Contact Us

TPS564257DRLR

Brand: Texas Instruments
Texas Instruments TPS564257DRLR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS564257DRLR — Power Management & Signal Chain | Superb Automation

TPS564257DRLR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS564257DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS564257DRLR: 4 A synchronous buck, 3 V to 17 V input, forced continuous conduction

TPS564257DRLR is a 4 A synchronous step-down converter in a 1.6 mm by 1.6 mm six pin body in a SOT-563 body of 6 pins. This is the forced continuous conduction member of the TPS56425x family, so it keeps the same frequency and a low output ripple at every load instead of dropping into pulse skipping. That is the version to pick when the rail feeds an analogue block or a radio and the light load spectrum matters more than the last few per cent of efficiency.

Order code and package

TPS564257DRLRActive, SOT-5X3 six pin, 4000 pieces on a large reel, MSL-1-260C-UNLIM
Lead finishprinted as Call TI or Sn on the R row, so the finish has to be confirmed on the offer
TPS564252DRLRActive, the Eco-mode member, same body and reel
TPS564255DRLRActive, the out of audio mode member, same body and reel
Temperature rangeminus 40 to 125 degrees junction on every row

Electrical parameters that decide the application

Input voltage3 V to 17 V
Output voltage0.6 V to 10 V
Continuous current4 A
Reference0.6 V, plus or minus 1 per cent at 25 degrees, plus or minus 1.5 per cent over the full range
Switching frequency600 kHz fixed
High side and low side resistance55.0 milliohm and 24.3 milliohm
Quiescent current100 microamp
Soft start1.6 ms typical, fixed internally

Family variants and how they differ

TPS564252Eco-mode at light load, highest efficiency, larger light load ripple
TPS564255out of audio mode, avoids the switching tone that a ceramic capacitor can sing at
TPS564257forced continuous conduction, fixed frequency and low ripple at all loads, this order code
Compensationinternal, the D-CAP3 loop needs no external network
Bootstrapcapacitor integrated, one less component and easier single layer routing

Points to check before this part goes on a BOM

Forced continuous conduction is a choice with a cost and a benefit. The converter never stops switching, so the ripple at 10 mA looks like the ripple at 4 A and the loop behaves the same at every load. The cost is that the part keeps switching losses at no load, which shows up as a few milliamp of input current where the Eco-mode sibling would draw microamp.

600 kHz and 55 milliohm are a matched pair. At 600 kHz the switching loss is moderate, which allows a small inductor and still leaves the conduction loss dominated by the 55 milliohm high side switch. Raising the frequency for a smaller inductor would move the loss into the switch, and at 4 A that is the wrong trade in a six pin body.

1.6 ms of soft start is fixed and that is a limitation. There is no soft start pin on this body. A board that has to bring 4 A of capacitance up slowly, or that has to sequence against another rail, cannot stretch the ramp without adding a circuit in front. Boards that need a programmable ramp belong to the family members with the SS pin.

The 0.6 V reference sets the divider, and the tolerance splits in two. One per cent at 25 degrees and one and a half per cent over the full range means the room temperature calculation is not the worst case. A 1.2 V core rail computed with the 25 degree figure can sit outside its window on a cold morning.

17 V input headroom is the number that decides suitability. A 12 V bus with a transient to 15 V is inside the range. A 24 V industrial rail is not, and neither is a 12 V rail on a vehicle where load dump is present. The part is a 17 V device and no amount of derating changes that.

The lead finish row says Call TI or Sn. That is not a normal published finish. It means the addendum does not pin the finish down for the R suffix row. For a customer with a lead free declaration, or for a process with a whisker concern, the finish has to be confirmed on the actual offer rather than assumed from the part number.

97 per cent maximum duty cycle is what makes a 3 V to 2.5 V rail possible. It lets the part run almost as a pass element when the input is close to the output, which is useful at the bottom of a 3.3 V bus. It also means the loop is effectively out of regulation at that point, so the rail follows the input and anything downstream has to tolerate it.

The hiccup behaviour on undervoltage matters more than the current limit. Over current is limited cycle by cycle, undervoltage goes to hiccup, so a hard short produces bursts rather than a continuous bake. That is the behaviour a safety reviewer looks for on a 4 A rail inside a sealed box.

Four amp in a six pin body puts the thermal question on the board, not on the part. The 55 milliohm high side and 24.3 milliohm low side give a conduction loss the package has to pass into copper. Converting 12 V to 5 V the high side conducts for roughly 42 per cent of the period, so the switch alone carries about 0.4 W before switching loss. The same part on a four layer board with a ground plane runs cooler than on two ounce copper with a small landing area, and the current rating does not change between the two.

The sibling with out of audio behaviour exists for a reason. TPS564255 avoids the switching pattern that makes a ceramic output capacitor audible at light load. Where this rail sits next to a microphone, a headphone output or a piezo buzzer, the forced continuous member is the wrong choice below a few tens of milliamp and the audio member is the right one. All three members share a body and a reel, so the choice is about behaviour rather than about supply.

What the six pin body gives up

No power good output, so a sequencer has to sense the rail through a comparator or through the enable pin of the next converter.

No frequency synchronisation and no external compensation, which is what keeps the pin count at six and the solution at a handful of parts, at the cost of loop freedom.

Where this order code fits

It feeds 4 A point of load rails on 12 V and 5 V industrial boards, gateways and network equipment where the ripple has to look the same at 10 mA and at 4 A. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the How to Reduce Component Cost page.

Questions buyers ask

Can this part replace the Eco-mode version on an existing board? Pin for pin yes, all three members share the body and the reel. The difference is behaviour at light load, so the substitution is fine for a load that is always above a few hundred milliamp and wrong for a rail that has to sit idle and draw microamp.

How much output capacitance does it need? The D-CAP3 loop is built to work with low ESR ceramic output capacitors and no external compensation. The value comes from the transient requirement rather than from a stability minimum, so the data sheet recommendation should be followed and the transient checked at the real load step.

What happens at 4 A continuous in a warm enclosure? The conduction loss is set by the 55 milliohm high side switch and the low side resistance, and the six pin body has to pass that heat into the copper. The current rating is electrical, the junction temperature is what limits a real board, and the two only agree when the copper area is adequate.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.