TPS56121DQPR
Product Specifications
TPS56121DQPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS56121DQPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS56121DQPR 15 A, 14 V input buck with voltage mode feed-forward control
The TPS56121DQPR is a 4.5 V to 14 V, 15 A synchronous buck in a 22 pin PQFN, 5 mm by 6 mm, with NexFET power MOSFETs inside the package. Control is voltage mode with input feed-forward, which means the loop responds to an input step before the output has moved, and the compensation network on the external pins is what sets the crossover. For a 15 A stage on a 12 V bus, that is a control scheme with a long track record and a predictable loop.
Switching frequency comes in fixed options of 300 kHz, 500 kHz and 1 MHz, chosen by order code rather than by a resistor, which removes one variable from the bill. The reference is 600 mV at 1 per cent, so the output can go as low as 0.6 V at 15 A. Soft start is programmable, and prebiased output startup is supported.
The overcurrent scheme is the part that needs explaining. A resistor from ILIM to ground sets the limit, but the value is read at power up in a calibration cycle: the device measures the voltage on that pin and stores an internal OCP level. During operation the stored level is compared against the drop across the low side FET when it is on. That is RDS(on) sensing with the offset trimmed out at startup, which is more accurate than a fixed comparator and does not need a sense resistor.
Key parameters from the SLUSAH4D document
| Input range | 4.5 V to 14 V, aimed at a 12 V intermediate bus |
| Output current | Up to 15 A with integrated NexFET power MOSFETs in a Power Block arrangement |
| Output voltage | Down to 0.6 V, set by the feedback divider against a 600 mV reference |
| Reference accuracy | 600 mV at 1 per cent |
| Switching frequency | Fixed options of 300 kHz, 500 kHz and 1 MHz by order code |
| Control | Voltage mode with input feed-forward, external loop compensation |
| Current limit | ILIM resistor read during a power on calibration cycle, then compared against the low side FET drop |
| Package | 22 pin PQFN with PowerPAD, 5 mm by 6 mm, DQP body |
The calibration cycle and what it means at test
Because the OCP level is set at power up from the ILIM pin, a board that is hot plugged or reset in a brownout condition can start the calibration with a disturbed pin voltage. The document addresses the timing, but the practical rule is that the ILIM divider should be short and close to the pin, with no long trace picking up switching noise. A limit that reads 20 per cent high on one board out of a hundred is usually a placement issue on that pin rather than a device issue.
RDS(on) sensing also drifts with temperature, and the calibration only removes the offset at the moment of startup. A limit set for 25 degrees will trip at a higher current in a cold enclosure and a lower current when the FET is hot, which is why the limit has to be chosen against the hot condition.
Voltage mode feed-forward in practice
Feed-forward makes the ramp amplitude track the input voltage, so a 12 V to 1 V conversion and an 8 V to 1 V conversion have the same loop gain without a change in compensation. That is useful on a bus that varies, which a 12 V intermediate rail does. The price is that the compensation network is external and has to be computed against the output capacitor, so the part is not a drop in for a board that was tuned for a different output bank.
At 15 A and 500 kHz the inductor is typically 1 to 2 microhenry, and the output bank is a mix of ceramics and polymer. The document's compensation examples cover both, and copying one of them is faster than deriving the network from scratch.
Where this part fits
12 V intermediate bus converters, telecom line cards, industrial controllers and any 15 A stage where a fixed frequency and a predictable loop are worth more than a small part count. Our desk handles the second source and the drop in checks for this generation, see power management cross reference and pin to pin cross reference.
What to check before a purchase order
The DQP suffix is the 22 pin 5 by 6 mm PQFN, and the same family ships at three fixed frequencies under one product page, so the order code carries the frequency and the reel label is the only proof. Confirm the ILIM resistor value against the inductor saturation current, and confirm that the external compensation network matches the output bank on the current revision of the board.
See incoming inspection plan for the receipt check, and component lead time solutions when one frequency option is short and another is not.
Questions that come up on this part
Can the 1 MHz option be used in place of the 500 kHz option on the same board, is a common question. It can, if the inductor and the output bank were sized for 1 MHz and the compensation is re computed, which usually means a component change. The second question is whether the OCP level can be changed after assembly. Only by changing the ILIM resistor, since the level is read at each power up.