ISO3082DWR
Product Specifications
ISO3082DWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO3082DWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO3082DWR: isolated half duplex RS-485 transceiver rated to 20 Mbps
ISO3082DWR is an isolated half duplex RS-485 transceiver in a SOIC body of 16 pins. It provides an isolated half duplex link to a TIA/EIA-485 or 422 bus at up to 20 Mbps, with 2500 V RMS of UL isolation and a 4000 V peak VDE rating, and it presents one eighth of a unit load so 256 nodes can share a bus. The DWR order code is the wide body 16-pin SOIC on a reel.
Order code and package
| Order code | ISO3082DWR |
| Package | 16-pin wide body SOIC, DW |
| Packing | tape and reel |
| Signalling rate | up to 20 Mbps |
| Isolation | 2500 V RMS per UL 1577, 4000 V peak basic per VDE 0884-17, 560 V peak working |
| Bus loading | one eighth unit load, 256 nodes |
| Duplex | half duplex |
| Protection | thermal shutdown, bus pin ESD protection |
Electrical parameters that decide the application
| Bus capacitance | 16 pF typical |
| Transient immunity | 50 kV per microsecond typical |
| Bus ESD | 12 kV human body model to GND2, 6 kV to GND1 |
| Logic inputs | 3.3 V inputs, 5 V tolerant |
| Failsafe | receiver output defined on bus open, short and idle |
| Thermal shutdown | outputs disabled above the internal junction limit |
Family variants and how they differ
| ISO3082 | half duplex, 20 Mbps, this order code |
| ISO3080 | full duplex, four wire bus |
| ISO3088 | half duplex variant of the same family |
| ISO1176 | 40 Mbps, Profibus qualified, 160 nodes |
Points to check before this part goes on a BOM
The half duplex arrangement shares two wires for transmit and receive, so the driver enable has to be released before the receiver can hear a reply. The release time is a firmware decision as much as a hardware one, and a bus that works at 9600 baud often fails at 1 Mbps because the enable is still on when the first reply bit arrives.
One eighth unit load allows 256 nodes, but the number that matters on a real segment is the termination and bias network. Two 120 ohm terminators already load the bus, and adding 256 nodes with 16 pF each is 4 nF against a cable that was specified for a fraction of that, so practical segments stop well short of the silicon limit.
The 2500 V RMS rating is a 60 second UL test and the 4000 V peak figure is the VDE basic insulation rating with 560 V peak working voltage. Working voltages above 560 V peak are outside the part regardless of which withstand number a customer quotes.
Thermal shutdown is included because the driver can be left enabled into a shorted segment. The part disables its outputs above the internal junction limit and recovers when it cools, which means a bus fault shows up as an intermittent link rather than as a permanently dead node.
The 20 Mbps rating assumes a short segment with controlled impedance. At 20 Mbps a bit is 50 ns and the transceiver's own transition times consume a large part of it, so a 100 m segment runs at a far lower rate in practice and the data sheet rate is a ceiling rather than a working speed.
Logic inputs tolerate 5 V while accepting 3.3 V thresholds, so the controller side can be either rail. Side two still needs its own isolated 5 V supply, and the isolated supply is what the bill of materials has to carry in addition to the transceiver.
Failsafe receiver behaviour defines the output on an open, shorted or idle bus. A network with no bias resistors relies on that behaviour, and a network with bias resistors relies on them instead, so the two arrangements should not be mixed on one segment.
Half duplex turnaround is a timing budget, not a firmware detail. The driver has to be disabled, the bus has to settle through the termination, and the receiver has to be enabled before the reply arrives. At 1 Mbps those three steps consume a large part of a byte time, and a protocol that replies immediately needs the enable released early.
The isolated side supply has to be present before the bus is driven. A transceiver that is powered from a rail that comes up after the controller can drive the bus low during power up, which on a multi node segment looks like a stuck dominant state until the rail settles.
Bus pin protection and isolation are separate ratings and both have to be met. The 12 kV human body model figure is a handling and cable discharge level at the connector, while the 2500 V RMS figure is the barrier. A surge that exceeds the bus pin rating damages the transceiver without ever stressing the barrier, and a barrier failure happens with the pins well inside their own rating.
Where this order code fits
It is used on isolated RS-485 links in motor drives, power meters, building controllers, remote input output modules and industrial data concentrators. Teams comparing it with a neighbouring part start from our CAN Bus Transceiver Selection page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
What is the difference between the ISO3082 and ISO3080? The ISO3080 is the full duplex member of the family with four bus wires, and the ISO3082 is the half duplex two wire version. They are not interchangeable on a board.
Does it need an isolated supply? Yes. The barrier isolates data, not power, so side two needs its own 5 V rail derived through a transformer driver or a module.
How many nodes can a segment carry? The part allows 256, but cable capacitance, termination and bias resistors usually set a much lower practical number.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.