Enclosure Door Stays and Retaining Clips
Product Specifications
Product Overview
A door stay is a small part that decides how a cabinet is used. Without one, a 1800 mm door on a hinge swings past the open position, pulls the hinge screws, and in a walkway becomes an obstruction at head height. With one, the door holds at a fixed angle while a fitter works with both hands inside the cabinet.
The simple stay is a folding link between the door and the frame, fitted at the top of the enclosure and fixed without machining on the AE and VX families. The escape route stay is a different part: it holds the door open in normal use and releases automatically when pressure is applied, so a person leaving the room cannot be trapped by a door that was propped open. It is used together with 180 degree hinges so the door can swing both ways.
The third family is the door stop. It does not hold the door at an angle; it stops the door before it reaches the wall or the next cabinet, and it is the part for a wall mounted enclosure where a stay has nothing to reach. Width matters here: a stop needs a minimum enclosure width to have something to mount to, and a 300 mm wide box is the usual lower limit for a drilling type.
Key Specifications
| Type | Function | Fits | Fixing | Pack | Material |
|---|---|---|---|---|---|
| Door stay, folding link | holds the door open | AE and AE stainless enclosures | no machining, top mounted | 5 pieces | steel, zinc plated |
| Door stay for escape routes | holds open, releases under pressure | VX enclosures | with 180 degree hinges | 1 piece | steel, 0.25 kg |
| Door stay for escape routes | holds open, releases under pressure | TS, VX SE and PC enclosures | with 180 degree hinges | 1 piece | steel, 0.36 kg |
| Door and panel stop | stops the door at a set angle | modular polyester wall mounted, from 750 mm width | no machining | 1 piece with fixings | steel, plated |
| Door stop, wall mounted | stops the door at a set angle | wall mounted, from 300 mm width | drilling required, top or bottom | 1 piece with fixings | steel, plated |
| Large door stop kit | holds the door at 90 degrees | large mild and stainless enclosures | top or bottom of the opening | 1 kit | plated steel |
Included Models and Order Codes
The code alone does not tell you which enclosure the stay fits, so the table keeps the family in the description. The AE stay is a pack of five and is the one that covers a batch of small cabinets; the VX and TS escape route stays are single pieces because they are fitted where a walkway passes the door.
| Part number | Family | Holds open | Fits | Pack |
|---|---|---|---|---|
| 2519.000 | SZ door stay | open position, top mounted | AE, AE stainless | 5 pieces |
| 8618425 | SZ door stay for escape routes | releases under pressure | VX | 1 piece |
| 4583500 | SZ door stay for escape routes | releases under pressure | TS, VX SE, PC | 1 piece |
| UDS01 | Hoffman door and panel stop | set open angle | modular polyester from 750 mm width | 1 piece |
| ADO | Hoffman door stop | set open angle | wall mounted from 300 mm width | 1 piece |
| Door stop kit, large | Hoffman kit | 90 degrees | large mild and stainless enclosures | 1 kit |
Which Stay for Which Door
The choice is made on the door weight, the swing and what is behind the door, not on the cabinet series alone. This is the short version.
| Door and location | Stay type | Reason |
|---|---|---|
| AE cabinet, door up to 180 degrees | 2519.000 | folding link, fixed without machining |
| VX cabinet beside a walkway | 8618425 | releases under pressure, door opens both ways |
| TS or PC cabinet in a plant room | 4583500 | same release, bracket for the older frame |
| Wall mounted box, 400 mm wide | ADO | drilling type, fits from 300 mm width |
| Modular polyester box, 800 mm wide | UDS01 | no machining, mounts on door and body |
| Large free standing door, 90 degrees | large door stop kit | holds at 90 and keeps Type 4 and 12 |
Key Features
Fixed without machining on AE and VX – the stay is screwed to the door and the frame with the parts in the pack, so a retrofit does not need the cabinet to be stripped.
Escape route release – the special stay releases the door when pressure is applied, which keeps a walkway clear without locking the door open.
Packs that match the job – five pieces for a batch of small cabinets, single pieces for a walkway door.
Door stops for wall mounted boxes – where a folding stay has nothing to reach, a stop fixes the angle against the body.
Type 4 and Type 12 maintained – the large door stop kit is installed without breaking the enclosure rating when it is fitted as instructed.
Steel and plated finishes – zinc plated or plated steel parts, so the stay does not become the first rust point on a painted door.
Applications
Door stays are chosen by where the door opens, not by the cabinet size. Three cases.
Cabinets along a walkway – an escape route stay on every door that opens into the aisle, so a propped door releases instead of blocking the way.
Maintenance points opened daily – a folding stay on the AE door, so the fitter has both hands free at the terminal rail.
Wall mounted boxes in a corridor – a door stop rather than a stay, because the door has to stop before it reaches the wall.
Door stays and interlock switches are ordered with the hinges and locks for the same door, and both the SUPERB PCBA and the SUPERB PCB are checked against the panel wiring schedule so the safety circuit and the door hardware arrive together.
Sourcing and Cross-Reference
Check the hinge first. An escape route stay is specified with 180 degree hinges; fitted to a standard hinge the door cannot swing both ways and the release does nothing. Order the hinge and the stay as one pair.
Take the door weight into account. A folding link sized for a 600 mm door is not the part for a 1200 mm door with a window; the larger door needs the kit type, not the small stay.
Decide whether the door is to be held or stopped. A stay holds an angle and a stop limits travel. In a corridor the stop is usually the right part, because a held door is still an obstruction.
Fit after painting. A stay fitted to bare metal before the cabinet is painted has to come off again, and the screw holes are then painted over. See lead time and availability when the stays ship with the cabinets.
The SUPERB Assembly team sets the actuator gap on the bench before the door is hung, because a tongue switch that is set after painting usually ends up too far from the actuator and trips on a slammed door.
Q: Does the escape route stay need a special hinge, and is the door stay supplied in a pack of five?
A: Yes. Send the door drawing with the hinge side, the opening angle and the control voltage; the SUPERB Tech team quotes the stay and the interlock with the actuator and the connector that match the door.
Why Builders Buy Door Stays From SUPERB
- Stay and hinge checked together: the escape route type is quoted with the 180 degree hinge it needs, so the door actually releases.
- Enclosure family stated per code: AE, VX and TS stays are kept apart, because the bracket differs even when the function is the same.
- Packs and single pieces: five piece packs for a batch, single pieces for one walkway door.
- Stops for wall mounted boxes: a stop is quoted where a stay cannot reach, instead of a stay that does not fit.
Related Product Families