TMP300BIDCKR
Product Specifications
TMP300BIDCKR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TMP300BIDCKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TMP300BIDCKR resistor programmable temperature switch with an analog output in SC70-6
The TMP300BIDCKR is a temperature switch rather than a temperature sensor. One external resistor sets the trip point, a second pin selects one of two hysteresis levels, and the open drain output changes state when the die crosses the threshold. The same die also brings out an analog output that moves at ten millivolts per degree with 750 millivolts at twenty five degrees, so the part works as a comparator with a fixed threshold and as a coarse thermometer at the same time. That combination is what makes it useful in a protection chain where a processor is too busy or too slow to poll a sensor.
The supply range is the unusual part of the specification: the device runs from 1.8 V to 18 V and the switch output is open drain, so it can pull down a rail that is higher than its own supply, up to half a volt above the supply. Quiescent current is printed at 110 microamps maximum across the whole temperature range, and the trip accuracy is plus or minus two degrees typical and plus or minus four degrees maximum from minus 40 to plus 125 C. The hysteresis pin selects five degrees when it is tied to ground and ten degrees when it is tied to the supply, which is the difference between a fan control loop that cycles quietly and one that chatters.
Key parameters taken from the TMP300BIDCKR document
| Function | resistor programmable temperature switch with an analog temperature output |
| Trip programming | RSET in kilohms equals ten times the quantity fifty plus the trip temperature in degrees, divided by three |
| Trip accuracy | plus or minus 2 C typical and plus or minus 4 C maximum from minus 40 to plus 125 C |
| Hysteresis | 5 C with the hysteresis pin at ground, 10 C with the pin at the supply |
| Output | open drain, CMOS logic family, 0.3 V maximum low level at 5 mA sink, 10 microamps leakage high |
| Analog output | 10 mV per degree, 750 mV typical at 25 C, plus or minus 2 C typical and plus or minus 5 C maximum accuracy |
| Analog output impedance | 210 kilohms, so the load has to be a high impedance input |
| Supply | 1.8 V to 18 V operating, 2.35 V to 18 V for the specified temperature range |
| Quiescent current | 110 microamps maximum over the full temperature range |
| Thermal | specified from minus 40 to plus 125 C |
| Package | SC70-6, body DCK, 2.00 by 1.25 mm, also offered in SOT-23-6 |
| Order code facts | TMP300BIDCKR, SC70 DCK 6 pins, 3000 pieces on a large reel, NIPDAU, Level-1-260C-UNLIM, minus 40 to plus 125 C, marking QWL, Active |
The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.
Where the numbers matter in a real build
The trip point is set by a resistor, and the resistor tolerance therefore lands directly on the temperature. The document prints the equation and states that the internal thin film resistor is trimmed at the factory so its own tolerance does not add error, which means the external resistor is the only contributor. A one percent resistor on a trip point of one hundred degrees moves the threshold by roughly one degree, and a five percent part moves it by five, so the bill of materials line for this resistor is a functional decision rather than a cost decision.
Hysteresis is where a temperature switch either works or makes a product feel broken. With five degrees of hysteresis a fan that starts at seventy degrees stops at sixty five, and in a warm enclosure the board can sit in that band and cycle the fan every few seconds. Ten degrees fixes the cycling and it also lets the enclosure run hotter before the fan starts, which may be unacceptable for the components inside. The right way to choose is to measure the actual rise and fall of the enclosure temperature in the product, not to take the default.
The analog output is a convenience, not a measurement channel. Its accuracy is printed wider than the trip accuracy, it has a 210 kilohm output impedance, and the transfer is ten millivolts per degree, so a twelve bit converter with a 3.3 V reference resolves about eight millidegrees per code but the part itself is only good to a few degrees. It is useful for a service mode that shows a trend, and it is not a substitute for a calibrated sensor when a product has to report a temperature to a user or to a regulator.
The A and B letters in this family are not interchangeable in status terms. The document prints the A rows as not recommended for new builds and the B rows as active, and the difference between them is the accuracy grade rather than the function. A product that was released years ago on the A row will keep working, and a new build should be released on the B row, which is the code on this page. The tube rows of both letters are printed as obsolete, so only the reel rows are live.
- Trip point measured on three units at the low, middle and high end of the printed accuracy window, with the resistor value from the equation.
- Hysteresis verified by sweeping the temperature up and down and recording the two switching points, not by reading a single value.
- Output low level with the real pull up and the real load current, because 0.3 V is only guaranteed at 5 mA.
- Quiescent current at both ends of the supply range, since the part is often powered from a rail that sags.
- Analog output loading: confirm the input it drives is high impedance, otherwise the reading sags.
- Response time to a step in temperature on the actual board, which depends on the copper around the package.
Which projects this part fits
This device is used as the last line of thermal protection in power supplies, DC to DC modules, battery chargers, LED drivers, motor control boards and small enclosures where a processor may hang. It also appears as a fan controller, as an over temperature cut off for a linear regulator, and as a heater control in instruments that have to hold a temperature. Because it needs no firmware and no bus, it survives a processor that has stopped responding, which is exactly the case a safety review asks about.
Questions that come up before a purchase order is released
Can the trip point be changed after the board is built?
Yes, if the resistor is a discrete part. The equation in the document gives the value for any trip temperature in the printed range, and 0603 or 0402 sizes make a late change cheap. Changing the trip point after a product is qualified still needs a functional retest, because the hysteresis and the analog output reference move with the same internal circuit.
How is the analog output different from a sensor with a digital interface?
It has no calibration data, no register set and no fault reporting. It is a voltage that follows the die temperature with a few degrees of accuracy and a limited drive capability. For a user visible temperature or a logged record, a digital sensor is the honest choice, and this output is best kept for a service mode or a coarse trend.
What supply does the switch output tolerate?
The open drain output is rated to half a volt above the supply rail, so a 3.3 V part cannot directly pull down a 12 V signal. A small signal transistor or a level shift resistor divider is needed in that case, and the divider has to be sized so the 5 mA sink current is still available at the low level the receiving circuit expects.
Is the A version still available?
The document prints the A rows as not recommended for new builds and the tube rows of both letters as obsolete, while the B rows are active. For an existing product the A part may still be procurable, and for a new build the B part on this page is the one to specify, both at the same package and pinout.
Does the part need a pull up resistor on the output?
Yes, because the output is open drain and can only sink current. The value is set by the required rise time and by the input current of whatever reads the signal. A 10 kilohm pull up to the local rail is a common starting point, and the document prints the leakage so the worst case low level can be calculated.
How SUPERB handles this line
We supply the TMP300BIDCKR on the original 3000 piece reel with date code and lot traceability, and we check the A or B letter before shipping because the two look identical in a bag and only one of them is recommended for a new build. For customers building a protection chain we quote the set resistor and the pull up on the same order, since both decide whether the threshold holds. The power management cross reference page covers the parts that sit next to this switch, and the incoming inspection plan page describes how we verify a switch whose whole function is one threshold.