.1 C from 20 to 60 C2.4 V to 5.5 V600 microamp measuring, 0.2 microamp sleepDFN-8, 2.5 by 2.5 mm
SHT40-AD1B-R31.8 percent RH typical0.2 C from 0 to 75 C1.08 V to 3.6 V0.4 microamp average at one per secondDFN-4, 1.5 by 1.5 mm
SHT45-AD1B-R31.0 percent RH typical0.1 C from 0 to 75 C1.08 V to 3.6 V0.4 microamp average at one per secondDFN-4, 1.5 by 1.5 mm
SHTC32 percent RH typical0.2 C typical1.62 V to 3.6 V0.4 microamp average, 1 microamp measuringDFN-4, 2 by 2 by 0.75 mm
HDC1080DMBR2 percent RH typical0.2 C typical2.7 V to 5.5 V1.3 microamp average at one per secondWSON-6, 3 by 3 mm
HDC3020DEFR0.5 percent RH typical, 2.0 percent max0.1 C typical, -40 to 125 C1.62 V to 5.5 V0.4 microamp average, 99 microamp activeWSON-8, 2.5 by 2.5 mm
HDC3022DEFR0.5 percent RH typical, IP67 cover0.1 C typical, -40 to 125 C1.62 V to 5.5 V0.4 microamp average, integrated heaterWSON-8, 2.5 by 2.5 mm

Key Features

Accuracy stated as a band – the tolerance is quoted over a named humidity window, because a 2 percent part is often 4 percent at the ends of the range and that is where a drying application runs.

Calibration held in the part – each sensor is trimmed at test and the coefficients sit in on chip memory, so no calibration step is needed on the production line.

Current that suits a battery – 0.4 to 1.3 microamp average at one sample per second is small enough to run from a coin cell for the life of the product.

Offset correction – the HDC3020 keeps a correction register and a heater, which is how a sensor exposed to condensation is brought back inside its accuracy band without being replaced.

Washable options – the HDC3021 has removable tape for conformal coating and the HDC3022 has an IP67 membrane, so the sensor survives the process rather than being kept off the board.

Digital output – I2C with a CRC on every reading removes the analogue front end, the reference and the calibration channel that a thermistor and a capacitive element would need.

Applications

These sensors are quoted for equipment that has to hold a humidity window, typically where: A sensor board is normally quoted with the SUPERB PCB and SUPERB PCBA work we support for the same assembly, so the sensor, the cover and the coating sequence are handled as one build.

Cold chain and transport loggers – a logger that samples every few minutes needs 1 percent class accuracy, NIST traceability and an average current low enough to run for a year on one cell.

Incubators, dryers and HVAC – a controlled chamber needs the sensor to survive condensation and to recover its calibration after a wash, which is what the protected packages are for.

Handheld meters and air quality monitors – a 1.5 or 2 mm package fits beside the pressure sensor on a small board, and I2C keeps the pin count down when several sensors share the bus.

Sourcing and Cross-Reference

Humidity sensors are the part of a BOM most often changed without a full requalification, and that is usually a mistake. Two parts with the same footprint can differ by a factor of three in drift, in whether they need a rehydration step after reflow, and in the temperature they tolerate during board wash. We quote the accuracy band, the drift figure and the assembly handling note on the confirmation, so a second source is compared on behaviour rather than on pin count.

The rest of the chain decides whether the reading is believable: a membrane or a filter cap over the opening, a thermal break from the power components, and a potting compound that does not outgas onto the polymer. We quote the sensor with its cover and the gasket that goes with it, and where a board is built in volume the placement and coating sequence is agreed before the first lot.

Where the sensor boards are built in volume, SUPERB Assembly support covers the SMT placement, the wash and the coating steps that the humidity element is sensitive to.

Q: Do you supply humidity sensors that can be washed and coated on the board?

A: Yes. Send the accuracy band, the supply rail, the sampling rate and whether the board is washed or coated, and the SUPERB Tech sales team will confirm the order code, the protective option and the packing.

Why Buyers Source Humidity Sensors Through SUPERB

  1. Accuracy band on the quote: the RH window, the drift per year and the temperature accuracy are stated per line, so a replacement is compared on the number that decides the application.
  2. Protective option specified: tape, membrane or open cavity is chosen with the assembly process in mind, which avoids a sensor that is accurate in the lab and offset after coating.
  3. Traceability: NIST traceable parts are held with their lot and date code, which is what a cold chain or a medical customer asks for at audit.
  4. Board build: the placement, wash and bake sequence is agreed before the first lot, so the sensor is not exposed to a process it was not rated for.

Related Product Families

This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Sensors and detectors, Barometric pressure and altitude sensors, Six axis IMU sensors, 16 bit SAR ADCs, Component lead time solutions.